Fracture resistance of glazed, full-contour ZLS incisor crowns

被引:34
|
作者
Schwindling, Franz Sebastian [1 ]
Rues, Stefan [1 ]
Schmitter, Marc [2 ]
机构
[1] Univ Hosp Heidelberg, Dept Prosthodont, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Univ Hosp Wurzburg, Dept Prosthodont, Wurzburg, Germany
关键词
Permanent dental restoration; Crowns; Ceramics; Fracture load; Lithium disilicate; Feldspar; ALL-CERAMIC CROWNS; LITHIUM-DISILICATE CROWNS; FIXED DENTAL PROSTHESES; IN-VITRO; MARGINAL ADAPTATION; CAD/CAM MATERIALS; CLINICAL-EVALUATION; ANTERIOR CROWNS; SINGLE CROWNS; CEMENTATION;
D O I
10.1016/j.jpor.2016.12.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the failure behaviour of zirconia-reinforced lithium silicate (Celtra Duo, DeguDent) with that of lithium disilicate (IPS e.max CAD, Ivoclar Vivadent) and feldspar (Mark II, VITA) ceramics. Methods: Three groups of sixteen glazed maxillary incisor crowns were produced. The inner surfaces of the crowns were etched, then luted to metal dies with self-adhesive cement. Single load-to-failure tests were performed before and after thermo-mechanical ageing. To simulate clinical conditions, the specimens were thermocycled (10,000 cycles between 6.5 degrees C and 60 degrees C) and underwent chewing simulation (1,200,000 cycles, F-max = 86 N). Statistical analyses were performed by use of non-parametric Kruskal-Wallis and Mann-Whitney U-tests. Results: Before ageing, all the monolithic incisor crowns fractured at test forces >285 N. Mean fracture loads were highest for zirconia-reinforced lithium silicate (725 N, SD 162 N), slightly lower for lithium disilicate (701 N, SD 276 N), and lowest for feldspar (554 N, SD 190 N). The differences between the results were not statistically significant. After ageing, fracture resistance decreased for all materials except zirconia-reinforced lithium silicate. Mean fracture loads were highest for zirconia-reinforced lithium silicate (766 N, SD 98 N) and significantly lower for both lithium disilicate (485 N, SD 64 N) and feldspar (372 N, SD 116 N). Conclusion: Monolithic restorations fabricated from zirconia-reinforced lithium silicate retain high fracture resistance after extensive thermo-mechanical ageing. This preclinical study suggests that cohesive failures of monolithic anterior crowns produced of these ceramics will not be a major problem in dental practice. (C) 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [1] Fracture Resistance of a Selection of Full-Contour All-Ceramic Crowns: An In Vitro Study
    Zesewitz, Tim F.
    Knauber, Andreas W.
    Nothdurft, Frank P.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (03) : 264 - 266
  • [2] In vitro performance of full-contour zirconia single crowns
    Beuer, Florian
    Stimmelmayr, Michael
    Gueth, Jan-Frederik
    Edelhoff, Daniel
    Naumann, Michael
    [J]. DENTAL MATERIALS, 2012, 28 (04) : 449 - 456
  • [3] Different Designs of Deep Marginal Elevation and Its Influence on Fracture Resistance of Teeth with Monolith Zirconia Full-Contour Crowns
    Robaian, Ali
    Alqahtani, Abdullah
    Alanazi, Khalid
    Alanazi, Abdulrhman
    Almalki, Meshal
    Aljarad, Anas
    Albaijan, Refal
    Maawadh, Ahmed
    Sufyan, Aref
    Mirza, Mubashir Baig
    [J]. MEDICINA-LITHUANIA, 2023, 59 (04):
  • [4] In vitro failure and fracture resistance of veneered and full-contour zirconia restorations
    Preis, Verena
    Behr, Michael
    Hahnel, Sebastian
    Handel, Gerhard
    Rosentritt, Martin
    [J]. JOURNAL OF DENTISTRY, 2012, 40 (11) : 921 - 928
  • [5] Effect of the bonding strategy on the tensile retention of full-contour zirconia crowns
    [J]. Bottino, Marco C. (mbottino@umich.edu), 1600, Elsevier Ltd (85):
  • [6] Effect of the bonding strategy on the tensile retention of full-contour zirconia crowns
    Feitosa, Sabrina A.
    Campos, Fernanda
    Yoshito, Walter Kenji
    Lazar, Dolores R. R.
    Ussui, Valter
    Valandro, Luiz Felipe
    Bottino, Marco A.
    Bottino, Marco C.
    [J]. INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2018, 85 : 106 - 112
  • [7] Surface roughness of zirconia for full-contour crowns after clinically simulated grinding and polishing
    Rim Hmaidouch
    WolfDieter Mller
    HansChristoph Lauer
    Paul Weigl
    [J]. International Journal of Oral Science, 2014, (04) : 241 - 246
  • [8] Surface roughness of zirconia for full-contour crowns after clinically simulated grinding and polishing
    Hmaidouch, Rim
    Mueller, Wolf-Dieter
    Lauer, Hans-Christoph
    Weigl, Paul
    [J]. INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2014, 6 (04) : 241 - 246
  • [9] Surface roughness of zirconia for full-contour crowns after clinically simulated grinding and polishing
    Rim Hmaidouch
    Wolf-Dieter Müller
    Hans-Christoph Lauer
    Paul Weigl
    [J]. International Journal of Oral Science, 2014, 6 : 241 - 246
  • [10] Surface roughness of zirconia for full-contour crowns after clinically simulated grinding and polishing
    Rim Hmaidouch
    Wolf-Dieter Mller
    Hans-Christoph Lauer
    Paul Weigl
    [J]. International Journal of Oral Science, 2014, 6 (04) : 241 - 246