In vitro failure and fracture resistance of veneered and full-contour zirconia restorations

被引:70
|
作者
Preis, Verena [1 ]
Behr, Michael [1 ]
Hahnel, Sebastian [1 ]
Handel, Gerhard [1 ]
Rosentritt, Martin [1 ]
机构
[1] Univ Med Ctr Regensburg, Dept Prosthet Dent, D-93042 Regensburg, Germany
关键词
Zirconia; Full-contour; Surface treatment; Wear; Fracture resistance; FIXED-PARTIAL DENTURES; DENTAL PROSTHESES; Y-TZP; FRACTOGRAPHIC ANALYSES; SUBSTRUCTURE CERAMICS; LABORATORY SIMULATION; WEAR PERFORMANCE; BITE FORCE; STRENGTH; CROWNS;
D O I
10.1016/j.jdent.2012.07.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the failure and fracture resistance of zirconia-based fixed partial dentures (FPDs) under the influence of different surface treatments and adjustment procedures. Methods: Seven groups (n = 8/group) of three-unit zirconia-based FPDs were fabricated in anatomic design (AD) or anatomically reduced design (ARD) and surfaces were prepared according to clinical relevance: #1: AD - sintered; #2: AD - sintered - glazed; #3: AD - sintered - sandblasted - glazed; #4: AD - sintered - polished - grinded (contact points adjusted); #5: AD - sintered - polished - grinded - repolished; #6: ARD - sintered - veneered; #7: control: analogous to #3 but without thermal cycling (TC) and mechanical loading (ML). FPDs were adhesively bonded to polymethylmethacrylate abutment teeth. TCML (TC: 6000 x 5 degrees/55 degrees; ML: 1.2 x 10(6) x 50 N, 1.6 Hz) was conducted in a chewing simulator with steatite spheres as antagonists. Failures were monitored and fracture resistance was determined after ageing. Data were analysed statistically with Mann-Whitney U-test (Kolmogorov-Smirnov-test; alpha = 0.05). FPDs were subjected to scanning electron microscopy for fractographic failure analysis. Results: None of the FPDs failed during TCML, but showed wear at contact points. Median fracture force ranged between 1173.5 N (#4) and 1316.0 N (#3) without significant (p = 0.910) differences between the groups or in comparison to the control (p > 0.462). Conclusions: Zirconia restorations showed high resistance to failures and fracture under different surface treatment variations. Full-contour polished or glazed zirconia FPDs might be an alternative to common veneered restorations. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:921 / 928
页数:8
相关论文
共 50 条
  • [31] In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials
    Choi, Yu-Sung
    Kim, Sung-Hun
    Lee, Jai-Bong
    Han, Jung-Suk
    Yeo, In-Sung
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2012, 4 (03): : 162 - 169
  • [32] Comparative analysis on intaglio surface trueness, wear volume loss of antagonist, and fracture resistance of full-contour monolithic zirconia crown for single-visit dentistry under simulated mastication
    Kim, Yong-Kyu
    Yoon, Hyung-In
    Kim, Dae-Joon
    Han, Jung-Suk
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (03): : 173 - 181
  • [33] Effect of aging on fracture resistance and torque loss of restorations supported by zirconia and polyetheretherketone abutments: An in vitro study
    Ghodsi, Safoura
    Tanous, Michel
    Hajimahmoudi, Mohammadreza
    Mahgoli, Hoseinali
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 501.e1 - 501.e6
  • [34] Investigation of Fracture Resistance of Zirconia Restorations After Different Surface Treatments
    Akar, Turker
    Akin, Hakan
    [J]. CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2021, 11 (02): : 318 - 321
  • [35] Effect of Different Decontamination Methods on Fracture Resistance, Microstructure, and Surface Roughness of Zirconia Restorations-In Vitro Study
    Darwich, Rama A.
    Awad, Manal
    Abou Neel, Ensanya A.
    [J]. MATERIALS, 2023, 16 (06)
  • [36] Application of zirconia surface coating to improve fracture resistance and stress distribution of zirconia ceramic restorations
    Farhan, Firas Abdulameer
    Sulaiman, Eshamsul
    Kutty, Muralithran G.
    [J]. CERAMICS INTERNATIONAL, 2018, 44 (17) : 21633 - 21640
  • [37] Clinical guidelines for posterior restorations based on Coverage, Adhesion, Resistance, Esthetics, and Subgingival management The CARES concept: Part II - full-contour resistive crowns with vertical preparation
    Cardoso, Jorge Andre
    Venuti, Pasquale
    Almeida, Paulo Julio
    Costa, Raul
    Lapa, Hugo Costa
    Afonso, Luis
    [J]. INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2023, 18 (04): : 346 - 365
  • [38] Evaluation of Fracture Resistance and Sites of Failure of Different Dowel Core Restorations: An In-Vitro Study
    Guragain, Manjeev
    Mathema, Suraj
    Rokaya, Dinesh
    [J]. OPEN DENTISTRY JOURNAL, 2019, 13 : 454 - 461
  • [39] Effects of two grading techniques of zirconia material on the fatigue limit of full-contour 3-unit fixed dental prostheses
    Villefort, Regina Furbino
    Amaral, Marina
    Rocha Pereira, Gabriel Kalil
    Bastos Campos, Tiago Moreira
    Zhang, Yu
    Bottino, Marco Antonio
    Valandro, Luiz Felipe
    de Melo, Renata Marques
    [J]. DENTAL MATERIALS, 2017, 33 (04) : E155 - E164
  • [40] Fracture Resistance of Titanium-Based Lithium Disilicate and Zirconia Implant Restorations
    Roberts, Evan E.
    Bailey, Clifton W.
    Ashcraft-Olmscheid, Deborah L.
    Vandewalle, Kraig S.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (07): : 644 - 650