Results of the AcrySof Toric intraocular lenses implantation

被引:0
|
作者
Swiatek, Bozena [1 ]
Michalska-Malecka, Katarzyna [1 ]
Dorecka, Mariola [1 ]
Romaniuk, Dorota [1 ]
Romaniuk, Wanda [1 ]
机构
[1] Med Univ Silesia, Dept Ophthalmol, Univ Hosp 5, PL-40952 Katowice, Poland
来源
MEDICAL SCIENCE MONITOR | 2012年 / 18卷 / 01期
关键词
cataract; corneal astigmatism; toric intraocular lenses; ASTIGMATISM CORRECTION; ROTATIONAL STABILITY; OUTCOMES;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The expectations of post-removal cataract surgery patients are extremely high, and best vision acuily is expected. The best refractive results arc influenced by two factors cataract surgical removal and the corneal astigmatism correction. Currently, the two most often applied corneal astigmatism removal methods are laser surgery and toric intraocular lens implantation, with the latter method being both more stable and more reversible. This study aimed to estimate the surgical astigmatism correction efficiency after ActySof Toric intraocular lens implantation in patients with corneal astigmatism. Material/Methods: We used the AcrySof Toric IOL 1-part hydrophobic acrylic lenses. The retrospective research covered 30 eyeballs in 28 cataract and corneal astigmatism patients, with the AcrySof Toric lens implanted by one surgeon. Results: In our test group 92.31% of post-surgical patients (phacoemulsification and tone lenses implantation) gained the best uncorrected visual acuity, range 0.6-1.0; and in 7.69% of patients the acuity was 0.4-0.6. Lens rotation was examined three weeks after the surgical procedure and a 3.24+/-3.41 degree axial displacement was observed; however, this lens rotation was clinically unimportant. Based on the analysis of post-surgical results, the corneal astigmatism was 84.2% lower than before the procedure. Conclusions: We noticed clinically and statistically important vision acuity improvement in the corneal astigmatism patients. The patients' high satisfaction was conditioned by proper pre-surgery qualification. Astigmatism correction by cataract removal surgery is a safe and effective surgical solution. In the future, we expect the use of tonic intraocular lenses will become widespread and significant.
引用
下载
收藏
页码:PI1 / PI4
页数:4
相关论文
共 50 条
  • [1] Implantation of AcrySof acrylic intraocular lenses
    Shugar, JK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 1355 - 1359
  • [3] Comparison of the Visual Outcomes and OPD-Scan Results of AMO Tecnis Toric and Alcon Acrysof IQ Toric Intraocular Lenses
    Ferreira, Tiago B.
    Almeida, Ana
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (08) : 551 - +
  • [4] Comparison of visual function following implantation of Acrysof Natural intraocular lenses with conventional intraocular lenses
    Landers, John
    Tan, Teng-Han
    Yuen, Joshua
    Liu, Henry
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (02): : 152 - 159
  • [5] Clinical results of AcrySof intraocular lens implantation
    Mengual, E
    Garcia, J
    Elvira, JC
    Hueso, JR
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (01): : 114 - 117
  • [6] Results of Complicated Cataract Phacoemulsification with Implantation of Multifocal Intraocular Lenses ACRYSOF IQ RESTOR (ALCON)
    Zaharova, E. K.
    Poskachina, T. R.
    Nazarov, A. N.
    YAKUT MEDICAL JOURNAL, 2012, (01): : 187 - 191
  • [7] Refractive Results after Implantation of Toric Intraocular Lenses Using the Zeiss Callisto System
    Raemy, Kenji
    Scherrer, Mark
    Sturmer, Jorg Peter Egon
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023, 240 (04) : 421 - 425
  • [8] Factors influencing 1-year rotational stability of AcrySof Toric intraocular lenses
    Zhu, Xiangjia
    He, Wenwen
    Zhang, Keke
    Lu, Yi
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (02) : 263 - 268
  • [9] Toric intraocular lenses
    Auffarth, G. U.
    OPHTHALMOLOGE, 2007, 104 (12): : 1022 - 1023
  • [10] Implantation of toric intraocular lenses to correct high postkeratoplasty astigmatism
    Amm, M
    Halberstadt, M
    OPHTHALMOLOGE, 2002, 99 (06): : 464 - 469