Comparison of visual function following implantation of Acrysof Natural intraocular lenses with conventional intraocular lenses

被引:27
|
作者
Landers, John [1 ]
Tan, Teng-Han [1 ]
Yuen, Joshua [1 ]
Liu, Henry [1 ]
机构
[1] Orana Eye Ctr, Dubbo, NSW 2830, Australia
来源
关键词
blue-blocking; colour vision; contrast sensitivity; intraocular lens;
D O I
10.1111/j.1442-9071.2006.01434.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Recently an intraocular lens (IOL) has been introduced which blocks blue light. As blocking blue light may be to the patient's detriment, this study was designed to evaluate visual function following implantation of a blue-blocking (Acrysof Natural) IOL. Patients were recruited for this non-randomized controlled interventional study, from those attending a private rural ophthalmology clinic for cataract surgery (n = 93). Only those who had previously had a conventional IOL implanted into one eye were offered an Acrysof Natural IOL for the second eye. Postoperatively patients underwent refracted Snellen visual acuity, contrast sensitivity using a CSV-1000E instrument and colour vision testing using a Farnsworth D-15 test, with a subset (n = 20) undergoing a Farnsworth-Munsell 100-Hue test. Results were then compared between eyes. Finally, a subset (n = 63) completed a survey designed to assess the subjective impact of the Acrysof Natural IOL. There were no statistically significant differences between eyes implanted with conventional IOLs compared with Acrysof Natural IOLs for visual acuity (t = 0.57; P = 0.57), contrast sensitivity (t = 0.43; P = 0.67 for 3 cycles per degree [cpd], t = 0.56; P = 0.58 for 6 cpd, t = 0.09; P = 0.93 for 12 cpd and t = 0.16; P = 0.87 for 18 cpd) or colour vision with the Farnsworth D-15 (chi(2) = 0.38; P = 0.55) or the Farnsworth-Munsell 100-Hue test t = 0.34; P = 0.74). Most subjects reported that they could not tell a difference between the two IOLs subjectively or that any difference experienced was not significant. Our sample did not show any significant differences between eyes implanted with conventional IOLs and the Acrysof Natural IOL. We would suggest that the Acrysof Natural IOL may be used without any significant difference in visual function.
引用
下载
收藏
页码:152 / 159
页数:8
相关论文
共 50 条
  • [1] Implantation of AcrySof acrylic intraocular lenses
    Shugar, JK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 1355 - 1359
  • [2] Results of the AcrySof Toric intraocular lenses implantation
    Swiatek, Bozena
    Michalska-Malecka, Katarzyna
    Dorecka, Mariola
    Romaniuk, Dorota
    Romaniuk, Wanda
    MEDICAL SCIENCE MONITOR, 2012, 18 (01): : PI1 - PI4
  • [3] Effects on visual function of glistenings and folding marks in AcrySof intraocular lenses
    Gunenc, U
    Oner, FH
    Tongal, S
    Ferliel, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10): : 1611 - 1614
  • [4] Prevalence of Glistenings in Acrysof Intraocular Lenses
    Wittpenn, J. R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Visual performance following implantation of presbyopia correcting intraocular lenses
    Torky, Magda A.
    El Nokrashy, Amgad
    Metwally, Heba
    Abdelhameed, Ameera G.
    EYE, 2022, 39 (1) : 79 - 87
  • [6] IMPLANTATION OF INTRAOCULAR LENSES
    JACOBI, KW
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1978, 172 (02) : 226 - 226
  • [7] Comparison of visual outcomes and reading performance after bilateral implantation of multifocal intraocular lenses with bilateral monofocal intraocular lenses
    Özge Güngör Akkuş
    Ikbal Seza Petriçli
    International Ophthalmology, 2018, 38 : 1011 - 1019
  • [8] Comparison of visual outcomes and reading performance after bilateral implantation of multifocal intraocular lenses with bilateral monofocal intraocular lenses
    Akkus, Ozge Gungor
    Petricli, Ikbal Seza
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (03) : 1011 - 1019
  • [9] Comparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses
    Yamauchi, Tomofusa
    Tabuchi, Hitoshi
    Takase, Kosuke
    Ohsugi, Hideharu
    Ohara, Zaigen
    Kiuchi, Yoshiaki
    PLOS ONE, 2013, 8 (06):
  • [10] Contralateral comparison of visual outcome of AcrySof IQ and SA60AT intraocular lenses
    Habibollahi, Alireza
    Hashemi, Hassan
    Mehravaran, Shiva
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (03): : 259 - 263