Refractive Results after Implantation of Toric Intraocular Lenses Using the Zeiss Callisto System

被引:0
|
作者
Raemy, Kenji [1 ,3 ]
Scherrer, Mark [2 ]
Sturmer, Jorg Peter Egon [2 ]
机构
[1] Univ Zurich, Med Fak, Zurich, Switzerland
[2] Kantonsspital Winterthur, Augenklin, Winterthur, Switzerland
[3] Ifang 3, CH-8307 Effretikon, Switzerland
关键词
cataract; astigmatism; toric IOL; Zeiss Callisto; IMAGE-GUIDED SYSTEM; ALIGNMENT ACCURACY; ASTIGMATISM; OUTCOMES; SURGERY; MARKING;
D O I
10.1055/a-2013-2466
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background For cataract patients with astigmatism, the insertion of a toric intraocular lens is a safe and effective method to achieve emmetropia. The exact alignment of the lens along the calculated axis is essential for effective correction of astigmatism. The purpose of this study is to evaluate our own data using descriptive statistics. The primary focus is on the refractive outcome and thus the verification of the alignment accuracy of toric IOLs with the Zeiss Callisto system. Patients and Methods The study evaluated a total of 106 eyes of 72 patients who underwent cataract surgery with implantation of a toric intraocular lens at our hospital between January 2019 and December 2020. Preoperative biometry and intraoperative marking of the implantation axis was performed using the Zeiss Callisto system. Postoperative controls were performed after one day, one week and 4 weeks, either at our hospital or by the referring ophthalmologist. For the analysis, only the data of the 4-week control were used. Results In 64 eyes (60%), a Zeiss AT Torbi 709M or MP and in 42 eyes (40%) a PhysIOL Ankoris toric yellow IOL were implanted. In 46 eyes, postoperative uncorrected visual acuity was not recorded. Of the remaining 60 eyes, the mean postoperative uncorrected visual acuity was 0.07 +/- 0.12 logMAR. Postoperative uncorrected visual acuity >= 1.0 (decimal) was achieved in 48% of the eyes and visual acuity >= 0.6 (decimal) in 92%. The postoperative cylinder averaged - 0.65 +/- 0.53 D. The cylinder of the target refraction was - 0.45 +/- 0.39 D on average. The mean of the absolute value of the postoperative cylinder minus the cylinder of the target refraction was 0.42 +/- 0.32 D. Conclusions The Zeiss Callisto system is an effective tool to align toric intraocular lenses.
引用
下载
收藏
页码:421 / 425
页数:5
相关论文
共 50 条
  • [1] Refractive and Visual Outcomes After Implantation of a Secondary Toric Sulcus Intraocular Lenses
    Gundersen, Kjell Gunnar
    Potvin, Rick
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1337 - 1342
  • [2] Results of the AcrySof Toric intraocular lenses implantation
    Swiatek, Bozena
    Michalska-Malecka, Katarzyna
    Dorecka, Mariola
    Romaniuk, Dorota
    Romaniuk, Wanda
    MEDICAL SCIENCE MONITOR, 2012, 18 (01): : PI1 - PI4
  • [3] Refractive Outcomes for Toric Intraocular Lenses
    Simpson, Michael J.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) : 945 - 946
  • [4] Postoperative Refractive and Visual Acuity Outcomes Using Manual Ink Markings versus Callisto Markerless System for Toric Intraocular Lens Implantation
    Sambhara, Deepak
    Andrews, Hans
    Sudhakar, Shruti
    O'Rourke, Tara L.
    Wolford, Kevin
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [5] Comparison of visual and refractive outcomes after bilateral implantation of toric intraocular lenses with or without a multifocal component
    Hayashi, Ken
    Masumoto, Miki
    Takimoto, Minehiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01): : 73 - 83
  • [6] Refractive surprise after toric intraocular lens implantation: Graph analysis
    Alpins, Noel
    Ong, James K. Y.
    Stamatelatos, George
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (02): : 283 - 294
  • [7] Refractive Lens Exchange With Toric Intraocular Lenses in Keratoconus
    Jaimes, Martha
    Xacur-Garcia, Fiona
    Alvarez-Melloni, Diana
    Graue-Hernandez, Enrique O.
    Ramirez-Luquin, Tito
    Navas, Alejandro
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (09) : 657 - 663
  • [8] Visual Function After Implantation of Trifocal and Trifocal Toric Intraocular Lenses Using Intraoperative Aberrometry
    Brissette, Ashley
    Cole, Brigette
    Hall, Brad
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 1547 - 1554
  • [9] Clinical outcomes of Zeiss toric intraocular lens implantation for correction of corneal astigmatism after cataract
    Kamel, K.
    Dervan, E.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S14 - S14
  • [10] Clinical Outcomes After Phacoemulsification With Implantation of Trifocal and Toric Trifocal Intraocular Lenses
    Eldanasoury, Alaa
    Tolees, Sherif
    Bains, Harkaran S.
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (06) : 372 - 379