Refractive Results after Implantation of Toric Intraocular Lenses Using the Zeiss Callisto System

被引:0
|
作者
Raemy, Kenji [1 ,3 ]
Scherrer, Mark [2 ]
Sturmer, Jorg Peter Egon [2 ]
机构
[1] Univ Zurich, Med Fak, Zurich, Switzerland
[2] Kantonsspital Winterthur, Augenklin, Winterthur, Switzerland
[3] Ifang 3, CH-8307 Effretikon, Switzerland
关键词
cataract; astigmatism; toric IOL; Zeiss Callisto; IMAGE-GUIDED SYSTEM; ALIGNMENT ACCURACY; ASTIGMATISM; OUTCOMES; SURGERY; MARKING;
D O I
10.1055/a-2013-2466
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background For cataract patients with astigmatism, the insertion of a toric intraocular lens is a safe and effective method to achieve emmetropia. The exact alignment of the lens along the calculated axis is essential for effective correction of astigmatism. The purpose of this study is to evaluate our own data using descriptive statistics. The primary focus is on the refractive outcome and thus the verification of the alignment accuracy of toric IOLs with the Zeiss Callisto system. Patients and Methods The study evaluated a total of 106 eyes of 72 patients who underwent cataract surgery with implantation of a toric intraocular lens at our hospital between January 2019 and December 2020. Preoperative biometry and intraoperative marking of the implantation axis was performed using the Zeiss Callisto system. Postoperative controls were performed after one day, one week and 4 weeks, either at our hospital or by the referring ophthalmologist. For the analysis, only the data of the 4-week control were used. Results In 64 eyes (60%), a Zeiss AT Torbi 709M or MP and in 42 eyes (40%) a PhysIOL Ankoris toric yellow IOL were implanted. In 46 eyes, postoperative uncorrected visual acuity was not recorded. Of the remaining 60 eyes, the mean postoperative uncorrected visual acuity was 0.07 +/- 0.12 logMAR. Postoperative uncorrected visual acuity >= 1.0 (decimal) was achieved in 48% of the eyes and visual acuity >= 0.6 (decimal) in 92%. The postoperative cylinder averaged - 0.65 +/- 0.53 D. The cylinder of the target refraction was - 0.45 +/- 0.39 D on average. The mean of the absolute value of the postoperative cylinder minus the cylinder of the target refraction was 0.42 +/- 0.32 D. Conclusions The Zeiss Callisto system is an effective tool to align toric intraocular lenses.
引用
下载
收藏
页码:421 / 425
页数:5
相关论文
共 50 条
  • [21] Evaluation of Rotation and Visual Outcomes After Implantation of Monofocal and Multifocal Toric Intraocular Lenses
    Garzon, Nuria
    Poyales, Francisco
    Ortiz de Zarate, Begona
    Luis Ruiz-Garcia, Jose
    Antonio Quiroga, Juan
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (02) : 90 - +
  • [22] Implantation of toric intraocular lenses for correction of high corneal astigmatism after penetrating keratoplasty
    Viestenz, A
    Langenbucher, A
    Küchle, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U49 - U49
  • [23] Computerized calculation scheme for retinal image size after implantation of toric intraocular lenses
    Langenbucher, Achim
    Viestenz, Anja
    Seitz, Berthold
    Bruenner, Holger
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (01): : 92 - 98
  • [24] Implantation of toric intraocular lenses to correct high postkeratoplasty astigmatism
    Amm, M
    Halberstadt, M
    OPHTHALMOLOGE, 2002, 99 (06): : 464 - 469
  • [25] Tolerance to Residual Refractive Errors After Trifocal and Trifocal Toric Intraocular Lens Implantation
    Rementeria-Capelo, Laureano A.
    Contreras, Ines
    Garcia-Perez, Jorge L.
    Carrillo, Virginia
    Gros-Otero, Juan
    Ruiz-Alcocer, Javier
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2021, 47 (04): : 213 - 218
  • [26] Visual and Refractive Outcomes after Cataract Surgery with Implantation of a New Toric Intraocular Lens
    Mazzini, Cinzia
    CASE REPORTS IN OPHTHALMOLOGY, 2013, 4 (02): : 48 - 56
  • [27] An Analysis of the Factors Influencing the Residual Refractive Astigmatism After Cataract Surgery With Toric Intraocular Lenses
    Savini, Giacomo
    Naeser, Kristian
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (02) : 827 - 835
  • [28] Binocular function after bilateral implantation of monofocal and refractive multifocal intraocular lenses
    Arens, B
    Freudenthaler, N
    Quentin, CD
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (03): : 399 - 404
  • [29] Accuracy of toric intraocular lens implantation in cataract and refractive surgery
    Visser, Nienke
    Berendschot, Tos T. J. M.
    Bauer, Noel J. C.
    Jurich, Jessica
    Kersting, Oliver
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08): : 1394 - 1402
  • [30] Stereopsis after bilateral implantation of Toric intraocular lenses in high myopic cataract patients with astigmatism
    Fan, Wei
    Zhang, Guangbin
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (03): : 147 - 152