Linac reported steering error insensitive to 6 MV FFF transverse beam position deviations

被引:0
|
作者
McAloney, Jacob [1 ]
Biggs, Simon [2 ]
Sobolewski, Matthew [1 ,3 ]
机构
[1] Riverina Canc Care Ctr, Wagga Wagga, NSW, Australia
[2] Radiotherapy AI, Wagga Wagga, NSW, Australia
[3] Northern Beaches Canc Care, Frenchs Forest, Australia
关键词
Beam steering; FFF; Radiation field alignment; TECHNOLOGY;
D O I
10.1007/s13246-021-01067-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clinically significant beam position deviations were observed for a 6 MV FFF beam during patient specific QA on an Elekta linear accelerator. There was no significant reported transverse steering error from the machine ion chamber, and routine linac QA practices, including cardinal angle Winston-Lutz test, did not identify the deviations. Subsequent investigation using an electronic portal imaging device (EPID) revealed clinically significant beam position deviations for small steering errors. This prompted investigation into further impact and possible solutions. Testing set-points were established by adjusting transverse steering current to achieve introduced 2 T steering errors. Tests at each set-point included scanning water tank profiles and EPID images. A proposed method for adjusting the 2 T error sensitivity was tested via adjusting the 2 T loop parameter such that a reported error corresponds to specific beam position deviations. The testing set-points resulted in positional deviations of greater than 3 mm for reported errors of less than 1. A new method for improving 2 T error sensitivity was implemented. This work has shown that existing vendor protocol for establishing beam steering error for 6 MV FFF beams can lead to beam position deviations without machine interlocks or significant reported steering errors. Thus, an alternative method of establishing steering error sensitivity based on positional deviations is presented.
引用
收藏
页码:1377 / 1382
页数:6
相关论文
共 50 条
  • [31] Measurement and comparison of head scatter factor for 7 MV unflattened (FFF) and 6 MV flattened photon beam using indigenously designed columnar mini phantom
    Ashokkumar, Sigamani
    Nambiraj, Arunai
    Sinha, Sujit Nath
    Yadav, Girigesh
    Raman, Kothanda
    Bhushan, Manindra
    Thiyagarajan, Rajesh
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (03) : 170 - 180
  • [32] MCMEG: Simulations of both PDD and TPR for 6 MV LINAC photon beam using different MC codes
    Fonseca, T. C. F.
    Mendes, B. M.
    Lacerda, M. A. S.
    Silva, L. A. C.
    Paixao, L.
    Bastos, F. M.
    Ramirez, J. V.
    Junior, J. P. R.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 386 - 391
  • [33] Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
    Salama, E.
    Ali, A. S.
    Emad, N.
    Radi, A.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (02): : 70 - 76
  • [34] Response of TL dosimeters outside the field edge of a 6 MV Linac beam and its implication on patient dosimetry
    Nelson, V. K.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2079 - 2082
  • [35] PDD Analysis of a 6 MV FFF Beam From a Jawless Linear Accelerator with Double Stacked MLCs in the Presence of a Magnetic Field
    Omari, E.
    Lavvafi, H.
    Roeske, J.
    Sethi, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E241 - E241
  • [36] Inactivation of the Transverse Beam Steering Servo System and the Effect of Linac's Operating Dose Rates on X-Ray Beam's Center and Profile Characteristics
    Sham, E.
    Kassahun, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E309 - E310
  • [37] Monte Carlo Simulation-Based BEAMnrc Code of a 6 MV Photon Beam Produced by a Linear Accelerator (LINAC)
    Sapundani, R.
    Ekawati, R.
    Wibowo, K. M.
    ATOM INDONESIA, 2021, 47 (03) : 199 - 204
  • [38] Dose evaluation of Grid Therapy using a 6 MV flattening filter-free (FFF) photon beam: A Monte Carlo study
    Martinez-Rovira, Immaculada
    Puxeu-Vaque, Josep
    Prezado, Yolanda
    MEDICAL PHYSICS, 2017, 44 (10) : 5378 - 5383
  • [39] Monte Carlo Simulation of 6 MV Flattening Filter Free Photon Beam of TrueBeam STx LINAC at Songklanagarind Hospital
    Efendi, M. Arif
    Funsian, Amporn
    Chittrakarn, Thawat
    Bhongsuwan, Tripob
    SAINS MALAYSIANA, 2017, 46 (09): : 1407 - 1411
  • [40] Energy spectra in water for the 6 MV X-ray therapeutic beam generated by Clinac-2300 linac
    Konefal, Adam
    Bakoniak, Marzena
    Orlef, Andrzej
    Maniakowski, Zbigniew
    Szewczuk, Marek
    RADIATION MEASUREMENTS, 2015, 72 : 12 - 22