Electrochemical immunoassay for the detection of stress biomarkers

被引:13
|
作者
Abdulsattar, Jwan O. [1 ]
Greenway, Gillian M. [2 ]
Wadhawan, Jay D. [3 ]
机构
[1] Mustansiriyah Univ, Coll Sci, Dept Chem, Baghdad, Iraq
[2] Univ Hull, Dept Chem & Biochem, Cottingham Rd, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Univ Hull, Dept Chem Engn, Cottingham Rd, Kingston Upon Hull HU6 7RX, N Humberside, England
关键词
Biomedical engineering; Electrochemistry; Biosensors; Immunoassay; Stress biomarkers; Point of care; CORTISOL; GOLD; IMMUNOSENSORS; REDUCTION; ELECTRODE; HORMONES;
D O I
10.1016/j.heliyon.2020.e03558
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A rapid electrochemical immunoassay method was developed to detect and measure stress biomarkers (cortisol and cortisone) in two biological samples (Zebrafish whole-body and artificial saliva). This methodology utilizes an immunoassay approach taking advantage of the lock and key mechanism that is related to the antibody-antigen interaction depending on the reliable immobilization of the antibody labelled with ferrocene tags (Ab-Fc) on a modified tin-doped indium oxide (ITO) electrode using electrochemical instrumentation to build a POC platform. The limit of detection (LOD) obtained for this biosensor was 1.03 pg ml(-1) for cortisol and 0.68 pg ml(-1) for cortisone, respectively. The correlation coefficient was 0.9852 and 0.9841 for cortisol and cortisone, respectively with a linear concentration from (0-50 ng ml(-1)) which covers the standard levels of stress hormones in both selected biological samples. The incubation time was investigated and 30 min was found to be the optimum incubation time. This time would be acceptable for the POC system as total process time can be determined within 35 min.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] An automated and portable microfluidic chemiluminescence immunoassay for quantitative detection of biomarkers
    Hu, Binfeng
    Li, Juanjuan
    Mou, Lei
    Liu, Yong
    Deng, Jinqi
    Qian, Wei
    Sun, Jiashu
    Cha, Ruitao
    Jiang, Xingyu
    LAB ON A CHIP, 2017, 17 (13) : 2225 - 2234
  • [42] Membrane-Based Microwave-Mediated Electrochemical Immunoassay for the In Vitro, Highly Sensitive Detection of Osteoporosis-Related Biomarkers
    Kim, Hye Youn
    Sato, Shinobu
    Takenaka, Shigeori
    Lee, Min-Ho
    SENSORS, 2018, 18 (09)
  • [43] Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
    Chikkaveeraiah, Bhaskara V.
    Bhirde, Ashwinkumar A.
    Morgan, Nicole Y.
    Eden, Henry S.
    Chen, Xiaoyuan
    ACS NANO, 2012, 6 (08) : 6546 - 6561
  • [44] Application of electrochemical aptasensors in detection of cancer biomarkers
    Negandary, Masoud
    Moradi, Ali
    Heli, Hossein
    BIOMEDICAL RESEARCH AND THERAPY, 2019, 6 (07): : 3315 - 3324
  • [45] Nanofluidic electrochemical sensors for clinical biomarkers detection
    Hu, Yu-Lin
    Cui, Hai-Shan
    Yu, Chun-Mei
    Wu, Zeng-Qiang
    MICROCHEMICAL JOURNAL, 2023, 193
  • [46] Recent Advances in Electrochemical Aptasensors for Detection of Biomarkers
    Majdinasab, Marjan
    Marty, Jean Louis
    PHARMACEUTICALS, 2022, 15 (08)
  • [47] Electrochemical bioaffinity sensors for salivary biomarkers detection
    Campuzano, Susana
    Yanez-Sedeno, Paloma
    Pingarron, Jose M.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 86 : 14 - 24
  • [48] Electrochemical Sensing Detection of Biomarkers in Hematological Malignancies
    Gong, Miao
    Wang, Xiaoying
    Wang, Xiaoning
    PROGRESS IN CHEMISTRY, 2019, 31 (06) : 894 - 905
  • [49] Electrochemical Nanobiosensors for Detection of Breast Cancer Biomarkers
    Gajdosova, Veronika
    Lorencova, Lenka
    Kasak, Peter
    Tkac, Jan
    SENSORS, 2020, 20 (14) : 1 - 37
  • [50] ELECTROCHEMICAL ENZYME-IMMUNOASSAY FOR DETECTION OF TOXIC-SUBSTANCES
    ODALY, JP
    ZHAO, JG
    BROWN, PA
    HENKENS, RW
    ENZYME AND MICROBIAL TECHNOLOGY, 1992, 14 (04) : 299 - 302