摘要
A rapid electrochemical immunoassay method was developed to detect and measure stress biomarkers (cortisol and cortisone) in two biological samples (Zebrafish whole-body and artificial saliva). This methodology utilizes an immunoassay approach taking advantage of the lock and key mechanism that is related to the antibody-antigen interaction depending on the reliable immobilization of the antibody labelled with ferrocene tags (Ab-Fc) on a modified tin-doped indium oxide (ITO) electrode using electrochemical instrumentation to build a POC platform. The limit of detection (LOD) obtained for this biosensor was 1.03 pg ml(-1) for cortisol and 0.68 pg ml(-1) for cortisone, respectively. The correlation coefficient was 0.9852 and 0.9841 for cortisol and cortisone, respectively with a linear concentration from (0-50 ng ml(-1)) which covers the standard levels of stress hormones in both selected biological samples. The incubation time was investigated and 30 min was found to be the optimum incubation time. This time would be acceptable for the POC system as total process time can be determined within 35 min.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] ANYL 49-Electrochemical immunoassay based on quantum-dot labels for sensitive detection of protein biomarkers
    Wu, Hong
    Liu, Guodong
    Wang, Jun
    Lin, Yuehe
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [22] A multiplex immunoassay of serum biomarkers for the detection of uveal melanoma
    Jin Song
    Shannath L. Merbs
    Lori J. Sokoll
    Daniel W. Chan
    Zhen Zhang
    Clinical Proteomics, 2019, 16
  • [23] A multiplex immunoassay of serum biomarkers for the detection of uveal melanoma
    Song, Jin
    Merbs, Shannath L.
    Sokoll, Lori J.
    Chan, Daniel W.
    Zhang, Zhen
    CLINICAL PROTEOMICS, 2019, 16 (1)
  • [24] Simultaneous Electrochemical Multiplexed Immunoassay of Biomarkers Based on Multifunctionalized Graphene Nanotags
    Li, Qunfang
    Tang, Dianping
    Lou, Fangming
    Yang, Ximei
    Chen, Guonan
    CHEMELECTROCHEM, 2014, 1 (02): : 441 - 447
  • [25] Electrochemical Sensor for Multiplex Biomarkers Detection
    Wei, Fang
    Patel, Prabhudas
    Liao, Wei
    Chaudhry, Kishore
    Zhang, Lei
    Arellano-Garcia, Martha
    Hu, Shen
    Elashoff, David
    Zhou, Hui
    Shukla, Shilin
    Shah, Franky
    Ho, Chih-Ming
    Wong, David T.
    CLINICAL CANCER RESEARCH, 2009, 15 (13) : 4446 - 4452
  • [26] Electrochemical detection of cervical cancer biomarkers
    Anusha, Tummala
    Brahman, Pradeep Kumar
    Sesharamsingh, Bondili
    Lakshmi, Allu
    Bhavani, K. Sai
    CLINICA CHIMICA ACTA, 2025, 567
  • [28] Development of an electrochemical immunoassay for detection of gatifloxacin in swine urine
    Yi, Jian
    Meng, Meng
    Liu, Zhong-qiu
    Zhi, Jin-fang
    Zhang, Yuan-yang
    Xu, Jing
    Wang, Ya-bin
    Liu, Jin-ting
    Xi, Ri-mo
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2012, 13 (02): : 118 - 125
  • [29] Electrochemical Immunoassay Platform for Human Monkeypox Virus Detection
    Can, Goksu
    Perk, Benay
    Citil, Burak Ekrem
    Buyuksunetci, Yudum Tepeli
    Anik, Ulku
    ANALYTICAL CHEMISTRY, 2024, 96 (21) : 8342 - 8348
  • [30] Capillary electrophoretic enzyme immunoassay with electrochemical detection for thyroxine
    He, ZH
    Jin, WR
    ANALYTICAL BIOCHEMISTRY, 2003, 313 (01) : 34 - 40