Electrochemical immunoassay for the detection of stress biomarkers

被引:13
|
作者
Abdulsattar, Jwan O. [1 ]
Greenway, Gillian M. [2 ]
Wadhawan, Jay D. [3 ]
机构
[1] Mustansiriyah Univ, Coll Sci, Dept Chem, Baghdad, Iraq
[2] Univ Hull, Dept Chem & Biochem, Cottingham Rd, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Univ Hull, Dept Chem Engn, Cottingham Rd, Kingston Upon Hull HU6 7RX, N Humberside, England
关键词
Biomedical engineering; Electrochemistry; Biosensors; Immunoassay; Stress biomarkers; Point of care; CORTISOL; GOLD; IMMUNOSENSORS; REDUCTION; ELECTRODE; HORMONES;
D O I
10.1016/j.heliyon.2020.e03558
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A rapid electrochemical immunoassay method was developed to detect and measure stress biomarkers (cortisol and cortisone) in two biological samples (Zebrafish whole-body and artificial saliva). This methodology utilizes an immunoassay approach taking advantage of the lock and key mechanism that is related to the antibody-antigen interaction depending on the reliable immobilization of the antibody labelled with ferrocene tags (Ab-Fc) on a modified tin-doped indium oxide (ITO) electrode using electrochemical instrumentation to build a POC platform. The limit of detection (LOD) obtained for this biosensor was 1.03 pg ml(-1) for cortisol and 0.68 pg ml(-1) for cortisone, respectively. The correlation coefficient was 0.9852 and 0.9841 for cortisol and cortisone, respectively with a linear concentration from (0-50 ng ml(-1)) which covers the standard levels of stress hormones in both selected biological samples. The incubation time was investigated and 30 min was found to be the optimum incubation time. This time would be acceptable for the POC system as total process time can be determined within 35 min.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Simultaneous detection of five biomarkers of lung cancer by electrochemical immunoassay
    Shan, Jiao
    Ma, Zhanfang
    MICROCHIMICA ACTA, 2016, 183 (11) : 2889 - 2897
  • [2] Simultaneous detection of five biomarkers of lung cancer by electrochemical immunoassay
    Jiao Shan
    Zhanfang Ma
    Microchimica Acta, 2016, 183 : 2889 - 2897
  • [3] Detection of biomarkers for inflammatory diseases by an electrochemical immunoassay: The case of neopterin
    Centi, Sonia
    Tombelli, Sara
    Puntoni, Mariarita
    Domenici, Claudio
    Franek, Milan
    Palchetti, Ilaria
    TALANTA, 2015, 134 : 48 - 53
  • [4] IMMUNOASSAY WITH ELECTROCHEMICAL DETECTION
    HEINEMAN, WR
    HALSALL, HB
    WEHMEYER, KR
    DOYLE, MJ
    WRIGHT, DS
    METHODS OF BIOCHEMICAL ANALYSIS, 1987, 32 : 345 - 393
  • [5] A sensitive chemiluminescence based immunoassay for the detection of cortisol and cortisone as stress biomarkers
    Jwan O. Abdulsattar
    Gillian M. Greenway
    Journal of Analytical Science and Technology, 10
  • [6] A sensitive chemiluminescence based immunoassay for the detection of cortisol and cortisone as stress biomarkers
    Abdulsattar, Jwan O.
    Greenway, Gillian M.
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2019, 10 (01)
  • [7] CAPILLARY IMMUNOASSAY WITH ELECTROCHEMICAL DETECTION
    HALSALL, HB
    HEINEMAN, WR
    JENKINS, SH
    CLINICAL CHEMISTRY, 1988, 34 (09) : 1701 - 1702
  • [8] Application of electrochemical methods for the detection of abiotic stress biomarkers in plants
    Li, Zhilei
    Zhou, Jianping
    Dong, Tao
    Xu, Yan
    Shang, Yukui
    BIOSENSORS & BIOELECTRONICS, 2021, 182
  • [9] Voltammetric Immunoassay for the Detection of Protein Biomarkers
    Dou, Yue-Hua
    Haswell, Stephen J.
    Greenman, John
    Wadhawan, Jay
    ELECTROANALYSIS, 2012, 24 (02) : 264 - 272
  • [10] Electrochemical Lateral Flow Immunoassay with Built-In Electrodes for Ultrasensitive and Wireless Detection of Inflammatory Biomarkers
    Ying, Xudong
    Fu, Wenxuan
    Zhu, Lihang
    Sun, Tao
    Qi, Min
    Zhou, Lin
    Wang, Yafeng
    Wang, Jing
    Su, Bin
    Zhang, Jun
    ANALYTICAL CHEMISTRY, 2024, 96 (26) : 10630 - 10638