Novel Automated Suturing Technology for Minimally Invasive Mitral Chord Implantation: A Preclinical Evaluation Study

被引:2
|
作者
Werner, Paul [1 ]
Rath, Claus [1 ]
Gross, Christoph [1 ]
Ad, Niv [2 ]
Gosev, Igor [3 ]
Amirjamshidi, Hossein [3 ]
Poschner, Thomas [1 ]
Coti, Iuliana [1 ]
Russo, Marco [4 ]
Mach, Markus [1 ]
Kocher, Alfred [1 ]
Laufer, Guenther [1 ]
Sauer, Jude [3 ]
Andreas, Martin [1 ]
机构
[1] Med Univ Vienna, Dept Cardiac Surg, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Univ Maryland, Dept Surg, Sch Med, Baltimore, MD USA
[3] Med Univ Rochester, Dept Surg, Rochester, NY USA
[4] San Camillo Forlanini Hosp Rome, Rome, Italy
关键词
mitral regurgitation; mitral valve repair; chordal replacement; automated ePTFE suturing; new ePTFE titanium fastener; VALVE REPAIR; LEAFLET PROLAPSE; ARTIFICIAL CHORDAE; REPLACEMENT; RESECTION; REGURGITATION; DURABILITY; LENGTH;
D O I
10.1177/15569845221133381
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study evaluated the ergonomics and time requirements of using a novel automated suturing and titanium fastener deployment technology for chordal replacement in human heart specimens in open and minimally invasive cardiac surgery (MICS) simulators. Methods: Five cardiac surgeons used novel, manually poweredexpandedpolytetrafluoroethylene (ePTFE) suturing devices to automate suture placement between mitral leaflets and papillary muscles in explanted cadaver hearts, along with customized titanium fastener delivery devices to secure suture and trim suture tails. This mitral chordal replacement test was conducted using surgical models simulating open and MICS mitral repair access. The study was approved by the institutional ethical board. Results: After a brief introduction to this technique using plastic models, study surgeons performed 48 chordal replacements in human mitral valves, placing 18 in an open model and 30 in a right minithoracotomy model. The time range to complete a single chordal replacement was between 55 s and 8 min, with an overall mean duration of 3.6 +/- 1.5 min. No difference in duration of implantation was recorded for the MICS and open sternotomy simulators used. Good control of suture delivery was reported in 95.8% (n = 46) of leaflet aspect of the sutures and in 100% (N = 48) of papillary muscle sutures. Conclusions: Automated mitral chordal ePTFE suturing simulated through open and MICS access demonstrated quality handling and accurate placement of sutures in human heart specimens. A clinical trial using this technology is currently ongoing. This innovation may present an important advance facilitating enhanced minimally invasive mitral valve repair.
引用
收藏
页码:506 / 512
页数:7
相关论文
共 50 条
  • [41] Augmented Reality Surgical Navigation in Minimally Invasive Spine Surgery: A Preclinical Study
    Huang, Xin
    Liu, Xiaoguang
    Zhu, Bin
    Hou, Xiangyu
    Hai, Bao
    Yu, Dongfang
    Zheng, Wenhao
    Li, Ranyang
    Pan, Junjun
    Yao, Youjie
    Dai, Zailin
    Zeng, Haijun
    BIOENGINEERING-BASEL, 2023, 10 (09):
  • [42] A novel, minimally invasive technology for intrapericardial injections via direct visualization
    O'Hara, Ryan P.
    Opfermann, Justin D.
    Gonzalez, Bryan
    Clark, Bradley C.
    Berul, Charles I.
    Kumthekar, Rohan N.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024,
  • [43] EVALUATION OF A NOVEL, MINIMALLY INVASIVE TEST FOR FERTILITY HORMONES.
    Burke, E.
    Beqaj, S.
    Luo, R.
    FERTILITY AND STERILITY, 2018, 110 (04) : E42 - E42
  • [44] Minimally invasive technology for mitral valve surgery via left thoracotomy: Experience with forty cases
    Saunders, PC
    Grossi, EA
    Sharony, R
    Schwartz, CF
    Ribakove, GH
    Culliford, AT
    Delianides, J
    Baumann, FG
    Galloway, AC
    Colvin, SB
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (04): : 1026 - 1032
  • [45] A Novel Modified Minimally Invasive Trabeculectomy : A Preliminary Study
    Hong, Bennett Y.
    Zhou, You
    Mattingly, Jeffrey J.
    Bunag, Brittany A.
    Vizzeri, Gianmarco
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [46] Evaluation of Clinical Performance of Ponto Implantation Using a Minimally Invasive Surgical Technique-A Prospective Multicenter Study
    Teunissen, Emma M.
    Aukema, Tjerk W.
    Banga, Rupan
    Eeg-Olofsson, Mans
    Hol, Myrthe K. S.
    Hougaard, Dan D.
    Tysome, James R.
    Johansson, Martin L.
    Svensson, Sara
    Powell, Harry R. F.
    OTOLOGY & NEUROTOLOGY, 2024, 45 (09) : 1037 - 1044
  • [47] Workflow assessment as a preclinical development tool: Surgical process models of three techniques for minimally invasive cochlear implantation
    Mueller, Samuel
    Kahrs, Lueder A.
    Gaa, Johannes
    Tauscher, Sebastian
    Kluge, Marcel
    John, Samuel
    Rau, Thomas S.
    Lenarz, Thomas
    Ortmaier, Tobias
    Majdani, Omid
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (08) : 1389 - 1401
  • [48] Minimally Invasive Tube Surgery (MITS)-A Novel Method in Glaucoma Drainage Device Implantation
    Singh, Bharpoor
    Swampillai, Andrew J.
    Utukuri, Mrudula
    Normando, Eduardo M.
    Mazrouaa, Ahmed
    Al-Nahrawy, Ahmed
    Ahmed, Faisal
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (21)
  • [49] A successful minimally invasive mitral valve repair following delayed device embolization in a patient with Pascal device implantation
    Akansel, Serdar
    Suendermann, Simon H.
    Kofler, Markus
    Van Praet, Karel M.
    Kukucka, Marian
    Falk, Volkmar
    Kempfert, Joerg
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 28 (02): : 404 - 406
  • [50] A minimally invasive catheter-based ultrasound technology for therapeutic interventions in brain: initial preclinical studies
    Ghoshal, Goutam
    Gee, Lucy
    Heffter, Tamas
    Williams, Emery
    Bromfield, Corinne
    Rund, Laurie
    Ehrhardt, John M.
    Diederich, Chris J.
    Fischer, Gregory S.
    Pilitsis, Julie G.
    Burdette, E. Clif
    NEUROSURGICAL FOCUS, 2018, 44 (02)