Novel Automated Suturing Technology for Minimally Invasive Mitral Chord Implantation: A Preclinical Evaluation Study

被引:2
|
作者
Werner, Paul [1 ]
Rath, Claus [1 ]
Gross, Christoph [1 ]
Ad, Niv [2 ]
Gosev, Igor [3 ]
Amirjamshidi, Hossein [3 ]
Poschner, Thomas [1 ]
Coti, Iuliana [1 ]
Russo, Marco [4 ]
Mach, Markus [1 ]
Kocher, Alfred [1 ]
Laufer, Guenther [1 ]
Sauer, Jude [3 ]
Andreas, Martin [1 ]
机构
[1] Med Univ Vienna, Dept Cardiac Surg, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Univ Maryland, Dept Surg, Sch Med, Baltimore, MD USA
[3] Med Univ Rochester, Dept Surg, Rochester, NY USA
[4] San Camillo Forlanini Hosp Rome, Rome, Italy
关键词
mitral regurgitation; mitral valve repair; chordal replacement; automated ePTFE suturing; new ePTFE titanium fastener; VALVE REPAIR; LEAFLET PROLAPSE; ARTIFICIAL CHORDAE; REPLACEMENT; RESECTION; REGURGITATION; DURABILITY; LENGTH;
D O I
10.1177/15569845221133381
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study evaluated the ergonomics and time requirements of using a novel automated suturing and titanium fastener deployment technology for chordal replacement in human heart specimens in open and minimally invasive cardiac surgery (MICS) simulators. Methods: Five cardiac surgeons used novel, manually poweredexpandedpolytetrafluoroethylene (ePTFE) suturing devices to automate suture placement between mitral leaflets and papillary muscles in explanted cadaver hearts, along with customized titanium fastener delivery devices to secure suture and trim suture tails. This mitral chordal replacement test was conducted using surgical models simulating open and MICS mitral repair access. The study was approved by the institutional ethical board. Results: After a brief introduction to this technique using plastic models, study surgeons performed 48 chordal replacements in human mitral valves, placing 18 in an open model and 30 in a right minithoracotomy model. The time range to complete a single chordal replacement was between 55 s and 8 min, with an overall mean duration of 3.6 +/- 1.5 min. No difference in duration of implantation was recorded for the MICS and open sternotomy simulators used. Good control of suture delivery was reported in 95.8% (n = 46) of leaflet aspect of the sutures and in 100% (N = 48) of papillary muscle sutures. Conclusions: Automated mitral chordal ePTFE suturing simulated through open and MICS access demonstrated quality handling and accurate placement of sutures in human heart specimens. A clinical trial using this technology is currently ongoing. This innovation may present an important advance facilitating enhanced minimally invasive mitral valve repair.
引用
收藏
页码:506 / 512
页数:7
相关论文
共 50 条
  • [31] Minimally invasive mitral valve repair for degenerative etiology: a comparative study
    Mohamed Abdel Hafez Fouly
    Tarek K. Mousa
    The Cardiothoracic Surgeon, 29
  • [32] Minimally invasive mitral valve repair for degenerative etiology: a comparative study
    Fouly, Mohamed Abdel Hafez
    Mousa, Tarek K.
    CARDIOTHORACIC SURGEON, 2021, 29 (01):
  • [33] Novel Mitral Repair Device for the Treatment of Severe Mitral Regurgitation Preclinical Ovine Acute and Chronic Implantation Model
    Hill, Arthur C.
    Lesh, Michael D.
    Khairkhahan, Alexander
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2014, 9 (06) : 432 - 438
  • [34] Workflow assessment as a preclinical development toolSurgical process models of three techniques for minimally invasive cochlear implantation
    Samuel Müller
    Lüder A. Kahrs
    Johannes Gaa
    Sebastian Tauscher
    Marcel Kluge
    Samuel John
    Thomas S. Rau
    Thomas Lenarz
    Tobias Ortmaier
    Omid Majdani
    International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 1389 - 1401
  • [35] A novel model for minimally invasive left ventricular assist device implantation training
    Robinson, Davida
    Fitzsimmons, Michael
    Waters, Kenneth
    Mohiuddin, Farrukh
    Knight, Peter
    Sauer, Jude
    Johnson, Carl, Jr.
    Gosev, Igor
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2020, 29 (04) : 194 - 201
  • [36] Minimally invasive repair of congenital inguinal hernias in nine foals using an automated laparoscopic suturing device and barbed suture
    Maurer, Thimo
    McEntee, Tony M.
    O'Brien, Tom
    Coleridge, Matthew
    Brunisholz, Herve P.
    Petruccione, Ilaria
    Koch, Christoph
    EQUINE VETERINARY EDUCATION, 2024, 36 (06) : 296 - 306
  • [37] In vitro stability testing of a novel implantation system for the minimally invasive transforaminal approach
    Schneid, S
    Sabitzer, RJ
    Fuss, FK
    Grupp, TM
    Blömer, W
    ORTHOPADE, 2002, 31 (05): : 488 - +
  • [38] Asia's First Successful Minimally Invasive Transapical Transcatheter Mitral Valve-in-Valve Implantation
    Soon, Jia Lin
    Chua, Yeow Leng
    Chao, Victor T. T.
    Chiam, Paul T. L.
    Ewe, See Hooi
    Seetho, Ving Yuen
    Lee, Chung Yin
    Tan, Swee Yaw
    Koh, Tian Hai
    Sin, Kenny Y. K.
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2013, 42 (02) : 85 - 87
  • [39] Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws
    Keric, Naureen
    Doenitz, Christian
    Haj, Amer
    Rachwal-Czyzewicz, Izabela
    Renovanz, Mirjam
    Wesp, Dominik M. A.
    Boor, Stephan
    Conrad, Jens
    Brawanski, Alexander
    Giese, Alf
    Kantelhardt, Sven R.
    NEUROSURGICAL FOCUS, 2017, 42 (05)
  • [40] Minimally Invasive Left Ventricular Assist Device Implantation: A Comparative Study
    Mohite, Prashant N.
    Sabashnikov, Anton
    Raj, Binu
    Hards, Rachel
    Edwards, Gemma
    Garcia-Saez, Diana
    Zych, Bartlomiej
    Husain, Mubassher
    Jothidasan, Anand
    Fatullayev, Javid
    Zeriouh, Mohamed
    Weymann, Alexander
    Popov, Aron-Frederik
    De Robertis, Fabio
    Simon, Andre R.
    ARTIFICIAL ORGANS, 2018, 42 (12) : 1125 - 1131