A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head

被引:41
|
作者
Hijikata, Wataru [2 ]
Shinshi, Tadahiko [1 ]
Asama, Junichi [1 ]
Li, Lichuan [3 ]
Hoshi, Hideo [4 ]
Takatani, Setsuo [4 ]
Shimokohbe, Akira [1 ]
机构
[1] Tokyo Inst Technol, Precis & Intelligence Lab, Midori Ku, Yokohama, Kanagawa 2268503, Japan
[2] Interdisciplinary Grad Sch Sci & Engn, Yokohama, Kanagawa, Japan
[3] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
[4] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Tokyo, Japan
关键词
centrifugal blood pump; disposable pump head; magnetic bearing; magnetic coupling; heat generation;
D O I
10.1111/j.1525-1594.2008.00576.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A magnetically levitated centrifugal blood pump (MedTech Dispo) has been developed for use in a disposable extracorporeal system. The design of the pump is intended to eliminate mechanical contact with the impeller, to facilitate a simple disposable mechanism, and to reduce the blood-heating effects that are caused by motors and magnetic bearings. The bearing rotor attached to the impeller is suspended by a two degrees-of-freedom controlled radial magnetic bearing stator, which is situated outside the rotor. In the space inside the ringlike rotor, a magnetic coupling disk is placed to rotate the rotor and to ensure that the pump head is thermally isolated from the motor. In this system, the rotor can exhibit high passive stiffness due to the novel design of the closed magnetic circuits. The disposable pump head, which has a priming volume of 23 mL, consists of top and bottom housings, an impeller, and a rotor with a diameter of 50 mm. The pump can provide a head pressure of more than 300 mm Hg against a flow of 5 L/min. The normalized index of hemolysis of the MedTech Dispo is 0.0025 +/- 0.0005 g/100 L at 5 L/min against 250 mm Hg. This is one-seventh of the equivalent figure for a Bio Pump BPX-80 (Medtronic, Inc., Minneapolis, MN, USA), which has a value of 0.0170 +/- 0.0096 g/100 L. These results show that the MedTech Dispo offers high pumping performance and low blood trauma.
引用
收藏
页码:531 / 540
页数:10
相关论文
共 50 条
  • [31] Magnetically suspended centrifugal blood pump with a self bearing motor
    Masuzawa, T
    Onuma, H
    Kim, SJ
    Okada, Y
    [J]. ASAIO JOURNAL, 2002, 48 (04) : 437 - 442
  • [32] Magnetically suspended centrifugal blood pump with a radial magnetic driver
    Hoshi, H
    Katakoa, K
    Ohuchi, K
    Asama, J
    Shinshi, T
    Shimokohbe, A
    Takatani, S
    [J]. ASAIO JOURNAL, 2005, 51 (01) : 60 - 64
  • [33] Trends in integration for magnetically levitated pump systems
    Nussbaumer, T.
    Raggl, K.
    Boesch, P.
    Kolar, J. W.
    [J]. 2007 POWER CONVERSION CONFERENCE - NAGOYA, VOLS 1-3, 2007, : 1507 - +
  • [34] Magnetically Levitated Cardiac Pump at 2 Years
    Moayedi, Yasbanoo
    Posada, Juan G. Duero
    Rao, Vivek
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2018, 379 (09): : 896 - 897
  • [35] The DuraHeart VAD, a magnetically levitated centrifugal pump - The University of Vienna bridge-to-transplant experience
    Nishinaka, Tomohiro
    Schima, Heinrich
    Roethy, Wilfried
    Rajek, Angela
    Nojiri, Chisato
    Wolner, Ernest
    Wieselthaler, Georg M.
    [J]. CIRCULATION JOURNAL, 2006, 70 (11) : 1421 - 1425
  • [36] The Terumo DuraHeart magnetically levitated centrifugal pump:: First clinical experience for bridge to transplantation in Vienna
    Röthy, W
    Zrunek, R
    Nishinaka, T
    Rajek, A
    Schima, H
    Wolner, E
    Wieselthaler, G
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 507 - 507
  • [37] Evaluation of Erythrocyte Flow at a Bearing Gap in a Hydrodynamically Levitated Centrifugal Blood Pump
    Murashige, Tomotaka
    Kosaka, Ryo
    Sakota, Daisuke
    Nishida, Masahiro
    Kawaguchi, Yasuo
    Yamane, Takashi
    Maruyama, Osamu
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 270 - 273
  • [38] Fluid Dynamic Design for Low Hemolysis in a Hydrodynamically Levitated Centrifugal Blood Pump
    Murashige, Tomotaka
    Kosaka, Ryo
    Nishida, Masahiro
    Maruyama, Osamu
    Yamane, Takashi
    Kuwana, Katsuyuki
    Kawaguchi, Yasuo
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2732 - 2735
  • [39] Visualization of main and leakage flow in magnetically suspended centrifugal blood pump
    Masaaki Horie
    Keiichi Yamamura
    [J]. Journal of Visualization, 2012, 15 : 353 - 361
  • [40] DEVELOPMENT OF MAGNETICALLY SUSPENDED VANELESS CENTRIFUGAL BLOOD PUMP FOR CARDIOPULMONARY BYPASS
    Lee, Y.
    Chang, J. K.
    Lee, S. H.
    Jang, J. U.
    Lee, K. B.
    Lee, H. W.
    Sun, K.
    Kim, H. M.
    Kim, J.
    Yoo, J. Y.
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2003, 3 (02) : 187 - 196