Technical Note: Nuclear imaging with an x-ray flat panel detector: A proof-of-concept study

被引:2
|
作者
Dietze, Martijn M. A. [1 ,2 ,3 ]
Koppert, Wilco J. C. [1 ,2 ]
van Rooij, Rob [1 ,2 ]
de Jong, Hugo W. A. M. [1 ,2 ]
机构
[1] Univ Utrecht, Radiol & Nucl Med, POB 85500, Utrecht 3508 GA, Netherlands
[2] Univ Med Ctr Utrecht, POB 85500, Utrecht 3508 GA, Netherlands
[3] Univ Utrecht, Image Sci Inst, POB 85500, Utrecht 3508 GA, Netherlands
基金
欧洲研究理事会;
关键词
CBCT; collimator; flat panel; Gamma camera; SPECT; GAMMA-CAMERA ARCHITECTURE; OPTIMIZATION;
D O I
10.1002/mp.14191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Interventional procedures involving radionuclides (e.g., radioembolization) would benefit from single-photon emission computed tomography (SPECT) performed in the intervention room because the activity distribution could be immediately visualized. We believe it might be possible to perform SPECT with the C-arm cone beam computed tomography (CBCT) scanner present in the intervention room by equipping the x-ray flat panel detector with a collimator. The purpose of this study is to demonstrate the approach and to investigate the achievable SPECT reconstruction quality. Methods A proof-of-concept experiment was performed to evaluate the possibility of nuclear imaging with an x-ray flat panel detector. The experiment was digitally replicated to study the accuracy of the simulations. Three flat panel configurations (with standard hardware and reconstruction methodology, with sophisticated reconstruction methodology, and with expected future hardware) and a conventional gamma camera were evaluated. The Jaszczak and the NEMA IQ phantom (filled with Tc-99m) were simulated and assessed on resolution and contrast-to-noise ratio (CNR). Results The proof-of-concept experiment demonstrated that nuclear images could be obtained from the flat panel detector. The simulation of the same configuration demonstrated that simulations could accurately predict the flat panel detector response. The CNR of the 37 mm sphere in the NEMA IQ phantom was 22.8 +/- 1.2 for the gamma camera reconstructions, while it was 11.3 +/- 0.7 for the standard flat panel detector. With sophisticated reconstruction methodology, the CNR improved to 13.5 +/- 1.4. The CNR can be expected to advance to 18.1 +/- 1.3 for future flat panel detectors. Conclusions The x-ray flat panel detector of a CBCT scanner might be used to perform nuclear imaging. The SPECT reconstruction quality will be lower than that achieved by a conventional gamma camera. The flat panel detector approach could, however, be useful in providing a cost-effective alternative to the purchase of a mobile SPECT scanner for enabling interventional scanning.
引用
收藏
页码:3363 / 3368
页数:6
相关论文
共 50 条
  • [41] Single-shot dual-energy x-ray imaging with a flat-panel sandwich detector for preclinical imaging
    Han, Jong Chul
    Kim, Ho Kyung
    Kim, Dong Woon
    Yun, Seungman
    Youn, Hanbean
    Kam, Soohwa
    Tanguay, Jesse
    Cunningham, Ian A.
    CURRENT APPLIED PHYSICS, 2014, 14 (12) : 1734 - 1742
  • [42] The Dexela 2923 CMOS X-ray detector: A flat panel detector based on CMOS active pixel sensors for medical imaging applications
    Konstantinidis, Anastasios C.
    Szafraniec, Magdalena B.
    Speller, Robert D.
    Olivo, Alessandro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 689 : 12 - 21
  • [43] A flat-panel X-ray imaging module for medical imaging and nondestructive testing
    Cho, Hyosung
    Choi, Sungil
    Lee, Bongsoo
    Kim, Sin
    ADVANCED NONDESTRUCTIVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 1004 - 1007
  • [44] Developing Cold Cathode Flat Panel X-Ray Source Module for Portal X-Ray Imaging System
    Wei, Haonan
    Liu, Qi
    Ou, Zhuoran
    Kang, Song
    Zhang, Guofu
    Zhang, Zhipeng
    Deng, Shaozhi
    Xu, Ningsheng
    Chen, Jun
    2024 37TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE, IVNC 2024, 2024,
  • [45] Sheet-beam geometry for in vivo fluorescent x-ray computed tomography: proof-of-concept experiment in molecular imaging
    Huo, Qingkai
    Yuasa, Tetsuya
    Akatsuka, Takao
    Takeda, Tohoru
    Wu, Jin
    Thet-Thet-Lwin
    Hyodo, Kazuyuki
    Dilmanian, F. Avraham
    OPTICS LETTERS, 2008, 33 (21) : 2494 - 2496
  • [46] Study on Medical X-ray Coherent Scatter Imaging and Processing Based Digital Flat Detector
    Liu, Jingxin
    Liu, Taihui
    Lv, Yan
    Hu, Boqi
    Li, Bo
    Zhao, Jinshan
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 589 - 592
  • [47] X-ray microtomography system for small and light samples using a flat panel detector
    Vilar, A. B.
    dos Santos, T. M. P.
    Machado, A. S.
    Oliveira, D. F.
    Azeredo, S. R.
    Lopes, R. T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (10):
  • [48] LOW SCATTER, HIGH KILOVOLT, A-SI FLAT PANEL X-RAY DETECTOR
    Smith, Peter D.
    Claytor, Thomas N.
    Berry, Phillip C.
    Hills, Charles R.
    Keating, Scott C.
    Phillips, David H.
    Setoodeh, Shariar
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 28A AND 28B, 2009, 1096 : 1672 - +
  • [49] Characterization of a flat-panel amorphous silicon detector for X-ray computed tomography
    Lee, H.-R.
    Ellingson, W.
    Journal of X-Ray Science and Technology, 2001, 9 (01) : 43 - 53
  • [50] Use of an Irrigating External Ventricular Drain in an Infant: Proof-Of-Concept Technical Note
    Hamilton, Kimberly
    Brandmeir, Nick
    Adelson, P. David
    WORLD NEUROSURGERY, 2024, 189 : 174 - 180