Technical Note: Nuclear imaging with an x-ray flat panel detector: A proof-of-concept study

被引:2
|
作者
Dietze, Martijn M. A. [1 ,2 ,3 ]
Koppert, Wilco J. C. [1 ,2 ]
van Rooij, Rob [1 ,2 ]
de Jong, Hugo W. A. M. [1 ,2 ]
机构
[1] Univ Utrecht, Radiol & Nucl Med, POB 85500, Utrecht 3508 GA, Netherlands
[2] Univ Med Ctr Utrecht, POB 85500, Utrecht 3508 GA, Netherlands
[3] Univ Utrecht, Image Sci Inst, POB 85500, Utrecht 3508 GA, Netherlands
基金
欧洲研究理事会;
关键词
CBCT; collimator; flat panel; Gamma camera; SPECT; GAMMA-CAMERA ARCHITECTURE; OPTIMIZATION;
D O I
10.1002/mp.14191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Interventional procedures involving radionuclides (e.g., radioembolization) would benefit from single-photon emission computed tomography (SPECT) performed in the intervention room because the activity distribution could be immediately visualized. We believe it might be possible to perform SPECT with the C-arm cone beam computed tomography (CBCT) scanner present in the intervention room by equipping the x-ray flat panel detector with a collimator. The purpose of this study is to demonstrate the approach and to investigate the achievable SPECT reconstruction quality. Methods A proof-of-concept experiment was performed to evaluate the possibility of nuclear imaging with an x-ray flat panel detector. The experiment was digitally replicated to study the accuracy of the simulations. Three flat panel configurations (with standard hardware and reconstruction methodology, with sophisticated reconstruction methodology, and with expected future hardware) and a conventional gamma camera were evaluated. The Jaszczak and the NEMA IQ phantom (filled with Tc-99m) were simulated and assessed on resolution and contrast-to-noise ratio (CNR). Results The proof-of-concept experiment demonstrated that nuclear images could be obtained from the flat panel detector. The simulation of the same configuration demonstrated that simulations could accurately predict the flat panel detector response. The CNR of the 37 mm sphere in the NEMA IQ phantom was 22.8 +/- 1.2 for the gamma camera reconstructions, while it was 11.3 +/- 0.7 for the standard flat panel detector. With sophisticated reconstruction methodology, the CNR improved to 13.5 +/- 1.4. The CNR can be expected to advance to 18.1 +/- 1.3 for future flat panel detectors. Conclusions The x-ray flat panel detector of a CBCT scanner might be used to perform nuclear imaging. The SPECT reconstruction quality will be lower than that achieved by a conventional gamma camera. The flat panel detector approach could, however, be useful in providing a cost-effective alternative to the purchase of a mobile SPECT scanner for enabling interventional scanning.
引用
收藏
页码:3363 / 3368
页数:6
相关论文
共 50 条
  • [1] Concept of a Movable Flat Panel Detector for X-ray Imaging during Surgical Interventions
    Engel, S.
    Kaeseberg, M.
    Stopp, F.
    Fehlhaber, F.
    Keeve, E.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 1113 - 1113
  • [2] Technical Note: A feasibility study of using the flat panel detector on linac for the kV x-ray generator test
    Cai, Bin
    Dolly, Steven
    Kamal, Gregory
    Yaddanapudi, Sridhar
    Sun, Baozhou
    Goddu, S. Murty
    Mutic, Sasa
    Li, Hua
    MEDICAL PHYSICS, 2018, 45 (07) : 3305 - 3314
  • [3] Mathematical model based on X-ray imaging system of flat panel detector
    Liang, Li-Hong
    Guo, Wen-Ming
    Lu, Hong-Nian
    Guangxue Jishu/Optical Technique, 2005, 31 (04): : 630 - 632
  • [4] Performance characteristics of an amorphous silicon flat panel X-ray imaging detector
    Granfors, PR
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 480 - 490
  • [5] Fluoroscopic performance of an amorphous silicon flat panel x-ray imaging detector
    Granfors, PR
    RADIOLOGY, 1998, 209P : 161 - 161
  • [6] An X-ray tomograph based on a flat panel detector
    Constantin, F.
    Pavel, C.
    Bugoi, R.
    Toderas, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 685 - 689
  • [7] Fluorescent X-Ray Computed Tomography towards Molecular Imaging: Proof-of-Concept Experiments
    Yuasa, Tetsuya
    Huo, Qingkai
    Akatsuka, Takao
    Takeda, Tohoru
    Hyodo, Kazuyuki
    Dilmanian, F. Avraham
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 874 - 877
  • [8] Integration of flat panel X-ray detector for high resolution diagnostic medical imaging
    Kim, Min-woo
    Yun, Min-seok
    Kim, Yoon-suk
    Oh, Kyung-min
    Shin, Jung-wook
    Nam, Kyung-tae
    Nam, Sang-hee
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S40 - S42
  • [9] Point spread function modeling method for X-ray flat panel detector imaging
    Zhang, Hua
    Shi, Yikai
    Huang, Kuidong
    Yu, Qingchao
    6TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2012, 8417
  • [10] Performance of an amorphous silicon flat panel X-ray imaging detector for general radiography
    Granfors, PR
    Aufrichtig, R
    RADIOLOGY, 1999, 213P : 234 - 234