Results of AFX Unibody Stent-Graft Implantation in Patients With TASC D Aortoiliac Lesions and Coexistent Abdominal Aortic Aneurysms

被引:7
|
作者
Sirignano, Pasqualino [1 ]
Mansour, Wassim [1 ]
Capoccia, Laura [1 ]
Pranteda, Chiara [1 ]
Montelione, Nunzio [1 ,2 ]
Speziale, Francesco [1 ]
机构
[1] Sapienza Univ Rome, Policlin Umberto I, Dept Surg P Stefanini, Vasc & Endovasc Surg Unit, Rome, Italy
[2] Univ Campus Biomed, Div Vasc Surg, Rome, Italy
关键词
abdominal aortic aneurysm; aortoiliac occlusive disease; common iliac artery; external iliac artery; occlusion; stenosis; TASC D lesion; unibody stent-graft; COVERED ENDOVASCULAR RECONSTRUCTION; OCCLUSIVE DISEASE; BYPASS; BIFURCATION; EXPERIENCE; OUTCOMES;
D O I
10.1177/1526602817730840
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To describe results of AFX unibody stent-graft treatment for TransAtlantic Inter-Society Consensus (TASC) D aortoiliac occlusive disease (AIOD) with coexistent abdominal aortic aneurysm (AAA). Methods: A retrospective analysis was conducted of 21 consecutive patients (mean age 73.6 +/- 6.4 years; 17 men) with TASC D AIOD plus AAA (diameter >3.5 cm) treated electively using the AFX stent-graft. Common iliac artery (CIA) and external iliac artery (EIA) stenosis or occlusion was reported. Outcome measures were technical and clinical success, improvement in ankle-brachial index (ABI), and improvement in Rutherford category. Immediate and midterm patency, AAA exclusion, major adverse events (MAE), and mortality were also evaluated. Results: After AFX deployment (100% technical success), 18 EIAs required adjunctive stenting (none required in the CIA). One patient required a reintervention for closure device failure. At 30-day follow-up, no death or MAE was recorded. Improvement in ABI was registered in all patients (mean 0.91 +/- 0.11), with 100% primary patency. At a mean follow-up of 25.2 +/- 11.1 months, primary patency was maintained in all cases. No death or amputation occurred; 2 patients had a myocardial infarction. Improvement in ABI was maintained (0.88 +/- 0.13) as well as Rutherford category. Conclusion: This study examined the use of the AFX unibody stent-graft for the treatment of TASC D AIOD with concomitant AAA. The AFX stent-graft appears to be a safe and effective solution for these complex lesions, with low morbidity and mortality.
引用
收藏
页码:846 / 851
页数:6
相关论文
共 50 条
  • [31] Early experience with the talent™ stent-graft system for endoluminal repair of abdominal aortic aneurysms
    Criado, FJ
    Wilson, EP
    Wellons, E
    Abul-Khoudoud, O
    Gnanasekeram, H
    TEXAS HEART INSTITUTE JOURNAL, 2000, 27 (02) : 128 - 135
  • [32] Endovascular repair of abdominal aortic aneurysms: Stent-graft fixation across the visceral arteries
    Burks, JA
    Faries, PL
    Gravereaux, EC
    Hollier, LH
    Marin, ML
    JOURNAL OF VASCULAR SURGERY, 2002, 35 (01) : 109 - 113
  • [33] Change in aneurysm diameter after stent-graft repair of ruptured abdominal aortic aneurysms
    Arya, N
    Lee, B
    Loan, W
    Johnston, LC
    Boyd, CS
    Hannon, RJ
    Soong, CV
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (03) : 319 - 322
  • [34] Six-year experience with talent stent-graft repair of abdominal aortic aneurysms
    Espinosa, G
    Ribeiro, M
    Riguetti, C
    Caramalho, MF
    Mendes, WDS
    Santos, SR
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (01) : 35 - 45
  • [35] Hemodynamic stability of patients undergoing endovascular stent-graft procedures versus open aortic repair for abdominal aortic aneurysms
    Kahn, RA
    Moskowitz, DM
    McConville, JC
    Manspeizer, HE
    Reich, DL
    Marin, M
    Hollier, L
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S):
  • [36] Results Following Stent-Graft Coverage of the Hypogastric Artery in the Management of Aortoiliac Aneurysms in Endovascular Aneurysm Repair
    Armatowicz, Paul
    Szostek, Malgorzata
    Jakuczun, Wawrzyniec
    Skorski, Maciej
    POLISH JOURNAL OF SURGERY, 2023, 95 (05) : 78 - 80
  • [37] Embolization of perigraft leaks following abdominal aortic stent-graft: Midterm results
    Golzarian, J
    Said, KA
    Dussaussois, LM
    Abada, HT
    Dereume, J
    Struyven, JL
    RADIOLOGY, 1999, 213P : 134 - 134
  • [38] Hemodynamic impact of abdominal aortic aneurysm stent-graft implantation-induced stenosis
    Nicolas Aristokleous
    Nikolaos G. Kontopodis
    Konstantinos Tzirakis
    Christos V. Ioannou
    Yannis Papaharilaou
    Medical & Biological Engineering & Computing, 2016, 54 : 1523 - 1532
  • [39] Treatment Results of Endovascular Aneurysm Repair Using the Parallel Stent-Graft Double D Technique for Distal Saccular Abdominal Aortic Aneurysms and Common Iliac Aneurysms
    Mizoguchi, Takahiro
    Morikage, Noriyasu
    Takeuchi, Yuriko
    Nagase, Takashi
    Samura, Makoto
    Harada, Takasuke
    Suehiro, Kotaro
    Hamano, Kimikazu
    ANNALS OF VASCULAR SURGERY, 2021, 71 : 392 - 401
  • [40] Hemodynamic impact of abdominal aortic aneurysm stent-graft implantation-induced stenosis
    Aristokleous, Nicolas
    Kontopodis, Nikolaos G.
    Tzirakis, Konstantinos
    Ioannou, Christos V.
    Papaharilaou, Yannis
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (10) : 1523 - 1532