Purpose: To describe results of AFX unibody stent-graft treatment for TransAtlantic Inter-Society Consensus (TASC) D aortoiliac occlusive disease (AIOD) with coexistent abdominal aortic aneurysm (AAA). Methods: A retrospective analysis was conducted of 21 consecutive patients (mean age 73.6 +/- 6.4 years; 17 men) with TASC D AIOD plus AAA (diameter >3.5 cm) treated electively using the AFX stent-graft. Common iliac artery (CIA) and external iliac artery (EIA) stenosis or occlusion was reported. Outcome measures were technical and clinical success, improvement in ankle-brachial index (ABI), and improvement in Rutherford category. Immediate and midterm patency, AAA exclusion, major adverse events (MAE), and mortality were also evaluated. Results: After AFX deployment (100% technical success), 18 EIAs required adjunctive stenting (none required in the CIA). One patient required a reintervention for closure device failure. At 30-day follow-up, no death or MAE was recorded. Improvement in ABI was registered in all patients (mean 0.91 +/- 0.11), with 100% primary patency. At a mean follow-up of 25.2 +/- 11.1 months, primary patency was maintained in all cases. No death or amputation occurred; 2 patients had a myocardial infarction. Improvement in ABI was maintained (0.88 +/- 0.13) as well as Rutherford category. Conclusion: This study examined the use of the AFX unibody stent-graft for the treatment of TASC D AIOD with concomitant AAA. The AFX stent-graft appears to be a safe and effective solution for these complex lesions, with low morbidity and mortality.
引用
收藏
页码:846 / 851
页数:6
相关论文
共 50 条
  • [21] Endoluminal Stent-Graft Placement for Repair of Abdominal Aortic Aneurysms in the Community Setting
    Traul, David
    Street, David
    Faught, William
    Eaton, Mark
    Castillo, Juan
    Brawner, John
    Varner, Lena
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (06) : 688 - 694
  • [22] HEMODYNAMICS OF ABDOMINAL AORTIC ANEURYSM AND ITS CLINICAL RELEVANCE IN PATIENTS WITH INFRARENAL STENT-GRAFT IMPLANTATION
    Lu, Y. -H
    Liu, G. -T
    Lin, S. -H
    Chen, C. -Y
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [23] Results of Endovascular Abdominal Aortic Aneurysm Repair with the Zenith stent-graft
    Bos, W. T. G. J.
    Tielliu, I. F. J.
    Zeebregts, C. J.
    Prins, T. R.
    van den Dungen, J. J. A. M.
    Verhoeven, E. L. G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 36 (06) : 653 - 660
  • [24] Treatment of abdominal aortic aneurysm with AorfixTM stent-graft - early results
    Makaloski, V.
    Wyss, T.
    Meier-Fiorese, G.
    Kissling, P.
    Do, D.
    Schmidli, J.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 18 - 18
  • [25] DOSE-AREA PRODUCT TO PATIENTS DURING STENT-GRAFT TREATMENT OF THORACIC AND ABDOMINAL AORTIC ANEURYSMS
    Blaszak, M. A.
    Majewska, N.
    Juszkat, R.
    Majewski, W.
    HEALTH PHYSICS, 2009, 97 (03): : 206 - 211
  • [26] Endovascular Repair of Abdominal Aortic Aneurysms With Reverse Taper Neck Anatomy Using the Endurant Stent-Graft: Analysis of Stent-Graft Oversizing
    Mwipatayi, Bibombe P.
    Picardo, Alarick
    Wong, Jackie
    Thomas, Shannon D.
    Vijayan, Vikram
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 514 - 522
  • [27] Abdominal Stent-Graft Treatment of Ascending Aortic Pseudoaneurysm Following Transcatheter Aortic Valve Implantation
    Kuhelj, Dimitrij
    Langel, Crt
    Bunc, Matjaz
    Ksela, Jus
    MEDICINA-LITHUANIA, 2023, 59 (01):
  • [28] The utility of Prostar XL percutaneous vascular closure device after stent-graft implantation for infrarenal abdominal aortic aneurysms
    Ilzecki, Marek
    Majewski, Marek
    Terlecki, Piotr
    Przywara, Stanislaw
    Rogala, Wojciech
    Rybak, Janusz
    Zubilewicz, Tomasz
    ACTA ANGIOLOGICA, 2018, 24 (03): : 74 - 79
  • [29] Long-term results after endovascular repair of abdominal aortic aneurysms with the stentor and vanguard stent-graft
    Engellau, L
    Albrechtsson, U
    Norgren, L
    Larsson, EM
    ACTA RADIOLOGICA, 2004, 45 (03) : 275 - 283
  • [30] Stent-graft placement in atherosclerotic descending thoracic aortic aneurysms: Midterm results
    Czerny, M
    Cejna, M
    Hutschala, D
    Fleck, T
    Holzenbein, T
    Schoder, M
    Lammer, J
    Zimpfer, D
    Ehrlich, M
    Wolner, E
    Grabenwoger, M
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (01) : 26 - 32