New endoprosthesis suspension method with polypropylene monofilament knitted mesh after resection of bone tumors in proximal humerus

被引:15
|
作者
Fujibuchi, Taketsugu [1 ]
Matsumoto, Seiichi [1 ]
Shimoji, Takashi [1 ]
Ae, Keisuke [1 ]
Tanizawa, Taisuke [1 ]
Gokita, Tabu [1 ]
Hayakawa, Keiko [1 ]
机构
[1] Japanese Fdn Canc Res, Canc Inst Hosp, Dept Orthopaed Oncol, Koto Ku, Tokyo, Japan
关键词
Bone tumor; shoulder joint; endoprosthesis; artificial mesh; PROSTHESIS COMPOSITE RECONSTRUCTION; WIDE RESECTION; EXTREMITY TUMORS; REPLACEMENT; ALLOGRAFT; SHOULDER; ARTHROPLASTY; EXCISION; PART;
D O I
10.1016/j.jse.2014.10.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Endoprosthetic reconstruction of the proximal humerus is one of the standard procedures after resection of tumors of the proximal humerus and has been considered a reliable method to reconstruct the proximal humerus in recent reports. However, instability of the shoulder joint caused by loss of the rotator cuff and deltoid muscle function is often observed after such an endoprosthetic reconstruction. Methods: We performed the endoprosthesis suspension method with polypropylene monofilament knitted mesh. This suspension method, by which the endoprosthesis is suspended from the bone structure, was used after resection of tumors in 9 patients. We assessed postoperative stability of the shoulder joint by comparing these patients with 12 patients who underwent the conventional surgical technique, by which the mesh-wrapped endoprosthesis is attached only to soft tissue. Results: In radiographic and physical evaluation, 4 of the 12 patients in the soft tissue reconstruction group showed shoulder joint instability. No patient in the suspension method group showed subluxation of the humeral prosthesis. The mean shoulder flexion was 35 degrees and 65 degrees and the mean shoulder abduction was 40 degrees and 40 degrees for the soft tissue reconstruction group and the suspension method group, respectively. Discussion: Shoulder joint subluxation sometimes occurs because of elongation of the attached soft tissue in the conventional reconstruction with mesh, whereas no shoulder joint subluxation occurs after endoprosthetic reconstruction in the suspension method because the bone structure has no leeway for elongation. Excellent stability of our new method enables exercise of the surgical shoulder at an early stage, leading to improved range of shoulder joint motion.
引用
收藏
页码:882 / 888
页数:7
相关论文
共 37 条
  • [21] Are Vascularized Fibula Autografts a Long-lasting Reconstruction After Intercalary Resection of the Humerus for Primary Bone Tumors?
    Campanacci, Domenico Andrea
    Scanferla, Roberto
    Innocenti, Matteo
    Muratori, Francesco
    Puccini, Serena
    Scoccianti, Guido
    Beltrami, Giovanni
    Capanna, Rodolfo
    Innocenti, Marco
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2023, 481 (11) : 2185 - 2197
  • [22] Risk factors for prosthetic failure after total humerus resection due to primary or secondary malignant bone tumors and reconstruction
    Schmidt-Braekling, T.
    Andreou, D.
    Gosheger, G.
    Broeking, J. N.
    Wilhelmy, J.
    Henrichs, M-P.
    Nottrott, M.
    Hardes, J.
    Streitbuerger, A.
    [J]. ONCOLOGY RESEARCH AND TREATMENT, 2018, 41 : 170 - 170
  • [23] The bioexpandable prosthesis: A new perspective after resection of malignant bone tumors in children
    Baumgart, R
    Hinterwimmer, S
    Krammer, M
    Muensterer, O
    Mutschler, W
    [J]. JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2005, 27 (08) : 452 - 455
  • [24] Reconstruction and limb salvage after resection for malignant bone tumour of the proximal humerus - A sling procedure using a free vascularised fibular graft
    Wada, T
    Usui, M
    Isu, K
    Yamawakii, S
    Ishii, S
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05): : 808 - 813
  • [25] CORR Insights®: Are Vascularized Fibula Autografts a Long-lasting Reconstruction After Intercalary Resection of the Humerus for Primary Bone Tumors?
    Dodds, Seth D.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2023, 481 (11) : 2198 - 2199
  • [26] Capsular replacement with synthetic mesh - Effectiveness in preventing postoperative dislocation after wide resection of proximal femoral tumors and prosthetic reconstruction
    Masterson, EL
    Ferracini, R
    Griffin, AM
    Wunder, JS
    Bell, RS
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (08): : 860 - 866
  • [27] The role of mesh technology with tumor prosthesis reconstruction to reconstruct the extensor mechanism of knee joint after resection of proximal tibial tumors
    Liu, Bin
    Tan, Jia Chang
    Wang, Hui Lin
    Wu, Zhenjie
    Yuan, Zhen Chao
    Wei, Chang Yuan
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [28] The role of mesh technology with tumor prosthesis reconstruction to reconstruct the extensor mechanism of knee joint after resection of proximal tibial tumors
    Bin Liu
    Jia Chang Tan
    Hui Lin Wang
    Zhenjie Wu
    Zhen Chao Yuan
    Chang Yuan Wei
    [J]. Journal of Orthopaedic Surgery and Research, 14
  • [29] What Is the Survival of the Telescope Allograft Technique to Augment a Short Proximal Femur Segment in Children After Resection and Distal Femur Endoprosthesis Reconstruction for a Bone Sarcoma?
    Hindiskere, Suraj
    Staals, Eric
    Donati, Davide Maria
    Manfrini, Marco
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (08) : 1780 - 1790
  • [30] BONE RECONSTRUCTION AFTER GIANT-CELL TUMOR RESECTION AT THE PROXIMAL END OF THE HUMERUS WITH VASCULARIZED ILIAC CREST GRAFT - A REPORT OF 3 CASES
    LEUNG, PC
    HUNG, LK
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (247) : 101 - 105