Regional ventilation by electrical impedance tomography - A comparison with ventilation scintigraphy in pigs

被引:126
|
作者
Hinz, J
Neumann, P
Dudykevych, T
Andersson, LG
Wrigge, H
Burchardi, H
Hedenstierna, G
机构
[1] Univ Gottingen, Dept Anesthesiol Emergency & Intens Care Med, D-37075 Gottingen, Germany
[2] Uppsala Univ, Dept Clin Physiol, Uppsala, Sweden
[3] Univ Bonn, Dept Anesthesiol & Intens Care Med, D-5300 Bonn, Germany
关键词
regional ventilation; thoracic electrical impedance tomography;
D O I
10.1378/chest.124.1.314
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: The validation of electrical impedance tomography (EIT) for measuring regional ventilation distribution by comparing it with single photon emission CT (SPECT) scanning. Design: Randomized, prospective animal study. Settings: Animal laboratories and nuclear medicine laboratories at a university hospital. Participants: Twelve anesthetized and mechanically ventilated pigs. Interventions: Lung injury was induced by central venous injection of oleic acid. Then pigs were randomized to pressure-controlled mechanical ventilation, airway pressure-release ventilation, or spontaneous breathing. Measurements and results: Ventilation distribution was assessed by EIT using cross-sectional electrotomographic measurements of the thorax, and simultaneously by single SPECT scanning with the inhalation of Tc-99m-labeled carbon particles. For both methods, the evaluation of ventilation distribution was performed in the same transverse slice that was approximately 4 cm in thickness. The transverse slice then was divided into 20 coronal segments (going from the sternum to the spine). We compared the percentage of ventilation in each segment, normalized to the entire ventilation in the observed slice. Our data showed an excellent linear correlation between the ventilation distribution measured by SPECT scanning and EIT according to the following equation: y = 0.82x + 0.7,(R-2 = 0.92; range, 0.86 to 0.97). Conclusion: Based on these data, EIT seems to allow, at least in comparable states of lung injury, real-time monitoring of regional ventilation distribution at the bedside.
引用
收藏
页码:314 / 322
页数:9
相关论文
共 50 条
  • [31] Assessment of regional ventilation with the electrical impedance tomography in a patient after asphyxial cardiac arrest
    Dostal, Pavel
    Truhlar, Anatolij
    Polak, Josef
    Sedlak, Vratislav
    Turek, Zdenek
    [J]. RESUSCITATION, 2014, 85 (08) : E115 - E117
  • [32] Regional Distribution of Ventilation Measured by Electrical Impedance Tomography (EIT) in Mechanically Ventilated Children
    Inany, H.
    Rettig, J.
    Smallwood, C.
    Walsh, B. K.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [33] Distribution of regional lung ventilation in upright healthy subjects determined by electrical impedance tomography
    Frerichs, Inez
    Vogt, Barbara
    Deuss, Kathinka
    Hennig, Victoria
    Strodthoff, Claas
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [34] Electrical Impedance Tomography and Ventilation Heterogeneity on a Silicosis Patient
    Beder, T. N.
    Takizawa, D. B.
    Quizhpe, P. J.
    Macedo, B. R.
    Garcia, M.
    Tucci, M. R.
    Costa, E. L. V.
    Amato, M. B. P.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [35] Electrical impedance tomography for lung ventilation monitoring of the dog
    Gloning, Simon
    Pieper, Korbinian
    Zoeliner, Martin
    Meyer-Lindenberg, Andrea
    [J]. TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2017, 45 (01): : 15 - 21
  • [36] Regional ventilation and perfusion assessed by electrical impedance imaging
    Newell, JC
    Isaacson, D
    Blue, RS
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 780 - 781
  • [37] Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study
    Richard, J. C.
    Pouzot, C.
    Gros, A.
    Tourevieille, C.
    Lebars, D.
    Lavenne, F.
    Frerichs, I.
    Guerin, C.
    [J]. CRITICAL CARE, 2009, 13 (03)
  • [38] Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study
    JC Richard
    C Pouzot
    A Gros
    C Tourevieille
    D Lebars
    F Lavenne
    I Frerichs
    C Guérin
    [J]. Critical Care, 13
  • [39] Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography
    Grant, Caroline A.
    Trang Pham
    Hough, Judith
    Riedel, Thomas
    Stocker, Christian
    Schibler, Andreas
    [J]. CRITICAL CARE, 2011, 15 (01):
  • [40] Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography
    Caroline A Grant
    Trang Pham
    Judith Hough
    Thomas Riedel
    Christian Stocker
    Andreas Schibler
    [J]. Critical Care, 15