Combination of conventional ultrasonography and virtual touch tissue imaging quantification for differential diagnosis of breast lesions smaller than 10mm

被引:10
|
作者
Zhang, Shu-Pin [3 ]
Zeng, Zeng [1 ,2 ]
Liu, Hui [1 ,2 ]
Yao, Ming-Hua [1 ,2 ]
Xu, Guang [1 ,2 ]
Wu, Rong [1 ,2 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Med Ultrasound, Shanghai, Peoples R China
[2] Tongji Univ, Sch Med, Ultrasound Res & Educ Inst, Shanghai, Peoples R China
[3] Shanghai First Peoples Hosp, Baoshan Branch, Dept Med Ultrasound, Shanghai, Peoples R China
关键词
Conventional ultrasonography; virtual touch tissue imaging quantification; breast lesions; SHEAR-WAVE ELASTOGRAPHY; FORCE IMPULSE TECHNOLOGY; ULTRASOUND ELASTOGRAPHY; SONOGRAPHY; BENIGN; MASSES; WOMEN; MAMMOGRAPHY; ELASTICITY;
D O I
10.3233/CH-170249
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To determine the value of combining conventional ultrasonography with virtual touch tissue imaging quantification (VTIQ) for differential diagnosis of breast lesions smaller than 10 mm. METHODS: A total of 98 breast lesions smaller than 10mm were examined by conventional ultrasound and VTIQ using a Siemens ACUSON S3000 ultrasound machine. Pathologic diagnosis was established after surgery or fine needle biopsy. RESULTS: Malignant lesions were characterized by taller-than-wide shape, poorly circumscribed margin, and marked hypoechogenicity. The mean VTIQ shear wave velocity (SWV) value of malignant lesions was 4.88 +/- 1.87 m/s (range, 1.75-9.34 m/s), significantly higher than that of benign lesions (2.68 +/- 1.02 m/s; range, 1.18-4.67 m/s). The optimal cutoff SWV value was 3.27 m/s, with sensitivity, specificity, diagnostic accuracy, positive predictive value (PPV), and negative predictive value (NPV) of 86.20%, 95.65%, 92.86%, 89.29%, and 94.29%, respectively. The combination of SWV >3.27 m/s plus the US feature of poorly circumscribed margin had the highest sensitivity (93.33%) and specificity (100%) for diagnosis of malignant breast lesions. CONCLUSION: Features such as taller-than-wide shape, poorly circumscribed margin, and marked hypoechogenicity on conventional US, and SWV >3.27 m/s on VTIQ, are indicators of malignancy in breast lesions with diameter <10 mm. The combination of poorly circumscribed margin and SWV >3.27 m/s provides the highest specificity and diagnostic accuracy.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 50 条
  • [31] Breast Imaging Reporting and Data System evaluation of breast lesions improved with virtual touch tissue imaging average grayscale values
    Lian, Weizhen
    Lian, Kaimei
    Lin, Teng
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (02) : 925 - 936
  • [32] Virtual Touch Tissue Imaging for Differential Diagnosis of Thyroid Nodules Additional Value of the Area Ratio
    Xu, Jun-Mei
    Xu, Hui-Xiong
    Zhang, Yi-Feng
    Guo, Le-Hang
    Liu, Lin-Na
    Bo, Xiao-Wan
    Xu, Xiao-Hong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (05) : 917 - 926
  • [33] CONVENTIONAL US AND 2-D SHEAR WAVE ELASTOGRAPHY OF VIRTUAL TOUCH TISSUE IMAGING QUANTIFICATION: CORRELATION WITH IMMUNOHISTOCHEMICAL SUBTYPES OF BREAST CANCER
    Liu, Hui
    Wan, Jing
    Xu, Guang
    Xiang, Li-Hua
    Fang, Yan
    Ding, Shi-Si
    Jiang, Xiao
    Sun, Li-Ping
    Zhang, Yi-Feng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (10): : 2612 - 2622
  • [34] Clinical value of virtual touch tissue imaging quantification in diagnosis and treatment of congenital muscular torticollis in children
    Luo, Hongxia
    Li, Tianran
    Wu, Senmin
    Zhu, Hui
    Chen, Kai
    Ma, Lie
    Lin, Miaomiao
    TRANSLATIONAL PEDIATRICS, 2020, 9 (01) : 13 - 20
  • [35] VALUE OF ULTRASONIC ELASTOGRAPHY AND CONVENTIONAL ULTRASONOGRAPHY IN THE DIFFERENTIAL DIAGNOSIS OF NON-MASS-LIKE BREAST LESIONS
    Qu, Xiao-xia
    Song, Yu
    Zhang, Yu-hong
    Qing, Hua-min
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (06): : 1358 - 1366
  • [36] Comparison of Virtual Touch Tissue Quantification with B-Mode Sonography in the Differential Diagnosis of Superficial Lymph Nodes
    Wu, Ying
    Bai, Min
    Gu, Jiying
    Li, Hongli
    Du, Lianfang
    Li, Fenghua
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (04) : 703 - 708
  • [37] Correlation of virtual touch tissue imaging quantification with the Nottingham prognostic index and immunohistochemical features in breast invasive carcinoma
    Han, Ting
    Wu, Rong
    Pu, Huan
    Yao, Ming-Hua
    Xu, Guang
    Liu, Hui
    Xiang, Li-Hua
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2018, 39 (05) : 727 - 732
  • [38] Evaluation of Virtual Touch Tissue Imaging Quantification, a New Shear Wave Velocity Imaging Method, for Breast Lesion Assessment by Ultrasound
    Golatta, Michael
    Schweitzer-Martin, Mirjam
    Harcos, Aba
    Schott, Sarah
    Gomez, Christina
    Stieber, Anne
    Rauch, Geraldine
    Domschke, Christoph
    Rom, Joachim
    Schuetz, Florian
    Sohn, Christof
    Heil, Joerg
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [39] Virtual touch imaging quantification shear-wave elastography for breast lesions: the diagnostic value of qualitative and quantitative features
    Luo, T.
    Zhang, J. W.
    Zhu, Y.
    Jia, X. H.
    Dong, Y. J.
    Zhan, W. W.
    Zhou, J. Q.
    CLINICAL RADIOLOGY, 2021, 76 (04) : 316.e1 - 316.e8
  • [40] Virtual Touch Tissue Quantification of Acoustic Radiation Force Impulse: A New Ultrasound Elastic Imaging in the Diagnosis of Thyroid Nodules
    Zhang, Yi-Feng
    Xu, Hui-Xiong
    He, Yong
    Liu, Chang
    Guo, Le-Hang
    Liu, Lin-Na
    Xu, Jun-Mei
    PLOS ONE, 2012, 7 (11):