Combination of conventional ultrasonography and virtual touch tissue imaging quantification for differential diagnosis of breast lesions smaller than 10mm

被引:10
|
作者
Zhang, Shu-Pin [3 ]
Zeng, Zeng [1 ,2 ]
Liu, Hui [1 ,2 ]
Yao, Ming-Hua [1 ,2 ]
Xu, Guang [1 ,2 ]
Wu, Rong [1 ,2 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Med Ultrasound, Shanghai, Peoples R China
[2] Tongji Univ, Sch Med, Ultrasound Res & Educ Inst, Shanghai, Peoples R China
[3] Shanghai First Peoples Hosp, Baoshan Branch, Dept Med Ultrasound, Shanghai, Peoples R China
关键词
Conventional ultrasonography; virtual touch tissue imaging quantification; breast lesions; SHEAR-WAVE ELASTOGRAPHY; FORCE IMPULSE TECHNOLOGY; ULTRASOUND ELASTOGRAPHY; SONOGRAPHY; BENIGN; MASSES; WOMEN; MAMMOGRAPHY; ELASTICITY;
D O I
10.3233/CH-170249
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To determine the value of combining conventional ultrasonography with virtual touch tissue imaging quantification (VTIQ) for differential diagnosis of breast lesions smaller than 10 mm. METHODS: A total of 98 breast lesions smaller than 10mm were examined by conventional ultrasound and VTIQ using a Siemens ACUSON S3000 ultrasound machine. Pathologic diagnosis was established after surgery or fine needle biopsy. RESULTS: Malignant lesions were characterized by taller-than-wide shape, poorly circumscribed margin, and marked hypoechogenicity. The mean VTIQ shear wave velocity (SWV) value of malignant lesions was 4.88 +/- 1.87 m/s (range, 1.75-9.34 m/s), significantly higher than that of benign lesions (2.68 +/- 1.02 m/s; range, 1.18-4.67 m/s). The optimal cutoff SWV value was 3.27 m/s, with sensitivity, specificity, diagnostic accuracy, positive predictive value (PPV), and negative predictive value (NPV) of 86.20%, 95.65%, 92.86%, 89.29%, and 94.29%, respectively. The combination of SWV >3.27 m/s plus the US feature of poorly circumscribed margin had the highest sensitivity (93.33%) and specificity (100%) for diagnosis of malignant breast lesions. CONCLUSION: Features such as taller-than-wide shape, poorly circumscribed margin, and marked hypoechogenicity on conventional US, and SWV >3.27 m/s on VTIQ, are indicators of malignancy in breast lesions with diameter <10 mm. The combination of poorly circumscribed margin and SWV >3.27 m/s provides the highest specificity and diagnostic accuracy.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 50 条
  • [21] The application of Virtual Touch tissue quantification (VTQ) in diagnosis of thyroid lesions: A preliminary study
    Hou, Xiu-Juan
    Sun, Ai-Xia
    Zhou, Xian-Li
    Ji, Qiao
    Wang, Hong-Bo
    Wei, Hong
    Sun, Jia-Wei
    Liu, Han
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : 797 - 801
  • [22] Comparison of Contrast-Enhanced Ultrasonography with Virtual Touch Tissue Quantification in the Evaluation of Focal Liver Lesions
    Wu, Jing-ping
    Shu, Rui
    Zhao, Yu-zhen
    Ma, Guo-lin
    Xue, Wei
    He, Qi-jia
    Hao, Mei-na
    Liu, Yawu
    JOURNAL OF CLINICAL ULTRASOUND, 2016, 44 (06) : 347 - 353
  • [23] Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjogren's Syndrome: A Preliminary Study
    Chen, Shaoqi
    Wang, Yukai
    Zhang, Guohong
    Chen, Shigao
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [24] Differential diagnosis of thyroid nodules with virtual touch tissue imaging of ARFI elastography
    Li, Tao
    Zhou, Pei
    Ding, Mingyue
    Mi, Yongwei
    Li, Yiyong
    Zhang, Ji
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [25] VALUE OF VIRTUAL TOUCH TISSUE IMAGING QUANTIFICATION FOR EVALUATION OF ULTRASOUND BREAST IMAGING-REPORTING AND DATA SYSTEM CATEGORY 4 LESIONS
    Li, Xiao-Long
    Xu, Hui-Xiong
    Bo, Xiao-Wan
    Liu, Bo-Ji
    Huang, Xian
    Li, Dan-Dan
    Guo, Le-Hang
    Xu, Jun-Mei
    Sun, Li-Ping
    Fang, Lin
    Xu, Xiao-Hong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (09): : 2050 - 2057
  • [26] Application of conventional ultrasound coupled with virtual touch tissue imaging and quantification in the assessment of muscle strength
    Zhou, Weichen
    Ma, Xiaojuan
    Pan, Lin
    Wang, Yunhan
    Zhou, Chengting
    ANNALS OF PALLIATIVE MEDICINE, 2020, 9 (05) : 3402 - 3409
  • [27] Color-map virtual touch tissue imaging (CMV) combined with BI-RADS for the diagnosis of breast lesions
    Lian, Kai-Mei
    Lin, Teng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (03) : 447 - 457
  • [28] SHEAR WAVE VELOCITY MEASUREMENTS FOR DIFFERENTIAL DIAGNOSIS OF SOLID BREAST MASSES: A COMPARISON BETWEEN VIRTUAL TOUCH QUANTIFICATION AND VIRTUAL TOUCH IQ
    Tozaki, Mitsuhiro
    Saito, Masahiro
    Benson, John
    Fan, Liexiang
    Isobe, Sachiko
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12): : 2233 - 2245
  • [29] Normal breast tissue stiffness measured by a new ultrasound technique: Virtual touch tissue imaging quantification (VTIQ)
    Golatta, Michael
    Schweitzer-Martin, Mirjam
    Harcos, Aba
    Schott, Sarah
    Junkermann, Hans
    Rauch, Geraldine
    Sohn, Christof
    Heil, Joerg
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E676 - E679
  • [30] Differential Diagnosis of Breast Lesions 5 mm or Less: Is There a Role for Magnetic Resonance Imaging?
    Dietzel, Matthias
    Baltzer, Pascal A.
    Vag, Tibor
    Groeschel, Tobias
    Gajda, Mieczyslaw
    Camara, Oumar
    Kaiser, Werner A.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (03) : 456 - 464