Combination of conventional ultrasonography and virtual touch tissue imaging quantification for differential diagnosis of breast lesions smaller than 10mm

被引:10
|
作者
Zhang, Shu-Pin [3 ]
Zeng, Zeng [1 ,2 ]
Liu, Hui [1 ,2 ]
Yao, Ming-Hua [1 ,2 ]
Xu, Guang [1 ,2 ]
Wu, Rong [1 ,2 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Med Ultrasound, Shanghai, Peoples R China
[2] Tongji Univ, Sch Med, Ultrasound Res & Educ Inst, Shanghai, Peoples R China
[3] Shanghai First Peoples Hosp, Baoshan Branch, Dept Med Ultrasound, Shanghai, Peoples R China
关键词
Conventional ultrasonography; virtual touch tissue imaging quantification; breast lesions; SHEAR-WAVE ELASTOGRAPHY; FORCE IMPULSE TECHNOLOGY; ULTRASOUND ELASTOGRAPHY; SONOGRAPHY; BENIGN; MASSES; WOMEN; MAMMOGRAPHY; ELASTICITY;
D O I
10.3233/CH-170249
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To determine the value of combining conventional ultrasonography with virtual touch tissue imaging quantification (VTIQ) for differential diagnosis of breast lesions smaller than 10 mm. METHODS: A total of 98 breast lesions smaller than 10mm were examined by conventional ultrasound and VTIQ using a Siemens ACUSON S3000 ultrasound machine. Pathologic diagnosis was established after surgery or fine needle biopsy. RESULTS: Malignant lesions were characterized by taller-than-wide shape, poorly circumscribed margin, and marked hypoechogenicity. The mean VTIQ shear wave velocity (SWV) value of malignant lesions was 4.88 +/- 1.87 m/s (range, 1.75-9.34 m/s), significantly higher than that of benign lesions (2.68 +/- 1.02 m/s; range, 1.18-4.67 m/s). The optimal cutoff SWV value was 3.27 m/s, with sensitivity, specificity, diagnostic accuracy, positive predictive value (PPV), and negative predictive value (NPV) of 86.20%, 95.65%, 92.86%, 89.29%, and 94.29%, respectively. The combination of SWV >3.27 m/s plus the US feature of poorly circumscribed margin had the highest sensitivity (93.33%) and specificity (100%) for diagnosis of malignant breast lesions. CONCLUSION: Features such as taller-than-wide shape, poorly circumscribed margin, and marked hypoechogenicity on conventional US, and SWV >3.27 m/s on VTIQ, are indicators of malignancy in breast lesions with diameter <10 mm. The combination of poorly circumscribed margin and SWV >3.27 m/s provides the highest specificity and diagnostic accuracy.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 50 条
  • [1] Combination of Virtual Touch Tissue Imaging and Virtual Touch Tissue Quantification for Differential Diagnosis of Breast Lesions
    Teke, Memik
    Goya, Cemil
    Teke, Fatma
    Uslukaya, Omer
    Hamidi, Cihad
    Cetincakmak, Mehmet Guli
    Hattapoglu, Salih
    Alan, Bircan
    Tekbas, Guven
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (07) : 1201 - 1208
  • [2] The value of virtual touch tissue imaging quantification in the differential diagnosis between benign and malignant breast lesions
    Kong, Wen-tao
    Zhou, Wei-jun
    Wang, Yin
    Zhuang, Xiao-min
    Wu, Min
    JOURNAL OF MEDICAL ULTRASONICS, 2019, 46 (04) : 459 - 466
  • [3] The value of virtual touch tissue imaging quantification in the differential diagnosis between benign and malignant breast lesions
    Wen-tao Kong
    Wei-jun Zhou
    Yin Wang
    Xiao-min Zhuang
    Min Wu
    Journal of Medical Ultrasonics, 2019, 46 : 459 - 466
  • [4] Combined Value of Virtual Touch Tissue Quantification and Conventional Sonographic Features for Differentiating Benign and Malignant Thyroid Nodules Smaller Than 10 mm
    Zhang, Huiping
    Shi, Qiusheng
    Gu, Jiying
    Jiang, Luying
    Bai, Min
    Liu, Long
    Wu, Ying
    Du, Lianfang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (02) : 257 - 264
  • [5] Applications of Mechanical Arm in the Virtual Touch Tissue Imaging Quantification and the Differential Diagnosis of Breast Tumors
    Li, Ling
    Lv, Guorong
    Shen, Haolin
    Liao, Liping
    Zhong, Rong
    Zheng, Chunnuan
    Yang, Shuping
    ULTRASOUND QUARTERLY, 2022, 38 (01) : 25 - 30
  • [6] Comparison of Virtual Touch Tissue Quantification and Virtual Touch Tissue Imaging Quantification for diagnosis of solid breast tumors of different sizes
    Chen, Ying-pei
    Han, Ting
    Wu, Rong
    Yao, Ming-hua
    Xu, Guang
    Zhao, Li-xia
    Liu, Hui
    Pu, Huan
    Fang, Yan
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 64 (02) : 235 - 244
  • [7] The predictive models based on multimodality ultrasonography for the differential diagnosis of thyroid nodules smaller than 10 mm
    Li, Gang
    Ma, Sai
    Zhang, Fan
    Jia, Chao
    Liu, Long
    Gao, Feng
    Shi, Qiusheng
    Wu, Rong
    Du, Lianfang
    Li, Fan
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1149):
  • [8] Comparison of Virtual Touch Tissue Imaging & Quantification (VTIQ) and Virtual Touch Tissue Quantification (VTQ) for diagnosis of thyroid nodules
    Yang, Yu-Ping
    Xu, Xiao-Hong
    Bo, Xiao-Wan
    Liu, Bo-Ji
    Guo, Le-Hang
    Xu, Jun-Mei
    Sun, Li-Ping
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 65 (02) : 137 - 149
  • [9] Role of strain elastography and virtual touch tissue quantification technique in the diagnosis of breast solid lesions
    Cheng, Lin
    Shang, Mengmeng
    Li, Jie
    Sun, Xiao
    Shi, Dandan
    Ning, Song
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (09): : 18754 - 18763
  • [10] Qualitative Evaluation of Virtual Touch Imaging Quantification: A Simple and Useful Method in the Diagnosis of Breast Lesions
    Zhu, Ying
    Jia, Xiao-hong
    Zhou, Wei
    Zhan, Wei-wei
    Zhou, Jian-qiao
    CANCER MANAGEMENT AND RESEARCH, 2020, 12 : 2037 - 2045