Interfraction physical dose variations in high-dose-rate brachytherapy for carcinoma cervix based on computed tomography image dataset to find the compatibility of the first fraction plan to treat successive fractions

被引:2
|
作者
Yadav, Suresh [1 ,3 ,4 ]
Singh, O. P. [1 ]
Choudhary, S. [3 ,4 ]
Saroj, Dinesh Kumar [2 ]
Maurya, Anil Kumar [5 ]
Yogi, Veenita [1 ]
机构
[1] Gandhi Med Coll, Dept Radiotherapy, Bhopal, India
[2] Chirayu Med Coll & Hosp, Dept Radiotherapy, Bhopal, India
[3] Rabindrzmath Tagore Univ, Dept Phys, Raisen, Madhya Pradesh, India
[4] AISECT Univ, Raisen, Madhya Pradesh, India
[5] Moti Lal Nehru Med Coll, Dept Radiotherapy, Allahabad, Uttar Pradesh, India
关键词
Image-based high-dose-rate brachytherapy; interfraction variation; physical dosimetric analysis; CANCER BRACHYTHERAPY; RECOMMENDATIONS; GUIDELINES; TERMS;
D O I
10.4103/jcrt.JCRT_475_19
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Context: Due to limited resources and/or affordability by majority of the patients, many centers in low- and middle-income countries are still not able to adapt three-dimensional image-based brachytherapy planning in their routine practice.Aim: The aim of the study was to see the feasibility of using computed tomography (CT)-based plan of the first fraction to treat successive fractions of intracavitary brachytherapy based on the estimation of the physical dosimetric differences between successive applications.Materials and Methods: CT image-based brachytherapy plans of 38 patients who received three insertions of intracavitary application with high-dose-rate brachytherapy have been analyzed. Revised plans for the second and third insertions were generated by adapting dwell time and dwell position of the first insertion plan. The dose to point "A" and maximum doses to 2, 1, and 0.1 cc volumes of the rectum and bladder have been used for dosimetric comparison.Results: The statistical differences of mean point "A" doses were observed insignificant except between original and revised plans for the second insertions. The dosimetric differences between consecutive original and revised plans for the bladder and rectum have not shown any significance except minimum dose to 0.1 cc volume of the rectum for the third insertions.Conclusions: Dosimetric deviation for tumor and organs at risk is within acceptable limit while using CT image-based brachytherapy plan of the first fraction for treating successive fractions.
引用
收藏
页码:1304 / 1308
页数:5
相关论文
共 46 条
  • [41] Pilot study in the treatment of endometrial carcinoma with 3D image based high-dose-rate brachytherapy using modified Heyman packing:: Clinical experience and dose-volume-histogram analysis
    Weitmann, H. D.
    Poetter, R.
    Waldhaeusl, C.
    Nechvile, E.
    Kirisits, Ch.
    Knocke, T. H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 197 - 197
  • [42] Clinical outcome after high dose rate intracavitary brachytherapy with traditional point 'A' dose prescription in locally advanced carcinoma of uterine cervix: dosimetric analysis from the perspective of computed tomography imaging-based 3-dimensional treatment planning
    Dhabal, Suman
    Basu, Abhishek
    Sau, Saikat
    Sau, Sourav
    Maiti, Pradip Kumar
    Chakravarty, Abhay
    OBSTETRICS & GYNECOLOGY SCIENCE, 2024, 67 (01) : 67 - 75
  • [43] Pilot study in the treatment of endometrial carcinoma with 3D image-based high-dose-rate brachytherapy using modified Heyman packing:: Clinical experience and dose-volume histogram analysis
    Weitmann, HD
    Pötter, R
    Waldhäusl, C
    Nechvile, E
    Kirisits, C
    Knocke, TH
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02): : 468 - 478
  • [44] Preliminary experience on the implementation of computed tomography (CT)-based image guided brachytherapy (IGBT) of cervical cancer using high-dose-rate (HDR) Cobalt-60 source in University of Malaya Medical Centre (UMMC)
    Jamalludin, Z.
    Min, U. N.
    Ishak, W. Z. Wan
    Malik, R. Abdul
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [45] Hepatocellular carcinoma: computed-tomography-guided high-dose-rate brachytherapy (CT-HDRBT) ablation of large (5-7 cm) and very large (>7 cm) tumours
    Collettini, Federico
    Schnapauff, Dirk
    Poellinger, Alexander
    Denecke, Timm
    Schott, Eckart
    Berg, Thomas
    Wust, Peter
    Hamm, Bernd
    Gebauer, Bernhard
    EUROPEAN RADIOLOGY, 2012, 22 (05) : 1101 - 1109
  • [46] Dosimetry and plan parameters study of three-dimensional-printed template-based intra-cavitary/ interstitial interpolation technology using computed tomography-guided high-dose-rate brachytherapy in locally advanced cervical cancer
    Liu, Baoxi
    Wu, Yaqin
    Sun, Li
    Guo, Chang
    Wang, Qi
    Mu, Zhongde
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (05) : 325 - 333