Interfraction physical dose variations in high-dose-rate brachytherapy for carcinoma cervix based on computed tomography image dataset to find the compatibility of the first fraction plan to treat successive fractions

被引:2
|
作者
Yadav, Suresh [1 ,3 ,4 ]
Singh, O. P. [1 ]
Choudhary, S. [3 ,4 ]
Saroj, Dinesh Kumar [2 ]
Maurya, Anil Kumar [5 ]
Yogi, Veenita [1 ]
机构
[1] Gandhi Med Coll, Dept Radiotherapy, Bhopal, India
[2] Chirayu Med Coll & Hosp, Dept Radiotherapy, Bhopal, India
[3] Rabindrzmath Tagore Univ, Dept Phys, Raisen, Madhya Pradesh, India
[4] AISECT Univ, Raisen, Madhya Pradesh, India
[5] Moti Lal Nehru Med Coll, Dept Radiotherapy, Allahabad, Uttar Pradesh, India
关键词
Image-based high-dose-rate brachytherapy; interfraction variation; physical dosimetric analysis; CANCER BRACHYTHERAPY; RECOMMENDATIONS; GUIDELINES; TERMS;
D O I
10.4103/jcrt.JCRT_475_19
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Context: Due to limited resources and/or affordability by majority of the patients, many centers in low- and middle-income countries are still not able to adapt three-dimensional image-based brachytherapy planning in their routine practice.Aim: The aim of the study was to see the feasibility of using computed tomography (CT)-based plan of the first fraction to treat successive fractions of intracavitary brachytherapy based on the estimation of the physical dosimetric differences between successive applications.Materials and Methods: CT image-based brachytherapy plans of 38 patients who received three insertions of intracavitary application with high-dose-rate brachytherapy have been analyzed. Revised plans for the second and third insertions were generated by adapting dwell time and dwell position of the first insertion plan. The dose to point "A" and maximum doses to 2, 1, and 0.1 cc volumes of the rectum and bladder have been used for dosimetric comparison.Results: The statistical differences of mean point "A" doses were observed insignificant except between original and revised plans for the second insertions. The dosimetric differences between consecutive original and revised plans for the bladder and rectum have not shown any significance except minimum dose to 0.1 cc volume of the rectum for the third insertions.Conclusions: Dosimetric deviation for tumor and organs at risk is within acceptable limit while using CT image-based brachytherapy plan of the first fraction for treating successive fractions.
引用
收藏
页码:1304 / 1308
页数:5
相关论文
共 46 条
  • [21] Parallelized patient-specific quality assurance for high-dose-rate image-guided brachytherapy in an integrated computed tomography-on-rails brachytherapy suite
    Kim, Taeho
    Showalter, Timothy N.
    Watkins, W. Tyler
    Trifiletti, Daniel M.
    Libby, Bruce
    BRACHYTHERAPY, 2015, 14 (06) : 834 - 839
  • [22] Estimation and comparison of integral dose to target and organs at risk in three-dimensional computed tomography image-based treatment planning of carcinoma uterine cervix with two high-dose-rate brachytherapy sources: 60Co and 192Ir
    Yadav, Suresh
    Singh, O. P.
    Choudhary, S.
    Saroj, Dinesh Kumar
    Yogi, Veenita
    Goswami, Brijesh
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (01) : 191 - 197
  • [23] Measurement of craniocaudal catheter displacement between fractions in computed tomography-based high dose rate brachytherapy of prostate cancer
    Kim, Yongbok
    Hsu, I-Chow J.
    Pouliot, Jean
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (04): : 1 - 13
  • [24] Image-guided cervix high-dose-rate brachytherapy treatment planning: Does custom computed tomography planning for each insertion provide better conformal avoidance of organs at risk?
    Davidson, Melanie T. M.
    Yuen, Jasper
    D'Souza, David P.
    Batchelar, Deidre L.
    BRACHYTHERAPY, 2008, 7 (01) : 37 - 42
  • [25] End-to-end delivery quality assurance of computed tomography-based high-dose-rate brachytherapy using a gel dosimeter
    Tachibana, Hidenobu
    Watanabe, Yusuke
    Mizukami, Shinya
    Maeyama, Takuya
    Terazaki, Tsuyoshi
    Uehara, Ryuzo
    Akimoto, Tetsuo
    BRACHYTHERAPY, 2020, 19 (03) : 362 - 371
  • [26] The usefulness of an independent patient-specific treatment planning verification method using a benchmark plan in high-dose-rate intracavitary brachytherapy for carcinoma of the uterine cervix
    Takahashi, Yutaka
    Koizumi, Masahiko
    Sumida, Iori
    Isohashi, Fumiaki
    Ogata, Toshiyuki
    Akino, Yuichi
    Yoshioka, Yasuo
    Maruoka, Shintaro
    Inoue, Shinichi
    Konishi, Koji
    Ogawa, Kazuhiko
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (06) : 936 - 944
  • [27] Use of Functional Magnetic Resonance Imaging in Cervical Cancer Patients With Incomplete Response on Positron Emission Tomography/Computed Tomography After Image-Based High-Dose-Rate Brachytherapy
    Kalash, Ronny
    Glaser, Scott M.
    Rangaswamy, Balasubramanya
    Horne, Zachary D.
    Kim, Hayeon
    Houser, Christopher
    Beriwal, Sushil
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (04): : 1008 - 1013
  • [28] An early report on outcomes from computed tomographic-based high-dose-rate brachytherapy for locally advanced cervix cancer: A single institution experience
    Hallock, Abhirami
    Surry, Kathleen
    Batchelar, Deidre
    VanderSpek, Lauren
    Yuen, Jasper
    Hammond, Alex
    Radwan, John
    Yaremko, Brian
    Rodrigues, George
    D'Souza, David
    PRACTICAL RADIATION ONCOLOGY, 2011, 1 (03) : 173 - 181
  • [29] Effectiveness and safety of computed tomography-guided high-dose-rate brachytherapy in treating recurrent hepatocellular carcinoma not amenable to repeated resection or radiofrequency ablation
    Auer, Timo Alexander
    Anhamm, Melina
    Boening, Georg
    Fehrenbach, Uli
    Schoening, Wenzel
    Lurje, Georg
    Gebauer, Bernhard
    Collettini, Federico
    EJSO, 2024, 50 (07):
  • [30] Modeling normal tissue complication probability from repetitive computed tomography scans during fractionated high-dose-rate brachytherapy and external beam radiotherapy of the uterine cervix
    Dale, E
    Hellebust, TP
    Skjonsberg, A
    Hogberg, T
    Olsen, DR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04): : 963 - 971