Development and characterization of a neutron tomography system based on image intensifier CCD system

被引:9
|
作者
Sinha, A [1 ]
Shaikh, AM
Shyam, A
机构
[1] Bhabha Atom Res Ctr, High Pressure Phys Div, Purnima Lab, Mumbai 400085, India
[2] Bhabha Atom Res Ctr, Div Solid State Phys, Mumbai 400085, India
关键词
neutron tomography; CCD; image intensifier; CBP method;
D O I
10.1016/S0168-583X(98)00263-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A neutron tomography system has been developed using a low cost electronic imaging system which uses commercially available Image intensifrer, CCD, Frame grabber. This setup has been used for a series of experiments on neutron tomography at the 400 kW swimming pool type reactor APSARA which has a neutron flux of 10(6) n/cm(2)/s at L/D = 90. The main feature of this tomography system is integrated computer controlled imaging and stepper motor control system with online data acquisition, analysis and display of images for each projection angle. The density profile of the projection images and ray sum calculation can be carried out in offline or online manner at any slice and a series of reconstructed image for any slice can be obtained. An algorithm for reconstruction using Convolution Back Projection (CBP) technique has been developed and implemented on a Pentium system. The imaging system is modular in design. The reconstructed image has shown good quality and holes of less than 0.6 mm filled with wax can be revealed in a 60 mm aluminum matrix or 1 mm holes in 40 mm solid brass matrix have been resolved. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [31] A CCD-BASED IMAGE RECORDING-SYSTEM FOR THE CTEM
    ROBERTS, PTE
    CHAPMAN, JN
    MACLEOD, AM
    ULTRAMICROSCOPY, 1982, 8 (04) : 385 - 396
  • [32] Based on line scan CCD print image detection system
    Zhang, Lifeng
    Xie, Kai
    Li, Tong
    MIPPR 2015: PATTERN RECOGNITION AND COMPUTER VISION, 2015, 9813
  • [33] Testing method of plate level based on CCD image system
    Zeng, Ai-Jun
    He, Ping-An
    Yu, Chang-Ming
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2001, 12 (10): : 1048 - 1050
  • [34] Development of high frame rate CCD image remote acquisition system
    Zhang, Haibing
    Li, Binkang
    Ruan, Linbo
    Feng, Bing
    Guo, Mingan
    27TH INTERNATIONAL CONGRESS ON HIGH SPEED PHOTOGRAPHY AND PHOTONICS, PRTS 1-3, 2007, 6279
  • [35] An RFQ accelerator based neutron radiography and tomography system
    Lanza, RC
    Fink, DW
    Iverson, EB
    McFarland, EW
    Shi, S
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 347 - 350
  • [36] VMEBUS SYSTEM FOR CCD IMAGE ACQUISITION
    BONANNO, G
    FEDEL, B
    DANTIOCHIA, M
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1992, 104 (682) : 1252 - 1255
  • [37] Progressive scan CCD image system
    Lin, Jiaming
    Yang, Yingqiu
    Guangxue Jishu/Optical Technique, 1997, (06): : 43 - 45
  • [38] DEVELOPMENT OF THE OPTICAL TRANSFER FUNCTION (OTF) FOR IMAGE INTENSIFIED CCD, PARTICULARLY WITH OTF OF IMAGE INTENSIFIER TUBES (IIT)
    Gul, Nebi
    Efe, Murat
    Larochelle, Vincent
    2008 IEEE 25TH CONVENTION OF ELECTRICAL AND ELECTRONICS ENGINEERS IN ISRAEL, VOLS 1 AND 2, 2008, : 36 - +
  • [39] Development of a neutron tomography system using a low flux reactor
    Hungler, P. C.
    Bennett, L. G. I.
    Lewis, W. J.
    Bevan, G. A.
    Gabov, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 651 (01): : 81 - 85
  • [40] Development of three dimensional neutron tomography system and its applications
    Sinha, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03): : 1455 - 1459