Development and characterization of a neutron tomography system based on image intensifier CCD system

被引:9
|
作者
Sinha, A [1 ]
Shaikh, AM
Shyam, A
机构
[1] Bhabha Atom Res Ctr, High Pressure Phys Div, Purnima Lab, Mumbai 400085, India
[2] Bhabha Atom Res Ctr, Div Solid State Phys, Mumbai 400085, India
关键词
neutron tomography; CCD; image intensifier; CBP method;
D O I
10.1016/S0168-583X(98)00263-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A neutron tomography system has been developed using a low cost electronic imaging system which uses commercially available Image intensifrer, CCD, Frame grabber. This setup has been used for a series of experiments on neutron tomography at the 400 kW swimming pool type reactor APSARA which has a neutron flux of 10(6) n/cm(2)/s at L/D = 90. The main feature of this tomography system is integrated computer controlled imaging and stepper motor control system with online data acquisition, analysis and display of images for each projection angle. The density profile of the projection images and ray sum calculation can be carried out in offline or online manner at any slice and a series of reconstructed image for any slice can be obtained. An algorithm for reconstruction using Convolution Back Projection (CBP) technique has been developed and implemented on a Pentium system. The imaging system is modular in design. The reconstructed image has shown good quality and holes of less than 0.6 mm filled with wax can be revealed in a 60 mm aluminum matrix or 1 mm holes in 40 mm solid brass matrix have been resolved. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [21] An image intensifier-based volume tomographic angiography imaging system
    Ning, RL
    Wang, XH
    Conover, DL
    Tang, XY
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 238 - 246
  • [23] A system for the automatic inspection of image intensifier tubes
    Sartor, M
    Pecina, J
    Paul, C
    Helms, B
    Alsman, D
    VISUAL INFORMATION PROCESSING V, 1996, 2753 : 110 - 121
  • [24] An image data acquisition system based on area CCD
    Wang, ZQ
    Xie, MJ
    Su, WX
    Wang, CX
    Zhao, Y
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 528 - 530
  • [25] A cooled CCD based neutron imaging system for low fluence neutron sources
    Lanza, RC
    Shi, S
    McFarland, EW
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 390 - 394
  • [26] Study on CCD Measurement System based on Image Processing
    Zhao, Wenhui
    Duan, Zhenyun
    Zhao, Ping
    Zhao, Wenzhen
    MATERIALS PROCESSING TECHNOLOGY II, PTS 1-4, 2012, 538-541 : 2143 - 2146
  • [27] A cooled CCD based neutron imaging system for low fluence neutron sources
    Lanza, RC
    Shi, S
    McFarland, EW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1347 - 1351
  • [28] Analysis of background component introduced by mirror in neutron radiography CCD image system
    Li H.
    Liu Y.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (02): : 406 - 410
  • [29] Development of a GaAs-based neutron tomography system for the assay of nuclear fuel
    Sanders, JD
    Lindsay, JT
    McGregor, DS
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2326 - 2329
  • [30] Development of a pulsed neutron three-dimensional imaging system using a highly sensitive image-intensifier at J-PARC
    Segawa, M.
    Ooi, M.
    Kai, T.
    Shinohara, T.
    Kureta, M.
    Sakamoto, K.
    Imaki, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 769 : 97 - 104