Development and characterization of a neutron tomography system based on image intensifier CCD system

被引:9
|
作者
Sinha, A [1 ]
Shaikh, AM
Shyam, A
机构
[1] Bhabha Atom Res Ctr, High Pressure Phys Div, Purnima Lab, Mumbai 400085, India
[2] Bhabha Atom Res Ctr, Div Solid State Phys, Mumbai 400085, India
关键词
neutron tomography; CCD; image intensifier; CBP method;
D O I
10.1016/S0168-583X(98)00263-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A neutron tomography system has been developed using a low cost electronic imaging system which uses commercially available Image intensifrer, CCD, Frame grabber. This setup has been used for a series of experiments on neutron tomography at the 400 kW swimming pool type reactor APSARA which has a neutron flux of 10(6) n/cm(2)/s at L/D = 90. The main feature of this tomography system is integrated computer controlled imaging and stepper motor control system with online data acquisition, analysis and display of images for each projection angle. The density profile of the projection images and ray sum calculation can be carried out in offline or online manner at any slice and a series of reconstructed image for any slice can be obtained. An algorithm for reconstruction using Convolution Back Projection (CBP) technique has been developed and implemented on a Pentium system. The imaging system is modular in design. The reconstructed image has shown good quality and holes of less than 0.6 mm filled with wax can be revealed in a 60 mm aluminum matrix or 1 mm holes in 40 mm solid brass matrix have been resolved. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [1] DIGITAL READOUT SYSTEM FOR STREAK CAMERAS ON THE BASIS OF CCD AND IMAGE INTENSIFIER
    VYSOGORETS, MV
    EREMENKO, BM
    LOZOVOY, VI
    MECHETIN, AM
    PETROV, MY
    PLATONOV, VN
    POSTOVALOV, VE
    PROKHOROV, AM
    SCHELEV, MY
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 702 - 705
  • [2] Development and characterization of a neutron tomography system for a Research Reactor
    Abd el Bar, Waleed
    Mahmoud, Imbaby I.
    Konber, Hussein A.
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2016, 10 (02): : 195 - 204
  • [3] Performance and calibration of a neutron image intensifier tube based real-time radiography system
    Deinert, MR
    Lowe, CW
    Parlange, JY
    Ünlü, K
    Cady, KB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 349 - 355
  • [4] FAST IMAGE INTENSIFIER SYSTEM
    BARRAULT, MR
    KEKEZ, MM
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (12): : 1041 - &
  • [5] Development of Neutron Color Image Intensifier for Pulsed Neutron Source
    Nittoh, Koichi
    Konagai, Chikara
    Yahagi, Mitsuru
    Kiyanagi, Yoshiaki
    Kamiyama, Takashi
    PROCEEDINGS OF THE 10TH WORLD CONFERENCE ON NEUTRON RADIOGRAPHY (WCNR-10), 2015, 69 : 177 - 184
  • [6] Research on digitally integrated test system for performance evaluation of image intensifier and intensified CCD
    Wang, X
    Jin, WQ
    Gao, ZY
    Wang, ZH
    Bai, TZ
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150
  • [7] Development of a system for neutron radiography and tomography
    Mühlbauer, MJ
    Calzada, E
    Schillinger, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 542 (1-3): : 324 - 328
  • [8] Computed tomography with image intensifier: Imaging and characterization of materials
    Department of Physics, Sir C.R.R. Autonomous College, Eluru-534007, W.G. Dt., A.P., India
    不详
    不详
    Nucl Instrum Methods Phys Res Sect A, 1 (141-151):
  • [9] Computed tomography with image intensifier: imaging and characterization of materials
    Rao, DV
    Cesareo, R
    Brunetti, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 437 (01): : 141 - 151
  • [10] A physical image quality evaluation of a CCD-based X-ray image intensifier digital fluorography system for cardiac applications
    Baker, EL
    Cowen, AR
    Kemner, R
    Bastiaens, R
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 430 - 441