Potentiometric biosensor for lysine analysis based on a chemically immobilized lysine oxidase membrane

被引:32
|
作者
Saurina, J
Hernández-Cassou, S
Fàbregas, E
Alegret, S
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
[2] Univ Autonoma Barcelona, Dept Chem, E-08193 Barcelona, Spain
关键词
potentiometric lysine biosensor; immobilized lysine oxidase membranes; all-solid-state ammonium electrode; lysine analysis;
D O I
10.1016/S0003-2670(98)00310-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzymatic lysine electrode is developed for the potentiometric analysis of lysine (Lys). This lysine biosensor consists of a chemically immobilized lysine oxidase membrane attached to an all-solid-state ammonium electrode. In this system, the enzymatic degradation of lysine produces ammonia, which is then detected with the ammonium electrode. The influence of immobilization conditions on the potentiometric response and the lifetime of the electrode was studied. Under optimal conditions, the relationship between the potentiometric response and the log [Lys] was linear between 3x10(-5) and 10(-3) M, the sensitivity was 50 mV/decade, the repeatability 1.4%, and the response time t(95%) was 15 s. (C) 1998 Elsevier Science B.V, All rights reserved.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [21] APPLICATION OF IMMOBILIZED LYSINE DECARBOXYLASE TUBES FOR AUTOMATED-ANALYSIS OF L-LYSINE
    TANAKA, A
    HAGI, N
    ITOH, N
    FUKUI, S
    JOURNAL OF FERMENTATION TECHNOLOGY, 1980, 58 (04): : 391 - 394
  • [22] Studies on dynamic behavior of the biosensor based on immobilized glucoamylase glucose oxidase membrane
    Gondo, S
    Kim, C
    Hirata, S
    Morishita, M
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (05): : 395 - 401
  • [23] An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane
    Zaide Zhou
    Lina Qiao
    Peng Zhang
    Dan Xiao
    Martin M. F. Choi
    Analytical and Bioanalytical Chemistry, 2005, 383 : 673 - 679
  • [24] Analysis of diazinon pesticide using potentiometric biosensor based on enzyme immobilized cellulose acetate membrane in gold electrode
    Mashuni
    Ramadhan, L. O. A. N.
    Jahiding, M.
    Herniati
    10TH JOINT CONFERENCE ON CHEMISTRY, 2016, 107
  • [25] An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane
    Zhou, ZD
    Qiao, L
    Zhang, P
    Xiao, D
    Choi, MMF
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (04) : 673 - 679
  • [26] Flow injection analysis system for L-lysine estimation in foodstuffs using a biosensor based on lysine oxidase immobilization on a gold-poly(m-phenylenediamine) electrode
    Divritsioti, MH
    Karalemas, ID
    Georgiou, CA
    Papastathopoulos, DS
    ANALYTICAL LETTERS, 2003, 36 (09) : 1939 - 1963
  • [27] Biosensor for detection of hypoxanthine based on xanthine oxidase immobilized on chemically modified carbon paste electrode
    Hu, SS
    Xu, CL
    Luo, JH
    Luo, J
    Cui, DF
    ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) : 55 - 61
  • [28] A novel approach for the selective analysis of L-lysine in untreated human serum by a co-crosslinked L-lysine-α-oxidase/overoxidized polypyrrole bilayer based amperometric biosensor
    Ciriello, Rosanna
    De Gennaro, Francesca
    Frascaro, Silvio
    Guerrieri, Antonio
    BIOELECTROCHEMISTRY, 2018, 124 : 47 - 56
  • [29] Improved biosensor for glucose based on glucose oxidase-immobilized silk fibroin membrane
    Yu-Qing Zhang
    Jiang Zhu
    Ren-Ao Gu
    Applied Biochemistry and Biotechnology, 1998, 75 : 215 - 233
  • [30] Improved biosensor for glucose based on glucose oxidase-immobilized silk fibroin membrane
    Zhang, YQ
    Zhu, J
    Gu, RA
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1998, 75 (2-3) : 215 - 233