Flow injection analysis system for L-lysine estimation in foodstuffs using a biosensor based on lysine oxidase immobilization on a gold-poly(m-phenylenediamine) electrode

被引:15
|
作者
Divritsioti, MH
Karalemas, ID
Georgiou, CA
Papastathopoulos, DS [1 ]
机构
[1] Univ Athens, Dept Chem, Analyt Chem Lab, GR-15771 Athens, Greece
[2] Agr Univ Athens, Chem Lab, Athens, Greece
关键词
flow injection analysis; lysine biosensor; electropolymerization; m-phenylenediamine; lysine oxidase immobilization;
D O I
10.1081/AL-120023623
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and the evaluation of an amperometric FIA bio-sensing system for L-lysine determination in foodstuffs is described. The system employs a home-made flow-cell with an amperometric biosensor, prepared by immobilization of lysine oxidase on a gold-poly(m-phenylenediamine) electrode. A peristaltic pump is connected to the flow-cell via a 2-position 6-port sample injector/switching valve for the on-line transfer of the samples. The analytical procedure is based on the oxidation of L-lysine by L-lysine alpha-oxidase. The produced H2O2 is monitored amperometrically at 650 mV in FIA set-up. The lysine biosensor construction procedure comprises: a) the electropolymerization of m-phenylenediamine on a Si-gold strip electrode and b) the immobilization Of L-lysine a-oxidase on the poly(m-phenylenediamine) membrane with glutaraldehyde in the presence of bovine serum albumin. Parameters, such as, flow rate, enzyme amount, monomer concentration, matrix effect, effect of interference's, etc., were studied. The flow-cell biosensor system provides a linear response from 1 x 10(-3) to 5 x 10(-5) M of lysine, with excellent characteristics of reproducibility, stability, and life-time. The system was further applied and evaluated for the estimation of lysine in various hydrolysate food samples (e.g., pasta, milk, wheat flour, etc.) without any pretreatment with an average recovery of 97.3%.
引用
收藏
页码:1939 / 1963
页数:25
相关论文
共 15 条
  • [1] Construction of a L-lysine biosensor by immobilizing lysine oxidase on a gold-poly(o-phenylenediamine) electrode
    Karalemas, ID
    Georgiou, CA
    Papastathopoulos, DS
    TALANTA, 2000, 53 (02) : 391 - 402
  • [2] FLOW-INJECTION AMPEROMETRIC BIOSENSOR BASED ON IMMOBILIZED L-LYSINE-ALPHA-OXIDASE FOR L-LYSINE DETERMINATION
    SIMONIAN, AL
    BADALIAN, IE
    BEREZOV, TT
    SMIRNOVA, IP
    KHADUEV, SH
    ANALYTICAL LETTERS, 1994, 27 (15) : 2849 - 2860
  • [3] CHEMILUMINOMETRIC L-LYSINE DETERMINATION WITH IMMOBILIZED LYSINE OXIDASE BY FLOW-INJECTION ANALYSIS
    PREUSCHOFF, F
    SPOHN, U
    WEBER, E
    UNVERHAU, K
    MOHR, KH
    ANALYTICA CHIMICA ACTA, 1993, 280 (02) : 185 - 189
  • [4] Immobilization of Glucose Oxidase on a Poly(dimethylsiloxane) Layer by Using Poly(L-lysine) as a Polymer Backbone
    Yasukawa, Tomoyuki
    Maekawa, Eiji
    Mizutani, Fumio
    ANALYTICAL SCIENCES, 2009, 25 (09) : 1159 - 1162
  • [5] Immobilization of Glucose Oxidase on a Poly(dimethylsiloxane) Layer by Using Poly(l-lysine) as a Polymer Backbone
    Tomoyuki Yasukawa
    Eiji Maekawa
    Fumio Mizutani
    Analytical Sciences, 2009, 25 : 1159 - 1162
  • [6] The kinetic and analytical behaviours of an L-lysine amperometric biosensor based on lysine oxidase immobilised onto a platinum electrode by co-crosslinking
    Guerrieri, Antonio
    Cataldi, Tornmaso R. I.
    Ciriello, Rosanna
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 126 (02) : 424 - 430
  • [7] Selective biosensing of L-lysine by a low-temperature flow-injection technique using an immobilized lysine oxidase reactor
    Chen, RLC
    Lee, MH
    Matsumoto, K
    ANALYTICAL SCIENCES, 1996, 12 (01) : 87 - 90
  • [8] Fabrication of chronocoulometric DNA sensor based on gold nanoparticles/poly(L-lysine) modified glassy carbon electrode
    Wang, Jie
    Zhang, Shaojun
    Zhang, Yuzhong
    ANALYTICAL BIOCHEMISTRY, 2010, 396 (02) : 304 - 309
  • [9] A novel approach for the selective analysis of L-lysine in untreated human serum by a co-crosslinked L-lysine-α-oxidase/overoxidized polypyrrole bilayer based amperometric biosensor
    Ciriello, Rosanna
    De Gennaro, Francesca
    Frascaro, Silvio
    Guerrieri, Antonio
    BIOELECTROCHEMISTRY, 2018, 124 : 47 - 56
  • [10] L-GLUTAMATE BIOSENSOR USING A NOVEL L-GLUTAMATE OXIDASE AND ITS APPLICATION TO FLOW-INJECTION ANALYSIS SYSTEM
    YE, BC
    LI, QS
    LI, YR
    LI, XB
    YU, JT
    JOURNAL OF BIOTECHNOLOGY, 1995, 42 (01) : 45 - 52