Dynamic behavior of DFIG-based wind turbines during grid faults

被引:0
|
作者
Erlich, I. [1 ]
Wrede, H. [2 ]
Feltes, C. [1 ]
机构
[1] Univ Duisburg Essen, D-47057 Duisburg, Germany
[2] SEG GmbH & Co, D-47906 Kempen, Germany
关键词
wind turbine; doubly-fed induction; generator; fault-ride through;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
According to grid codes issued by utilities, tripping of wind turbines following grid faults is not allowed. Besides, to provide voltage support to the grid mandatory reactive current supply is necessary. To enable wind turbines ride-through low voltage periods special protection measures have to be implemented. In this paper the behavior of DFIG based wind turbines during grid faults is discussed and elucidated using simulation results. It is shown that with properly designed crowbar and DC-link chopper even zero voltage ride-through is possible.
引用
下载
收藏
页码:1162 / +
页数:2
相关论文
共 50 条
  • [21] Detailed Investigation and Performance Improvement of the Dynamic Behavior of Grid-Connected DFIG-Based Wind Turbines Under LVRT Conditions
    Alsmadi, Yazan M.
    Xu, Longya
    Blaabjerg, Frede
    Ortega, Alejandro J. Pina
    Abdelaziz, Almoataz Y.
    Wang, Aimeng
    Albataineh, Zaid
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (05) : 4795 - 4812
  • [22] Dynamic Performance Evaluation of DFIG-based Wind Turbines regarding new German Grid Code Requirements
    Feltes, C.
    Engelhardt, S.
    Kretschmann, J.
    Fortmann, J.
    Erlich, I.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [23] Enhancement of Dynamic Modeling for LVRT Capability in DFIG-Based Wind Turbines
    M. Kenan Döşoğlu
    Iranian Journal of Science and Technology, Transactions of Electrical Engineering, 2020, 44 : 1345 - 1356
  • [24] Analyzing the Dynamic Behavior of a DFIG-based Wind Farm under Sudden Grid Disturbances
    Chakraborty, A.
    Kumar, S.
    Tudu, B.
    Mandal, K. K.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INTELLIGENT SUSTAINABLE SYSTEMS (ICISS 2017), 2017, : 336 - 341
  • [25] Virtual Synchronous Control of Grid-Connected DFIG-based Wind Turbines
    Zhao, Yangyang
    Chai, Jianyun
    Sun, Xudong
    2015 THIRTIETH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2015), 2015, : 2980 - 2983
  • [26] Synchronizing Stability of DFIG-based Wind Turbines Attached to Weak AC Grid
    Hu, Qi
    Hu, Jiabing
    Yuan, Hao
    Tang, Haiyan
    Li, Yan
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 2618 - 2624
  • [27] Coupling DFIG-Based Wind Turbines with the Grid under Voltage Imbalance Conditions
    Sobhy, Ahmed
    Abo-Khalil, Ahmed G.
    Lei, Dong
    Salameh, Tareq
    Merabet, Adel
    Alkasrawi, Malek
    SUSTAINABILITY, 2022, 14 (09)
  • [28] Stability Analysis of DFIG-based Wind Turbines Based on Hybrid Control in Weak Grid
    Xie Z.
    Xu K.
    Gao X.
    Yang S.
    Zhang X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (20): : 7426 - 7438
  • [29] Simulation of Faults in DFIG-Based Wind Farms
    Mahadanaarachchi, Viraj Pradeep
    Ramakumar, Rama
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 5228 - 5235
  • [30] Virtual Capacitance Control for Improving Dynamic Stability of the DFIG-Based Wind Turbines During a Symmetrical Fault in a Weak AC Grid
    Sun, Peng
    Yao, Jun
    Liu, Ruikuo
    Pei, Jinxin
    Zhang, Hailin
    Liu, Yuan
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (01) : 333 - 346