Isotope ratios on transient signals with GC-MC-ICP-MS

被引:45
|
作者
Krupp, EA [1 ]
Donard, OFX [1 ]
机构
[1] LCABIE, CNRS, F-64053 Pau, France
关键词
MC-ICP-MS; gas chromatography; transient signals; isotope ratios;
D O I
10.1016/j.ijms.2004.11.026
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
ICP-MS instruments with multiple ion collectors (MC-ICP-MS) provide highly precise and accurate isotope ratio measurements. These instruments are easily coupled to chromatography, laser ablation or flow injection devices because of the ICP source, and thus attract general analytical interest for measurement of highly precise element isotope ratios on transient signals. Some few papers have been published today where MC-ICP-MS was employed for isotope ratios on transient signals, and in general, results are encouraging. Isotope ratio precision obtained is usually at least 10-fold superior compared to measurements with ICP-QMS. Nevertheless, most authors describe a drift of isotope ratios during the transient peak. This behaviour was either interpreted as a problem in the sample introduction system, or was related to instrumental mass bias drift, but has to date not been completely evaluated or explained. In this paper, we systematically investigate the drift observed on lead and mercury isotopes during short transient signals obtained from GC coupled to different MC-ICP-MS systems. We can clearly show that neither changes in instrumental mass bias, nor chromatographic fractionation effects are the source of the observed isotope ratio drift. An influence of analyte concentration on the observed drift was as well excluded as a source for this drift, because the slope on isotope ratios show the same values for different concentrations evaluated. In contrast, the peak width was found to influence the extent to which the isotope ratio drifts during peak elution. Thus, the relative intensity change per time seems to be an important factor for the measurements of transient signals with MC-ICP-MS. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 242
页数:10
相关论文
共 50 条
  • [21] Analysis of high-precision vanadium isotope ratios by medium resolution MC-ICP-MS
    Nielsen, Sune G.
    Owens, Jeremy D.
    Horner, Tristan J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (02) : 531 - 536
  • [22] Uranium isotope ratios determined by MC-ICP-MS and the assessment of total combined uncertainty budgets
    Boulyga, S. F.
    Kloetzli, U.
    Prohaska, T.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A113 - A113
  • [23] Cadmium Isotope Ratios of Standard Solutions and Geological Reference Materials Measured by MC-ICP-MS
    Li, Dandan
    Li, Meng-Lun
    Liu, Wen-Ran
    Qin, Zhen-Zhen
    Liu, Sheng-Ao
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2018, 42 (04) : 593 - 605
  • [24] In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS
    Kaufmann, A. B.
    Lazarov, M.
    Kiefer, S.
    Majzlan, J.
    Weyer, S.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (07) : 1554 - 1567
  • [25] Lithium isotope analysis on the Neoma MS/MS MC-ICP-MS
    Scott, Sean R.
    Turner, Gabrielle L.
    Gartman, Brandy N.
    Anguiano, Sonia Alcantar
    Melby, Kali M.
    Allen, Barbara E.
    Minton, Travis D.
    Risenhuber, Matthew A.
    Hobbs, Kirby P.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (04) : 1098 - 1105
  • [26] Determination of compound-specific Hg isotope ratios from transient signals using gas chromatography coupled to multicollector inductively coupled plasma mass spectrometry (MC-ICP/MS)
    Dzurko, Mark
    Foucher, Delphine
    Hintelmann, Holger
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) : 345 - 355
  • [27] Determination of compound-specific Hg isotope ratios from transient signals using gas chromatography coupled to multicollector inductively coupled plasma mass spectrometry (MC-ICP/MS)
    Mark Dzurko
    Delphine Foucher
    Holger Hintelmann
    Analytical and Bioanalytical Chemistry, 2009, 393
  • [28] Accurate measurements of Th-U isotope ratios for carbonate geochronology using MC-ICP-MS
    Seth, B
    Thirlwall, MF
    Houghton, SL
    Craig, CA
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (11) : 1323 - 1330
  • [29] A novel approach to sample preparation for the analysis of Sb isotope ratios in natural water by MC-ICP-MS
    Xia, Yi
    Deng, Qianwen
    Sun, Guangyi
    Wu, Yunjie
    Qiao, Shengying
    Ali, Jamshed
    Fu, Xuewu
    Feng, Xinbin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (02) : 359 - 368
  • [30] In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Zhang, Yan
    Peng, Deyi
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (08) : 2021 - 2029