Isotope ratios on transient signals with GC-MC-ICP-MS

被引:45
|
作者
Krupp, EA [1 ]
Donard, OFX [1 ]
机构
[1] LCABIE, CNRS, F-64053 Pau, France
关键词
MC-ICP-MS; gas chromatography; transient signals; isotope ratios;
D O I
10.1016/j.ijms.2004.11.026
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
ICP-MS instruments with multiple ion collectors (MC-ICP-MS) provide highly precise and accurate isotope ratio measurements. These instruments are easily coupled to chromatography, laser ablation or flow injection devices because of the ICP source, and thus attract general analytical interest for measurement of highly precise element isotope ratios on transient signals. Some few papers have been published today where MC-ICP-MS was employed for isotope ratios on transient signals, and in general, results are encouraging. Isotope ratio precision obtained is usually at least 10-fold superior compared to measurements with ICP-QMS. Nevertheless, most authors describe a drift of isotope ratios during the transient peak. This behaviour was either interpreted as a problem in the sample introduction system, or was related to instrumental mass bias drift, but has to date not been completely evaluated or explained. In this paper, we systematically investigate the drift observed on lead and mercury isotopes during short transient signals obtained from GC coupled to different MC-ICP-MS systems. We can clearly show that neither changes in instrumental mass bias, nor chromatographic fractionation effects are the source of the observed isotope ratio drift. An influence of analyte concentration on the observed drift was as well excluded as a source for this drift, because the slope on isotope ratios show the same values for different concentrations evaluated. In contrast, the peak width was found to influence the extent to which the isotope ratio drifts during peak elution. Thus, the relative intensity change per time seems to be an important factor for the measurements of transient signals with MC-ICP-MS. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 242
页数:10
相关论文
共 50 条
  • [1] Isotope ratio determination of antimony from the transient signal of trimethylstibine by GC-MC-ICP-MS and GC-ICP-TOF-MS
    Wehmeier, S
    Ellam, R
    Feldmann, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) : 1001 - 1007
  • [2] Measurement of isotope ratios on transient signals by MC-ICP–MS
    Ines Günther-Leopold
    Beat Wernli
    Zlatko Kopajtic
    Detlef Günther
    Analytical and Bioanalytical Chemistry, 2004, 378 : 241 - 249
  • [3] Measurement of isotope ratios on transient signals by MC-ICP-MS
    Günther-Leopold, I
    Wernli, B
    Kopajtic, Z
    Günther, D
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) : 241 - 249
  • [4] Development of the high presicion measurement of mercury species isotopic ratios by GC-MC-ICP-MS and its validation with two other analytical aproaches
    Epov, V. N.
    Rodriguez-Gonzalez, P.
    Sonke, J.
    Tessier, E.
    Amouroux, D.
    Maurice Bourgoin, L.
    Estrade, N.
    Carignan, J.
    Donard, O. F. X.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A258 - A258
  • [5] Isotope ratio measurements on transient signals by an online coupled HPLC-MC-ICP-MS system
    Günther-Leopold, I
    Wernli, B
    Kopajtic, Z
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A297 - A297
  • [6] Analysis of Sr and Pb isotope ratios in wine by MC-ICP-MS
    Xie, Q.
    Hassan, N.
    Hintelmann, H.
    Evans, D.
    Dillon, P.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A1044 - A1044
  • [7] U and Pb isotope ratios in manganese nodules by MC-ICP-MS
    Ehrlich, S
    Bar-Matthews, M
    Harlavan, Y
    Halicz, L
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A209 - A209
  • [8] Determination of europium isotope ratios in natural waters by MC-ICP-MS
    Arantes de Carvalho, Gabriel Gustinelli
    Oliveira, Pedro Vitoriano
    Yang, Lu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (05) : 987 - 995
  • [9] Accuracy and long-term precision of MC-ICP-MS isotope ratios
    Thirlwall, M
    Ancziewicz, R
    Vance, D
    Munday, D
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A771 - A771
  • [10] ANALYSIS OF TITANIUM ISOTOPE RATIOS IN REFRACTORY INCLUSIONS BY LA-MC-ICP-MS
    Williams, C. D.
    Wadhwa, M.
    Janney, P. E.
    Hines, R. R.
    Bullock, E. S.
    MacPherson, G. J.
    METEORITICS & PLANETARY SCIENCE, 2011, 46 : A250 - A250