Determination of europium isotope ratios in natural waters by MC-ICP-MS

被引:0
|
作者
Arantes de Carvalho, Gabriel Gustinelli [1 ,2 ]
Oliveira, Pedro Vitoriano [2 ]
Yang, Lu [1 ]
机构
[1] Natl Res Council Canada, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
[2] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, Av Prof Lineu Prestes 748, BR-05513970 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
RARE-EARTH-ELEMENTS; MASS-SPECTROMETRY; ACCURATE DETERMINATION; SILICATE ROCKS; CHROMATOGRAPHY; SAMPLES; EXTRACTION; PRECISE; SEPARATION; ND-143/ND-144;
D O I
10.1039/c7ja00020k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical protocol for the accurate and precise determination of the europium isotope ratio in low level natural waters is presented for the first time by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Parameters affecting the separation of Eu from the matrix by employing a single-step column separation with di(2-ethylhexyl) orthophosphoric acid (HDEHP) resin were investigated in detail. Matrix elements (e.g., alkali, alkali-earth and transition metals) were efficiently removed and Eu was quantitatively separated from other rare earth elements (REEs) by sequential elution using gradient HCl concentrations (from 0.25 to 0.75 mol L-1). Fractionation of Eu isotopes in the column was not observed, since quantitative europium recovery (101.2 +/- 0.5% mean and 1 SD, n = 3) was obtained (data based on 150 mL SLRS-6 river water CRM test portions spiked with 1.0 ng mL(-1) Eu standard solution). A combined standard-sample bracketing with internal normalization method was employed for the mass bias correction, wherein Gd was added to both the sample and standard as an internal standard. The developed method was validated by processing 0.02 ng mL(-1) Eu spiked river water CRM SLRS-6 (wherein Eu was removed first by using the above-mentioned column separation method) using the proposed method, and satisfying results (delta Eu-151/153 value of 0.01 +/- 0.02 parts per thousand; 1 SD) relative to Eu standard solution were obtained. No significant differences were found in the delta Eu-151/153 values in river water SLRS-6, drinking water AQUA-1 and collected groundwater samples from Brazil, which ranged from -0.07 +/- 0.02 to 0.12 +/- 0.24 (mean +/- 1 SD, n = 5).
引用
收藏
页码:987 / 995
页数:9
相关论文
共 50 条
  • [1] Measurement of isotope ratios on transient signals by MC-ICP-MS
    Günther-Leopold, I
    Wernli, B
    Kopajtic, Z
    Günther, D
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) : 241 - 249
  • [2] High precision determination of chromium isotope ratios in geological samples by MC-ICP-MS
    Halicz, Ludwik
    Yang, Lu
    Teplyakov, Nataliya
    Burg, Avihu
    Sturgeon, Ralph
    Kolodny, Yehoshua
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (12) : 1622 - 1627
  • [3] High precision determination of silver isotope ratios in commercial products by MC-ICP-MS
    Yang, Lu
    Dabek-Zlotorzynska, Ewa
    Celo, Valbona
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) : 1564 - 1569
  • [4] Analysis of Sr and Pb isotope ratios in wine by MC-ICP-MS
    Xie, Q.
    Hassan, N.
    Hintelmann, H.
    Evans, D.
    Dillon, P.
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A1044 - A1044
  • [5] U and Pb isotope ratios in manganese nodules by MC-ICP-MS
    Ehrlich, S
    Bar-Matthews, M
    Harlavan, Y
    Halicz, L
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A209 - A209
  • [6] Accuracy and long-term precision of MC-ICP-MS isotope ratios
    Thirlwall, M
    Ancziewicz, R
    Vance, D
    Munday, D
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A771 - A771
  • [7] A novel approach to sample preparation for the analysis of Sb isotope ratios in natural water by MC-ICP-MS
    Xia, Yi
    Deng, Qianwen
    Sun, Guangyi
    Wu, Yunjie
    Qiao, Shengying
    Ali, Jamshed
    Fu, Xuewu
    Feng, Xinbin
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (02) : 359 - 368
  • [8] ACCURATE AND PRECISE DETERMINATION OF ISOTOPIC RATIOS BY MC-ICP-MS: A REVIEW
    Yang, Lu
    [J]. MASS SPECTROMETRY REVIEWS, 2009, 28 (06) : 990 - 1011
  • [9] Vanadium isotope measurement by MC-ICP-MS
    Wu, Fei
    Qi, Yuhan
    Yu, Huimin
    Tian, Shengyu
    Hou, Zhenhui
    Huang, Fang
    [J]. CHEMICAL GEOLOGY, 2016, 421 : 17 - 25
  • [10] Measurement of sulfur isotope ratios in trace amounts of dissolved sulfate by MC-ICP-MS
    Moon, Jonghan
    Joo, Young Ji
    Kang, Jung Ok
    Sim, Min Sub
    [J]. JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2021, 57 (01) : 99 - 108