Determination of europium isotope ratios in natural waters by MC-ICP-MS

被引:0
|
作者
Arantes de Carvalho, Gabriel Gustinelli [1 ,2 ]
Oliveira, Pedro Vitoriano [2 ]
Yang, Lu [1 ]
机构
[1] Natl Res Council Canada, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
[2] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, Av Prof Lineu Prestes 748, BR-05513970 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
RARE-EARTH-ELEMENTS; MASS-SPECTROMETRY; ACCURATE DETERMINATION; SILICATE ROCKS; CHROMATOGRAPHY; SAMPLES; EXTRACTION; PRECISE; SEPARATION; ND-143/ND-144;
D O I
10.1039/c7ja00020k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical protocol for the accurate and precise determination of the europium isotope ratio in low level natural waters is presented for the first time by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Parameters affecting the separation of Eu from the matrix by employing a single-step column separation with di(2-ethylhexyl) orthophosphoric acid (HDEHP) resin were investigated in detail. Matrix elements (e.g., alkali, alkali-earth and transition metals) were efficiently removed and Eu was quantitatively separated from other rare earth elements (REEs) by sequential elution using gradient HCl concentrations (from 0.25 to 0.75 mol L-1). Fractionation of Eu isotopes in the column was not observed, since quantitative europium recovery (101.2 +/- 0.5% mean and 1 SD, n = 3) was obtained (data based on 150 mL SLRS-6 river water CRM test portions spiked with 1.0 ng mL(-1) Eu standard solution). A combined standard-sample bracketing with internal normalization method was employed for the mass bias correction, wherein Gd was added to both the sample and standard as an internal standard. The developed method was validated by processing 0.02 ng mL(-1) Eu spiked river water CRM SLRS-6 (wherein Eu was removed first by using the above-mentioned column separation method) using the proposed method, and satisfying results (delta Eu-151/153 value of 0.01 +/- 0.02 parts per thousand; 1 SD) relative to Eu standard solution were obtained. No significant differences were found in the delta Eu-151/153 values in river water SLRS-6, drinking water AQUA-1 and collected groundwater samples from Brazil, which ranged from -0.07 +/- 0.02 to 0.12 +/- 0.24 (mean +/- 1 SD, n = 5).
引用
收藏
页码:987 / 995
页数:9
相关论文
共 50 条
  • [31] A Review of Mg Isotope Analytical Methods by MC-ICP-MS
    An, Yajun
    Huang, Fang
    JOURNAL OF EARTH SCIENCE, 2014, 25 (05) : 822 - 840
  • [32] A review of Mg isotope analytical methods by MC-ICP-MS
    Yajun An
    Fang Huang
    Journal of Earth Science, 2014, 25 : 822 - 840
  • [34] Optimisation of a current generation ICP-QMS and benchmarking against MC-ICP-MS spectrometry for the determination of lead isotope ratios in environmental samples
    Usman, Abida
    Ander, E. Louise
    Bailey, Elizabeth H.
    Nelms, Simon
    Pashley, Vanessa
    Young, Scott D.
    Chenery, Simon R.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (12) : 2184 - 2194
  • [35] Optimizing MC-ICP-MS with SEM protocols for determination of U and Th isotope ratios and 230Th ages in carbonates
    Chiang, Hong-Wei
    Lu, Yanbin
    Wang, Xianfeng
    Lin, Ke
    Liu, Xiaokang
    QUATERNARY GEOCHRONOLOGY, 2019, 50 : 75 - 90
  • [36] Rapid, simultaneous separation of Sr, Pb, and Nd by extraction chromatography prior to isotope ratios determination by TIMS and MC-ICP-MS
    Pin, Christian
    Gannoun, Abdelmouhcine
    Dupont, Alain
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (10) : 1858 - 1870
  • [37] Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
    Guo, Chao
    Li, Tao
    Li, Gaojun
    Chen, Tianyu
    Li, Le
    Zhao, Liang
    Ji, Junfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2470 - 2479
  • [38] Comparison and influence of 1011 and 1013 ohm resistors used for MC-ICP-MS determination of isotope ratios in highly enriched silicon
    Pramann, Axel
    Rienitz, Olaf
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (06) : 1540 - 1550
  • [39] Accurate measurements of Th-U isotope ratios for carbonate geochronology using MC-ICP-MS
    Seth, B. (b.seth@gl.rhul.ac.uk), 1600, Royal Society of Chemistry (18):
  • [40] Simultaneous measurement of lithium isotope and lithium/beryllium ratios in FLiBe salts using MC-ICP-MS
    Scott, Sean R.
    Carotti, Francesco
    Kruizenga, Alan
    Scarlat, Raluca O.
    Mastromarino, Sara
    Shafer, Martin M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (06) : 1193 - 1202