Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imaging

被引:37
|
作者
Sundareswaran, Kartik S. [1 ,2 ]
Haggerty, Christopher M. [1 ,2 ]
de Zelicourt, Diane [1 ,2 ]
Dasi, Lakshmi P. [3 ]
Pekkan, Kerem [4 ]
Frakes, David H. [5 ]
Powell, Andrew J. [6 ,7 ]
Kanter, Kirk R. [8 ]
Fogel, Mark A. [9 ]
Yoganathan, Ajit P. [1 ,2 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Emory Univ, Atlanta, GA 30332 USA
[3] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80523 USA
[4] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15213 USA
[5] Arizona State Univ, Sch Biol & Hlth Syst Engn, Tempe, AZ USA
[6] Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[7] Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USA
[8] Emory Univ, Sch Med, Div Pediat Cardiothorac Surg, Atlanta, GA USA
[9] Childrens Hosp Philadelphia, Div Pediat Cardiol, Philadelphia, PA 19104 USA
来源
基金
美国国家科学基金会;
关键词
TOTAL CAVOPULMONARY CONNECTION; COMPUTATIONAL FLUID-DYNAMICS; INTERPOLATION; INTRAATRIAL;
D O I
10.1016/j.jtcvs.2011.09.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Our objective was to analyze 3-dimensional (3D) blood flow patterns within the total cavopulmonary connection (TCPC) using in vivo phase contrast magnetic resonance imaging (PC MRI). Methods: Sixteen single-ventricle patients were prospectively recruited at 2 leading pediatric institutions for PC MRI evaluation of their Fontan pathway. Patients were divided into 2 groups. Group 1 comprised 8 patients with an extracardiac (EC) TCPC, and group 2 comprised 8 patients with a lateral tunnel (LT) TCPC. A coronal stack of 5 to 10 contiguous PC MRI slices with 3D velocity encoding (5-9 ms resolution) was acquired and a volumetric flow field was reconstructed. Results: Analysis revealed large vortices in LT TCPCs and helical flow structures in EC TCPCs. On average, there was no difference between LT and EC TCPCs in the proportion of inferior vena cava flow going to the left pulmonary artery (43% +/- 7% vs 46% +/- 5%; P = .34). However, for EC TCPCs, the presence of a caval offset was a primary determinant of inferior vena caval flow distribution to the pulmonary arteries with a significant bias to the offset side. Conclusions: 3D flow structures within LT and EC TCPCs were reconstructed and analyzed for the first time using PC MRI. TCPC flow patterns were shown to be different, not only on the basis of LT or EC considerations, but with significant influence from the superior vena cava connection as well. This work adds to the ongoing body of research demonstrating the impact of TCPC geometry on the overall hemodynamic profile. (J Thorac Cardiovasc Surg 2012; 143: 1108-16)
引用
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [41] Measurement of cerebral blood flow using phase contrast magnetic resonance imaging and duplex ultrasonography
    Khan, Muhammad Ayaz
    Liu, Jie
    Tarumi, Takashi
    Lawley, Justin Stevan
    Liu, Peiying
    Zhu, David C.
    Lu, Hanzhang
    Zhang, Rong
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (02): : 541 - 549
  • [42] Extension of rapid phase-contrast magnetic resonance imaging using BRISK in multidirectional flow
    Hershey, BL
    Doyle, M
    Kortright, E
    More, R
    Rayarao, G
    Anayiotos, A
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (07) : 929 - 936
  • [43] 3-DIMENSIONAL PHASE-CONTRAST IMAGING BY AN ANNULAR ILLUMINATION MICROSCOPE
    NODA, T
    KAWATA, S
    MINAMI, S
    APPLIED OPTICS, 1990, 29 (26): : 3810 - 3815
  • [44] Pulsatile cerebrospinal fluid flow measurement using phase-contrast magnetic resonance imaging in patients with cervical myelopathy
    Shibuya, R
    Yonenobu, K
    Koizumi, T
    Kato, Y
    Mitta, M
    Yoshikawa, H
    SPINE, 2002, 27 (10) : 1087 - 1093
  • [45] THE VISUALIZATION OF ROTATION IN DIAGRAMS OF 3-DIMENSIONAL STRUCTURES
    SEDDON, GM
    ENIAIYEJU, PA
    JUSOH, I
    AMERICAN EDUCATIONAL RESEARCH JOURNAL, 1984, 21 (01) : 25 - 38
  • [46] Three-Dimensional Visualization of Flow Characteristics Using a Magnetic Resonance Imaging in a Lattice Cooling Channel
    Tsuru, Tomoko
    Ishida, Katsuhiko
    Fujita, Junya
    Takeishi, Kenichiro
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2019, 141 (06):
  • [47] New insights in the Fontan circulation: 4-dimensional respiratory- and ECG-triggered phase contrast magnetic resonance imaging
    Christopher Hart
    Dominik Daniel Gabbert
    Inga Voges
    Michael Jerosch-Herold
    Ana Andrade
    Minh Pham
    Traudel Hansen
    Hans-Heiner Kramer
    Carsten Rickers
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [48] Visualization of the Lenticulostriate artery with 3-dimensional time-of-flight magnetic resonance angiography combined with the compressed sensing technique using a 3-T magnetic resonance imaging system
    Huang, Fuling
    Guo, Yurong
    Chen, Ruchang
    Lin, Shengcai
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 38 - 42
  • [49] 3-DIMENSIONAL ANISOTROPY CONTRAST MAGNETIC-RESONANCE-IMAGING OF THE RAT NERVOUS-SYSTEM - MR AXONOGRAPHY
    NAKADA, T
    MATSUZAWA, H
    NEUROSCIENCE RESEARCH, 1995, 22 (04) : 389 - 398
  • [50] Complications After Liver Transplantation: Evaluation With Magnetic Resonance Imaging, Magnetic Resonance Cholangiography, and 3-Dimensional Contrast-Enhanced Magnetic Resonance Angiography in a Single Session
    Boraschi, Piero
    Donati, Francescamaria
    Gigoni, Roberto
    Salemi, Simonetta
    Urbani, Lucio
    Filipponi, Franco
    Falaschi, Fabio
    Bartolozzi, Carlo
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2008, 59 (05): : 259 - 263