Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imaging

被引:37
|
作者
Sundareswaran, Kartik S. [1 ,2 ]
Haggerty, Christopher M. [1 ,2 ]
de Zelicourt, Diane [1 ,2 ]
Dasi, Lakshmi P. [3 ]
Pekkan, Kerem [4 ]
Frakes, David H. [5 ]
Powell, Andrew J. [6 ,7 ]
Kanter, Kirk R. [8 ]
Fogel, Mark A. [9 ]
Yoganathan, Ajit P. [1 ,2 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Emory Univ, Atlanta, GA 30332 USA
[3] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80523 USA
[4] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15213 USA
[5] Arizona State Univ, Sch Biol & Hlth Syst Engn, Tempe, AZ USA
[6] Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[7] Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USA
[8] Emory Univ, Sch Med, Div Pediat Cardiothorac Surg, Atlanta, GA USA
[9] Childrens Hosp Philadelphia, Div Pediat Cardiol, Philadelphia, PA 19104 USA
来源
基金
美国国家科学基金会;
关键词
TOTAL CAVOPULMONARY CONNECTION; COMPUTATIONAL FLUID-DYNAMICS; INTERPOLATION; INTRAATRIAL;
D O I
10.1016/j.jtcvs.2011.09.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Our objective was to analyze 3-dimensional (3D) blood flow patterns within the total cavopulmonary connection (TCPC) using in vivo phase contrast magnetic resonance imaging (PC MRI). Methods: Sixteen single-ventricle patients were prospectively recruited at 2 leading pediatric institutions for PC MRI evaluation of their Fontan pathway. Patients were divided into 2 groups. Group 1 comprised 8 patients with an extracardiac (EC) TCPC, and group 2 comprised 8 patients with a lateral tunnel (LT) TCPC. A coronal stack of 5 to 10 contiguous PC MRI slices with 3D velocity encoding (5-9 ms resolution) was acquired and a volumetric flow field was reconstructed. Results: Analysis revealed large vortices in LT TCPCs and helical flow structures in EC TCPCs. On average, there was no difference between LT and EC TCPCs in the proportion of inferior vena cava flow going to the left pulmonary artery (43% +/- 7% vs 46% +/- 5%; P = .34). However, for EC TCPCs, the presence of a caval offset was a primary determinant of inferior vena caval flow distribution to the pulmonary arteries with a significant bias to the offset side. Conclusions: 3D flow structures within LT and EC TCPCs were reconstructed and analyzed for the first time using PC MRI. TCPC flow patterns were shown to be different, not only on the basis of LT or EC considerations, but with significant influence from the superior vena cava connection as well. This work adds to the ongoing body of research demonstrating the impact of TCPC geometry on the overall hemodynamic profile. (J Thorac Cardiovasc Surg 2012; 143: 1108-16)
引用
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [21] MAGNETIC-RESONANCE ANGIOGRAPHY OF ABDOMINAL VESSELS - EARLY EXPERIENCE USING THE 3-DIMENSIONAL PHASE-CONTRAST TECHNIQUE
    VOCK, P
    TERRIER, F
    WEGMULLER, H
    MAHLER, F
    GERTSCH, P
    SOUZA, SP
    DUMOULIN, CL
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (757): : 10 - 16
  • [22] Characteristics of Intra-Left Atrial Flow Dynamics and Factors Affecting Formation of the Vortex Flow - Analysis With Phase-Resolved 3-Dimensional Cine Phase Contrast Magnetic Resonance Imaging
    Suwa, Kenichiro
    Saitoh, Takeji
    Takehara, Yasuo
    Sano, Makoto
    Nobuhara, Mamoru
    Saotome, Masao
    Urushida, Tsuyoshi
    Katoh, Hideki
    Satoh, Hiroshi
    Sugiyama, Masataka
    Wakayama, Tetsuya
    Alley, Marcus
    Sakahara, Harumi
    Hayashi, Hideharu
    CIRCULATION JOURNAL, 2015, 79 (01) : 144 - 152
  • [23] VISUALIZATION OF PARTICLES IN A 3-DIMENSIONAL FLOW
    MITGAU, PM
    HILLER, WJ
    KOWALEWSKI, TA
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1994, 74 (05): : T394 - T396
  • [24] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING OF A LIQUID FOAM
    PRAUSE, BA
    GLAZIER, JA
    GRAVINA, SJ
    MONTEMAGNO, CD
    JOURNAL OF PHYSICS-CONDENSED MATTER, 1995, 7 (40) : L511 - L516
  • [25] VASCULAR MORPHOLOGY BY 3-DIMENSIONAL MAGNETIC-RESONANCE IMAGING
    CLINE, HE
    LORENSEN, WE
    HERFKENS, RJ
    JOHNSON, GA
    GLOVER, GH
    MAGNETIC RESONANCE IMAGING, 1989, 7 (01) : 45 - 54
  • [26] Normal Three-Dimensional Pulmonary Artery Flow Determined by Phase Contrast Magnetic Resonance Imaging
    Victoria L. Morgan
    Robert J. Roselli
    Christine H. Lorenz
    Annals of Biomedical Engineering, 1998, 26 : 557 - 566
  • [27] Phase contrast flow imaging in Cardiac Magnetic Resonance (CMR): Imaging turbulent blood flow
    Chris B Lawton
    Stephen Lyen
    Jonathan C Rodrigues
    Nathan E Manghat
    Chiara Bucciarelli-Ducci
    Mark Hamilton
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [28] Normal three-dimensional pulmonary artery flow determined by phase contrast magnetic resonance imaging
    Morgan, VL
    Roselli, RJ
    Lorenz, CH
    ANNALS OF BIOMEDICAL ENGINEERING, 1998, 26 (04) : 557 - 566
  • [29] DIAGNOSIS OF SUPERIOR SAGITTAL SINUS THROMBOSIS BY 3-DIMENSIONAL MAGNETIC-RESONANCE FLOW IMAGING
    VILLRINGER, A
    SEIDERER, M
    BAUER, WM
    LAUB, G
    HABERL, RL
    EINHAUPL, KM
    LANCET, 1989, 1 (8646): : 1086 - 1087
  • [30] Quantifying and visualizing abdominal hemodynamics in patients with Fontan circulation by 4D phase-contrast flow magnetic resonance imaging at 1.5 T
    Ravesh, Mona Salehi
    Langguth, Patrick
    Moritz, Joerg Detlev
    Rinne, Katy
    Harneit, Paul Lennard
    Schulze-Nagel, Juliane
    Graessner, Joachim
    Uebing, Anselm
    Jansen, Olav
    Both, Marcus
    Hansen, Jan Hinnerk
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 413