Odour discrimination from wastewater treatment plants with a portable electronic nose

被引:5
|
作者
Lozano, Jesus [1 ]
Martin de la Vega, Pedro
Martinez, Enrique
Alvarez, Fernando [1 ]
Morera, Jorge [1 ]
Aguilera, Teodoro [1 ]
机构
[1] Univ Extremadura, Grp Invest Sistemas Sensoriales, E-06071 Badajoz, Spain
关键词
D O I
10.3303/CET1023028
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A home-made and home-developed electronic nose based on a non-specific array of tin oxide sensors was built in order to discriminate among odors from wastewater treatment plants. The prototype uses headspace sampling system: The headspace of samples of water stored in 15 ml vials is carried out to the sensors cell using an integrated pump controlled by the PC. It also uses and integrated multisensor in silicon composed by six tin oxide gas sensors with different geometries and operating at different temperatures between 400 and 500 degrees C. The measurement system is based on an USB data acquisition card and an electronic card designed for this application and controlled by pc with a program executed on it. The sensor responses from the six sensor array were stored on the PC and preprocessed for further analysis. Later, linear methods like PCA and non linear ones like Artificial Neural Networks were used to chech the discrimination capability of the system.. Different samples of water polluted by several typical contaminants have been used to evaluated the performance of the sensory system. Other set of samples coming from different stages of a wastewater treatment plants has been also measured. Results show a complete discrimination in PCA plot and a success rate near to 100% is obtained with Artificial Neural Networks in the Classification of Samples.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [21] Integrated Odour Management at Western Australian Wastewater Treatment Plants
    Wallis, I.
    Oma, R.
    [J]. WATER PRACTICE AND TECHNOLOGY, 2009, 4 (02):
  • [22] New compact scrubber for odour removal in wastewater treatment plants
    Sanchez, C.
    Couvert, A.
    Laplanche, A.
    Renner, C.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2006, 54 (09) : 45 - 52
  • [23] Tool for Predicting and Monitoring the Impact of Wastewater Treatment Plants on Odour
    Noe, I. Ho Tin
    Siino, F.
    Bara, C.
    Urvoy, Y.
    Haaser, C.
    Tripathi, A.
    Hamou, L. Ait
    Mailliard, T.
    [J]. NOSE 2010: INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ODOUR MONITORING AND CONTROL, 2010, 23 : 267 - 272
  • [24] Discrimination of selected fungi species based on their odour profile using prototypes of electronic nose instruments
    Gebicki, Jacek
    Szulczynski, Bartosz
    [J]. MEASUREMENT, 2018, 116 : 307 - 313
  • [25] Learning rules for odour recognition in an electronic nose
    McCoy, SA
    Martin, TP
    Baldwin, JF
    [J]. INTERNATIONAL JOURNAL OF UNCERTAINTY FUZZINESS AND KNOWLEDGE-BASED SYSTEMS, 2003, 11 (05) : 517 - 543
  • [26] Bluetooth electronic nose for odour monitoring and control
    Suárez J.I.
    Lozano J.
    Arroyo P.
    Herrero J.L.
    Carmona P.
    [J]. Lozano, Jesús (jesuslozano@unex.es), 2018, Italian Association of Chemical Engineering - AIDIC (68): : 211 - 216
  • [27] Control of odour emission in wastewater treatment plants by direct and undirected measurement of odour emission capacity
    Zarra, T.
    Giuliani, S.
    Naddeo, V.
    Belgiorno, V.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2012, 66 (08) : 1627 - 1633
  • [28] Electronic nose - an instrument for odour nuisances monitoring
    Szulczynski, Bartosz
    Gebicki, Jacek
    [J]. 11TH CONFERENCE ON INTERDISCIPLINARY PROBLEMS IN ENVIRONMENTAL PROTECTION AND ENGINEERING (EKO-DOK 2019), 2019, 100
  • [29] Experimental use of electronic nose for odour detection
    Sharma, Vishal
    Panchariya, P. C.
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING SYSTEMS MODELLING AND SIMULATION, 2015, 7 (04) : 238 - 243
  • [30] Development of an Electronic Nose for Environmental Odour Monitoring
    Dentoni, Licinia
    Capelli, Laura
    Sironi, Selena
    Del Rosso, Renato
    Zanetti, Sonia
    Della Torre, Matteo
    [J]. SENSORS, 2012, 12 (11) : 14363 - 14381