Optimum control of the hemopump as a left-ventricular assist device

被引:11
|
作者
He, P [1 ]
Bai, J
Xia, DD
机构
[1] Wright State Univ, Dept Biomed Ind & Human Factors Engn, Dayton, OH 45435 USA
[2] Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
hemopump; ischaemia; left-ventricular assist device; optimum control;
D O I
10.1007/BF02345135
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A general framework for designing an optimum control strategy for the Hemopump is described. An objective function was defined that includes four membership functions, each constructed based on the desired values of one of the four members: stroke volume, mean left atrial pressure, aortic diastolic pressure and mean pump rotation speed. The Hemopump was allowed to operate either at a constant speed or at two different speeds during a cardiac cycle. The goal was to maximise the objective function by varying the magnitude and timing of the pump speed. Using a canine circulatory model, it was demonstrated that, in general, different cardiac conditions or different clinical objectives require different operation parameters. For example, when a left ventricle with minor ischaemia was simulated, and the main objective was to increase stoke volume, the objective function was maximised, from a value of 0.877 when the pump was off, to 0.946 when the pump was operated at speed 2 (18 500 revolutions min(-1)). On the other hand, for a severely ischaemic heart, the optimum pump speed became speed 3 (20 000 revolutions min(-1)), which maximized the objective function to 0.943 (from 0.707 when the pump was off). The results also suggest that it is more beneficial to operate the Hemopump at two different speeds during a cardiac cycle (a higher speed during systole and early diastole, and a lower speed during late diastole) than to maintain a constant speed throughout the cardiac cycle.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [21] THE PUCA PUMP - A LEFT-VENTRICULAR ASSIST DEVICE
    VERKERKE, B
    DEMUINCK, ED
    RAKHORST, G
    BLANKSMA, PK
    ARTIFICIAL ORGANS, 1993, 17 (05) : 365 - 368
  • [22] DEVELOPMENT OF AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE
    LIAPIS, CD
    LEVINE, FH
    NUGENT, WC
    KYO, S
    TSAI, CH
    SINGH, PI
    ADAMS, B
    PETSCHEK, H
    AUSTEN, WG
    BUCKLEY, MJ
    SURGICAL FORUM, 1981, 32 : 244 - 246
  • [23] LEFT-VENTRICULAR ASSIST DEVICE SYSTEM CONSIDERATIONS
    MOISE, JC
    BUTLER, KC
    WAMPLER, R
    FUJIMOTO, L
    SMITH, W
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 564 - 564
  • [24] LEFT-VENTRICULAR ASSIST WITH AN AXIAL-FLOW PUMP (HEMOPUMP) - CLINICAL-APPLICATION
    WIEBALCK, AC
    WOUTERS, PF
    WALDENBERGER, FR
    AKPINAR, B
    LAUWERS, PM
    DEMEYERE, RH
    SERGEANT, PT
    DAENEN, WJ
    FLAMENG, WJ
    ANNALS OF THORACIC SURGERY, 1993, 55 (05): : 1141 - 1146
  • [25] Quality of life in long-term survivors of the hemopump left ventricular assist device
    Baldwin, Robert T.
    Radovancevic, Branislav
    Duncan, J.Michael
    Ford, Stuart
    Lonquist, James L.
    Munoz, Eric
    Abou-Awdi, Nancy L.
    Frazier, O.H.
    ASAIO Transactions, 1991, 37 (03):
  • [26] ABDOMINAL LEFT-VENTRICULAR ASSIST DEVICE - PRECLINICAL STUDIES
    ROBINSON, WJ
    DALY, BDT
    HUGHES, DA
    MIGLIORE, JJ
    HIBBS, CW
    IGO, SR
    NORMAN, JC
    ANNALS OF THORACIC SURGERY, 1975, 19 (05): : 540 - 551
  • [27] MAGNETICALLY ACTUATED IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE
    KOVACS, SG
    WEBER, D
    YARNOZ, MD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (08) : 583 - 584
  • [28] EARLY EXPERIENCE WITH THE BIOMEDICUS LEFT-VENTRICULAR ASSIST DEVICE
    RAUDKIVI, PJ
    ROBINSON, MC
    NEW ZEALAND MEDICAL JOURNAL, 1991, 104 (914) : 260 - 260
  • [29] A PERMANENT LEFT-VENTRICULAR ASSIST DEVICE - INVIVO TESTING
    ROSENBERG, G
    SNYDER, AJ
    WEISS, WJ
    CLEARY, TJ
    PIERCE, WS
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 65 - 67
  • [30] EFFECT OF THE HEMOPUMP LEFT-VENTRICULAR ASSIST DEVICE ON REGIONAL MYOCARDIAL PERFUSION AND FUNCTION - REDUCTION OF ISCHEMIA DURING CORONARY-OCCLUSION
    MERHIGE, ME
    SMALLING, RW
    CASSIDY, D
    BARRETT, R
    WISE, G
    SHORT, J
    WAMPLER, RK
    CIRCULATION, 1989, 80 (05) : 158 - 166