Optimum control of the hemopump as a left-ventricular assist device

被引:11
|
作者
He, P [1 ]
Bai, J
Xia, DD
机构
[1] Wright State Univ, Dept Biomed Ind & Human Factors Engn, Dayton, OH 45435 USA
[2] Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
hemopump; ischaemia; left-ventricular assist device; optimum control;
D O I
10.1007/BF02345135
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A general framework for designing an optimum control strategy for the Hemopump is described. An objective function was defined that includes four membership functions, each constructed based on the desired values of one of the four members: stroke volume, mean left atrial pressure, aortic diastolic pressure and mean pump rotation speed. The Hemopump was allowed to operate either at a constant speed or at two different speeds during a cardiac cycle. The goal was to maximise the objective function by varying the magnitude and timing of the pump speed. Using a canine circulatory model, it was demonstrated that, in general, different cardiac conditions or different clinical objectives require different operation parameters. For example, when a left ventricle with minor ischaemia was simulated, and the main objective was to increase stoke volume, the objective function was maximised, from a value of 0.877 when the pump was off, to 0.946 when the pump was operated at speed 2 (18 500 revolutions min(-1)). On the other hand, for a severely ischaemic heart, the optimum pump speed became speed 3 (20 000 revolutions min(-1)), which maximized the objective function to 0.943 (from 0.707 when the pump was off). The results also suggest that it is more beneficial to operate the Hemopump at two different speeds during a cardiac cycle (a higher speed during systole and early diastole, and a lower speed during late diastole) than to maintain a constant speed throughout the cardiac cycle.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [11] The hemopump as left ventricular assist device in postcardiotomy heart failure.
    Meyns, B
    Sergeant, P
    Demeyere, R
    Vandommele, J
    Lauwers, P
    Ferdinande, P
    Verwaest, C
    Daenen, W
    Flameng, W
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 : A38 - A38
  • [12] LEFT-VENTRICULAR ASSIST DEVICE APPROVED
    NIGHTINGALE, SL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (19): : 1488 - 1488
  • [13] THERMOCARDIOSYSTEMS LEFT-VENTRICULAR ASSIST DEVICE
    FRAZIER, OH
    ANNALS OF THORACIC SURGERY, 1992, 54 (05): : 1019 - 1019
  • [14] The Hemopump™, The First Intravascular Ventricular Assist Device
    Wampler, Richard
    Frazier, O. H.
    ASAIO JOURNAL, 2019, 65 (03) : 297 - 300
  • [15] EFFECT OF DRIVE MODE OF LEFT-VENTRICULAR ASSIST DEVICE ON THE LEFT-VENTRICULAR MECHANICS
    NAKAMURA, T
    HAYASHI, K
    SEKI, J
    NAKATANI, T
    NODA, H
    TAKANO, H
    AKUTSU, T
    ARTIFICIAL ORGANS, 1988, 12 (01) : 56 - 66
  • [16] THE PREDICTION OF LEFT-VENTRICULAR OUTPUT FROM LEFT-VENTRICULAR ASSIST DEVICE OUTPUT
    SEKII, H
    TAKANO, H
    TAENAKA, Y
    TAKATANI, S
    NODA, H
    KINOSHITA, M
    TATSUMI, E
    YAGURA, A
    AKUTSU, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1988, 52 (08): : 849 - 850
  • [17] The Hemopump as a left ventricular assist device in pediatric applications: Initial Canadian applications
    AlJarallah, AS
    Duncan, WJ
    Broecker, L
    Allen, L
    Cornel, G
    CANADIAN JOURNAL OF CARDIOLOGY, 1997, 13 (05) : 489 - 494
  • [18] EFFECTS OF LEFT-VENTRICULAR ASSIST DEVICE ON HEMATOLOGY
    MORI, Y
    KAWASE, S
    NAGAOKA, S
    KIKUCHI, T
    KUSAKABE, M
    YOKOYAMA, Y
    OKAWA, Y
    ITO, K
    ARTIFICIAL ORGANS, 1981, 5 (03) : 314 - 314
  • [19] DEVELOPMENT OF A PIEZOELECTRIC LEFT-VENTRICULAR ASSIST DEVICE
    ONEILL, CG
    SMILEY, PC
    SMART, DL
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1975, 11 (05) : 963 - 964
  • [20] ETHICAL CONSIDERATIONS OF LEFT-VENTRICULAR ASSIST DEVICE
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 235 (08): : 823 - 824