Three-Dimensional Ultrasound Molecular Imaging of Angiogenesis in Colon Cancer Using a Clinical Matrix Array Ultrasound Transducer

被引:46
|
作者
Wang, Huaijun [1 ]
Kaneko, Osamu F. [1 ]
Tian, Lu [2 ]
Hristov, Dimitre [3 ]
Willmann, Juergen K. [1 ]
机构
[1] Stanford Univ, Sch Med, Mol Imaging Program Stanford, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Hlth Res & Policy, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
ultrasound; molecular imaging; 3-dimensional; cancer; angiogenesis; METASTATIC COLORECTAL-CANCER; ENDOTHELIAL GROWTH-FACTOR; CONTRAST-ENHANCED ULTRASOUND; TUMOR HETEROGENEITY; BREAST-CANCER; TARGETED MICROBUBBLES; RESPONSE EVALUATION; THERAPY; BEVACIZUMAB; AGENTS;
D O I
10.1097/RLI.0000000000000128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We sought to assess the feasibility and reproducibility of 3-dimensional ultrasound molecular imaging (USMI) of vascular endothelial growth factor receptor 2 (VEGFR2) expression in tumor angiogenesis using a clinical matrix array transducer and a clinical grade VEGFR2-targeted contrast agent in a murine model of human colon cancer. Materials and Methods: Animal studies were approved by the Institutional Administrative Panel on Laboratory Animal Care. Mice with human colon cancer xenografts (n = 33) were imaged with a clinical ultrasound system and transducer (Philips iU22; X6-1) after intravenous injection of either clinical grade VEGFR2-targeted microbubbles or nontargeted control microbubbles. Nineteen mice were scanned twice to assess imaging reproducibility. Fourteen mice were scanned both before and 24 hours after treatment with either bevacizumab (n = 7) or saline only (n = 7). Three-dimensional USMI data sets were retrospectively reconstructed into multiple consecutive 1-mm-thick USMI data sets to simulate 2-dimensional imaging. Vascular VEGFR2 expression was assessed ex vivo using immunofluorescence. Results: Three-dimensional USMI was highly reproducible using both VEGFR2-targeted microbubbles and nontargeted control microbubbles (intraclass correlation coefficient, 0.83). The VEGFR2-targeted USMI signal significantly (P = 0.02) decreased by 57% after antiangiogenic treatment compared with the control group, which correlated well with ex vivo VEGFR2 expression on immunofluorescence (rho = 0.93, P = 0.003). If only central 1-mm tumor planes were analyzed to assess antiangiogenic treatment response, the USMI signal change was significantly (P = 0.006) overestimated by an average of 27% (range, 2%-73%) compared with 3-dimensional USMI. Conclusions: Three-dimensional USMI is feasible and highly reproducible and allows accurate assessment and monitoring of VEGFR2 expression in tumor angiogenesis in a murine model of human colon cancer.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 50 条
  • [21] Three-dimensional ultrasound imaging of the eye
    Downey, DB
    Nicolle, DA
    Levin, MF
    Fenster, A
    EYE, 1996, 10 : 75 - 81
  • [22] Three-dimensional ultrasound imaging of the prostate
    Tong, SD
    Cardinal, HN
    Downey, DB
    Fenster, A
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 113 - 123
  • [23] Three-dimensional ultrasound imaging of the prostate
    Fenster, A
    Downey, DB
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 2 - 11
  • [24] Three-dimensional ultrasound imaging of the vasculature
    Fenster, A
    Lee, D
    Sherebrin, S
    Rankin, R
    Downey, D
    ULTRASONICS, 1998, 36 (1-5) : 629 - 633
  • [25] Three-dimensional printable ultrasound transducer stabilization system
    Derrick, Donald
    Carignan, Christopher
    Chen, Wei-rong
    Shujau, Muawiyath
    Best, Catherine T.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 144 (05): : EL392 - EL398
  • [26] Diagnosis of cervical cancer by ultrasound graduates using intelligent three-dimensional imaging
    Wang, Wei
    Li, Tongbin
    Gao, Juan
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2022, 43 (05) : 122 - 123
  • [27] Sources and impact of artifacts on clinical three-dimensional ultrasound imaging
    Nelson, TR
    Pretorius, DH
    Hull, A
    Riccabona, M
    Sklansky, MS
    James, G
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (04) : 374 - 383
  • [28] An Axial Array for Three-Dimensional Intravascular Ultrasound
    Alles, Erwin J.
    van Dijk, Gerrit J.
    van der Steen, Antonius F. W.
    Gisolf, Andries
    van Dongen, Koen W. A.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1153 - 1156
  • [29] Correlation analysis of three-dimensional strain imaging using ultrasound two-dimensional array transducers
    Rao, Min
    Varghese, Tomy
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 124 (03): : 1858 - 1865
  • [30] Three-dimensional ultrasound imaging in air using a 2d array on a fixed platform
    Moebus, Marco
    Zoubir, Abdelhak M.
    2007 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL II, PTS 1-3, 2007, : 961 - +