Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty

被引:47
|
作者
Laurer, Helmut L. [1 ]
Wutzler, Sebastian [1 ]
Possner, Susann [1 ]
Geiger, Emanuel V. [1 ]
El Saman, Andre [1 ]
Marzi, Ingo [1 ]
Frank, Johannes [1 ]
机构
[1] JW Goethe Univ Hosp, Dept Trauma Hand & Reconstruct Surg, D-60590 Frankfurt, Germany
关键词
Periprosthetic femoral fracture; Vancouver classification; Revision arthroplasty; Hip replacement; Complications; COMPRESSION PLATE FIXATION; HIP-ARTHROPLASTY; FEMUR; CLASSIFICATION; REPLACEMENT; IMPLANT;
D O I
10.1007/s00402-011-1272-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The rate of periprosthetic femoral fractures after hip arthroplasty is rising and the estimated current lifetime incidence is 0.4-2.1%. While most authors recommend revision arthroplasty in patients with loose femoral shaft components, treatment options for patients with stable stem are not fully elucidated. Against this background we performed a retrospective chart analysis with clinical follow-up examination of 32 cases that sustained a Vancouver type B1 or C periprosthetic fracture (stable stem). Overall 16 cases were treated by open reduction and internal fixation (ORIF) by plate osteosynthesis and 16 cases by revision arthroplasty (RA). Both groups were comparable regarding age, gender, follow-up time interval, time interval from primary hip arthroplasty to fracture and rate of cemented femoral components, but more type C fractures were treated by ORIF. Functional outcome expressed by the median timed "Up and Go" test did not differ significantly (30 s ORIF vs. 24 s RA, P = 0.19). However, by comparable systemic complications surgery-related complications were significantly more frequent in plate osteosynthesis (ORIF n = 10 vs. RA n = 3, P = 0.03). Based on our results, further studies, preferable via a multicenter approach, should focus on identifying patients that benefit from ORIF in periprosthetic fractures. A misinterpretation of type B2 fractures with loose implant as type B1 fractures may cause implant failure in case of ORIF. The use of angular stable implants, additional cable wires or bone enhancing means is recommended.
引用
收藏
页码:983 / 989
页数:7
相关论文
共 50 条
  • [41] Author Reply: Cement-In-Cement Revision for Selected Vancouver Type B1 Femoral Periprosthetic Fractures: A Biomechanical Analysis
    Crawford, Ross W.
    Whitehouse, Sarah L.
    Brew, Chris J.
    Wilson, Lance J.
    Hubble, Matt J. W.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 1446 - 1447
  • [42] Outcomes After Operative Fixation of Vancouver B2 and B3 Type Periprosthetic Fractures
    Barghi, Ameen
    Hanna, Philip
    Merchan, Nelson
    Lechtig, Aron
    Haggerty, Christopher
    Weaver, Michael J.
    von Keudell, Arvind
    Wixted, John
    Appleton, Paul
    Rodriguez, Edward
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2022, 36 (05) : 228 - 233
  • [43] Three dimensional finite-element analysis of treating Vancouver B1 periprosthetic femoral fractures with three kinds of internal fixation
    Wang, Guowei
    Wang, Dong
    Mao, Junsheng
    Lin, Yongjie
    Yin, Zudong
    Wang, Bingchen
    He, Yu
    Sun, Shui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (04): : 7557 - 7564
  • [44] Three dimensional finite-element analysis of treating Vancouver B1 periprosthetic femoral fractures with three kinds of internal fixation
    Wang, Guowei
    Wang, Dong
    Mao, Junsheng
    Lin, Yongjie
    Yin, Zudong
    Wang, Bingchen
    He, Yu
    Sun, Shui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 10915 - 10922
  • [45] Radiologic outcomes of open reduction and internal fixation for cementless stems in Vancouver B2 periprosthetic fractures
    Park, Jong-Seok
    Hong, Sijohn
    Nho, Jae-Hwi
    Kang, Deokwon
    Choi, Hyung-Suk
    Suh, You-Sung
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2019, 53 (01) : 24 - 29
  • [46] Operative Versorgungsstrategien bei periprothetischen Femurfrakturen Typ Vancouver BSurgical treatment strategies for periprosthetic femoral fractures of type Vancouver B
    Christian Ries
    Patrick Gerhardt
    Peter Helwig
    Holger Bäthis
    Stephan Kirschner
    Tim Rolvien
    Frank Timo Beil
    Die Orthopädie, 2025, 54 (3) : 205 - 217
  • [47] Open reduction and internal fixation (ORIF) versus stem revision (SR) in Vancouver B2 periprosthetic hip fractures: a monocentric, 10-year retrospective study
    Dascal, Adrian
    Steinmetz, Sylvain
    Moerenhout, Kevin
    Cherix, Stephane
    SWISS MEDICAL WEEKLY, 2023, 153 : 54S - 54S
  • [48] Delayed treatment of femoral neck fractures in 58 children: open reduction internal fixation versus closed reduction internal fixation
    Ju, Li
    Jiang, Bo
    Lou, Yue
    Zheng, Pengfei
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2016, 25 (05): : 459 - 465
  • [49] Periprosthetic fracture fixation in Vancouver B1 femoral shaft fractures: A biomechanical study comparing two plate systems
    Waehnert, Dirk
    Mueller, Marcus
    Tiedemann, Hendrik
    Maerdian, Sven
    Raschke, Michael J.
    Koesters, Clemens
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 24 : 150 - 154
  • [50] Periprosthetic Femoral Fracture - A Biomechanical Comparison Between Vancouver Type B1 and B2 Fixation Methods
    Moazen, Mehran
    Mak, Jonathan H.
    Etchels, Lee W.
    Jin, Zhongmin
    Wilcox, Ruth K.
    Jones, Alison C.
    Tsiridis, Eleftherios
    JOURNAL OF ARTHROPLASTY, 2014, 29 (03): : 495 - 500