Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty

被引:47
|
作者
Laurer, Helmut L. [1 ]
Wutzler, Sebastian [1 ]
Possner, Susann [1 ]
Geiger, Emanuel V. [1 ]
El Saman, Andre [1 ]
Marzi, Ingo [1 ]
Frank, Johannes [1 ]
机构
[1] JW Goethe Univ Hosp, Dept Trauma Hand & Reconstruct Surg, D-60590 Frankfurt, Germany
关键词
Periprosthetic femoral fracture; Vancouver classification; Revision arthroplasty; Hip replacement; Complications; COMPRESSION PLATE FIXATION; HIP-ARTHROPLASTY; FEMUR; CLASSIFICATION; REPLACEMENT; IMPLANT;
D O I
10.1007/s00402-011-1272-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The rate of periprosthetic femoral fractures after hip arthroplasty is rising and the estimated current lifetime incidence is 0.4-2.1%. While most authors recommend revision arthroplasty in patients with loose femoral shaft components, treatment options for patients with stable stem are not fully elucidated. Against this background we performed a retrospective chart analysis with clinical follow-up examination of 32 cases that sustained a Vancouver type B1 or C periprosthetic fracture (stable stem). Overall 16 cases were treated by open reduction and internal fixation (ORIF) by plate osteosynthesis and 16 cases by revision arthroplasty (RA). Both groups were comparable regarding age, gender, follow-up time interval, time interval from primary hip arthroplasty to fracture and rate of cemented femoral components, but more type C fractures were treated by ORIF. Functional outcome expressed by the median timed "Up and Go" test did not differ significantly (30 s ORIF vs. 24 s RA, P = 0.19). However, by comparable systemic complications surgery-related complications were significantly more frequent in plate osteosynthesis (ORIF n = 10 vs. RA n = 3, P = 0.03). Based on our results, further studies, preferable via a multicenter approach, should focus on identifying patients that benefit from ORIF in periprosthetic fractures. A misinterpretation of type B2 fractures with loose implant as type B1 fractures may cause implant failure in case of ORIF. The use of angular stable implants, additional cable wires or bone enhancing means is recommended.
引用
收藏
页码:983 / 989
页数:7
相关论文
共 50 条
  • [31] Locking compression plate versus revision-prosthesis for Vancouver type B2 periprosthetic femoral fractures after total hip arthroplasty
    Joestl, Julian
    Hofbauer, Marcus
    Lang, Nikolaus
    Tiefenboeck, Thomas
    Hajdu, Stefan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (04): : 939 - 943
  • [32] Outcome after treatment of Vancouver B2 peri-prosthetic femoral fractures: revision arthroplasty and compression cerclage system fixation
    Shi, Dong-Quan
    Xu, Zhi-Hong
    Xu, Xing-Quan
    Chen, Dong-Yang
    Yuan, Tao
    Weng, Wen-Jie
    Xiong, Jin
    Jiang, Qing
    ANNALS OF JOINT, 2016, 1
  • [33] Locking compression plate fixation of Vancouver type-b1 periprosthetic femoral fractures
    Buttaro, M. A.
    Farfalli, G.
    Nunez, M. Paredes
    Comba, F.
    Piccaluga, F.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09): : 1964 - 1969
  • [34] Revision hip arthroplasty as a treatment of Vancouver B3 periprosthetic femoral fractures without bone grafting
    Wang, Jia-Qi
    Gao, You-Shui
    Mei, Jiong
    Rao, Zhi-Tao
    Wang, Shu-Qing
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (05) : 449 - 453
  • [35] Revision hip arthroplasty as a treatment of Vancouver B3 periprosthetic femoral fractures without bone grafting
    Jia-Qi Wang
    You-Shui Gao
    Jiong Mei
    Zhi-Tao Rao
    Shu-Qing Wang
    Indian Journal of Orthopaedics, 2013, 47 : 449 - 453
  • [36] Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases
    Graham, Simon M.
    Moazen, Mehran
    Leonidou, Andreas
    Tsiridis, Eleftherios
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (03) : 426 - 436
  • [37] Analysis of complications in 97 periprosthetic Vancouver B2 fractures treated either by internal fixation or revision arthroplasty
    Eckardt, H.
    Windischbauer, D.
    Morgenstern, M.
    Stoffel, K.
    Clauss, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (04) : 1647 - 1653
  • [38] Analysis of complications in 97 periprosthetic Vancouver B2 fractures treated either by internal fixation or revision arthroplasty
    H. Eckardt
    D. Windischbauer
    M. Morgenstern
    K. Stoffel
    M. Clauss
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1647 - 1653
  • [39] The impact of stem fixation method on Vancouver Type B1 periprosthetic femoral fracture management
    Wang, Katherine
    Kenanidis, Eustathios
    Gamie, Zakareya
    Suleman, Khurram
    Miodownik, Mark
    Avadi, Mahsa
    Horne, David
    Thompson, Jonathan
    Tsiridis, Eleftherios
    Moazen, Mehran
    SICOT-J, 2022, 8
  • [40] Comment on article "Cement-in-Cement Revision for Selected Vancouver Type B1 Femoral Periprosthetic Fractures: A Biomechanical Analysis"
    Melvin, Stuart
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 1446 - 1446