The impact of peak saturation of the arterial input function on quantitative evaluation of dynamic susceptibility contrast-enhanced MR studies

被引:60
|
作者
Ellinger, R
Kremser, C
Schocke, MFH
Kolbitsch, C
Griebel, J
Felber, SR
Aichner, FT
机构
[1] Univ Innsbruck, Dept Magnet Resonance, A-6020 Innsbruck, Austria
[2] Univ Innsbruck, Dept Anesthesia & Intens Care Med, A-6020 Innsbruck, Austria
[3] GSF, Natl Res Ctr Environm & Hlth, Inst Radiobiol, Neuherberg, Germany
关键词
arterial input function; magnetic resonance imaging;
D O I
10.1097/00004728-200011000-00022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work was to investigate systematic errors in dynamic contrast-enhanced MR perfusion studies due to peak saturation of the arterial input function (AIF) and to introduce a simple correction algorithm. Method: Computer simulations were performed to evaluate the influence of AIF peak saturation and to demonstrate the effectiveness of the presented correction algorithm. To compare the computer simulations with real MR data, MR perfusion measurements were performed on volunteers. Results: The computer simulations show that AIF peak saturation leads to a systematic overestimation of cerebral blood volume (CBV) and cerebral blood flow (CBF) values, which was confirmed by comparing the obtained MR data with PET results. With use of an improved calculation algorithm correcting for AIF peak saturation, a significant improvement of the obtained CBV and CBF values could be demonstrated. Conclusion: Our results suggest that AIF peak saturation leads to a significant systematic error in the determination of CBV and CBF values and has necessarily to he taken into account for dynamic contrast-enhanced MR perfusion studies.
引用
收藏
页码:942 / 948
页数:7
相关论文
共 50 条
  • [31] Pulmonary perfusion: Evaluation with dynamic contrast-enhanced MR imaging
    Hatabu, H
    Tadamura, E
    Kim, D
    Li, W
    Prasad, PV
    Edelman, RR
    RADIOLOGY, 1996, 201 : 407 - 407
  • [32] Quantitative parametric analysis of contrast-enhanced lesions in dynamic MR mammography
    Hauth, E. A. M.
    Jaeger, H.
    Maderwald, S.
    Muehler, A.
    Kimmig, R.
    Forsting, M.
    RADIOLOGE, 2008, 48 (06): : 593 - 600
  • [33] Quantitative evaluation of free-form deformation registration for dynamic contrast-enhanced MR mammography
    Tanner, Christine
    Schnabel, Julia A.
    Hill, Derek L. G.
    Hawkes, David J.
    Degenhard, Andreas
    Leach, Martin O.
    Hose, D. Rodney
    Hall-Craggs, Margaret A.
    Usiskin, Sasha I.
    MEDICAL PHYSICS, 2007, 34 (04) : 1221 - 1233
  • [34] Evaluation of signal formation in local arterial input function measurements of dynamic susceptibility contrast MRI
    Bleeker, Egbert J. W.
    Webb, Andrew G.
    van Walderveen, Marianne A. A.
    van Buchem, Mark A.
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1324 - 1331
  • [35] Estimating the arterial input function using two reference tissues in dynamic contrast-enhanced MRI studies: Fundamental concepts and simulations
    Yang, C
    Karczmar, GS
    Medved, M
    Stadler, WM
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1110 - 1117
  • [36] Reproducibility and Optimal Arterial Input Function Selection in Dynamic Contrast-Enhanced Perfusion MRI in the Healthy Brain
    Cramer, Stig P.
    Larsson, Henrik B. W.
    Knudsen, Maria H.
    Simonsen, Helle J.
    Vestergaard, Mark B.
    Lindberg, Ulrich
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1229 - 1240
  • [37] Brain Gliomas: Multicenter Standardized Assessment of Dynamic Contrast-enhanced and Dynamic Susceptibility Contrast MR Images
    Anzalone, Nicoletta
    Castellano, Antonella
    Cadioli, Marcello
    Conte, Gian Marco
    Cuccarini, Valeria
    Bizzi, Alberto
    Grimaldi, Marco
    Costa, Antonella
    Grillea, Giovanni
    Vitali, Paolo
    Aquino, Domenico
    Terreni, Maria Rosa
    Torri, Valter
    Erickson, Bradley J.
    Caulo, Massimo
    RADIOLOGY, 2018, 287 (03) : 933 - 943
  • [38] Arterial input function calculation in dynamic contrast-enhanced MRI: an in vivo validation study using co-registered contrast-enhanced ultrasound imaging
    Hatef Mehrabian
    Chaitanya Chandrana
    Ian Pang
    Rajiv Chopra
    Anne L. Martel
    European Radiology, 2012, 22 : 1735 - 1747
  • [39] Editorial for "Influence of Different Measurement Methods of Arterial Input Function on Quantitative Dynamic Contrast-Enhanced MRI Parameters in Head and Neck Cancer"
    Anzai, Yoshimi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (01) : 133 - 134
  • [40] Arterial input function calculation in dynamic contrast-enhanced MRI: an in vivo validation study using co-registered contrast-enhanced ultrasound imaging
    Mehrabian, Hatef
    Chandrana, Chaitanya
    Pang, Ian
    Chopra, Rajiv
    Martel, Anne L.
    EUROPEAN RADIOLOGY, 2012, 22 (08) : 1735 - 1747