The impact of peak saturation of the arterial input function on quantitative evaluation of dynamic susceptibility contrast-enhanced MR studies

被引:60
|
作者
Ellinger, R
Kremser, C
Schocke, MFH
Kolbitsch, C
Griebel, J
Felber, SR
Aichner, FT
机构
[1] Univ Innsbruck, Dept Magnet Resonance, A-6020 Innsbruck, Austria
[2] Univ Innsbruck, Dept Anesthesia & Intens Care Med, A-6020 Innsbruck, Austria
[3] GSF, Natl Res Ctr Environm & Hlth, Inst Radiobiol, Neuherberg, Germany
关键词
arterial input function; magnetic resonance imaging;
D O I
10.1097/00004728-200011000-00022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work was to investigate systematic errors in dynamic contrast-enhanced MR perfusion studies due to peak saturation of the arterial input function (AIF) and to introduce a simple correction algorithm. Method: Computer simulations were performed to evaluate the influence of AIF peak saturation and to demonstrate the effectiveness of the presented correction algorithm. To compare the computer simulations with real MR data, MR perfusion measurements were performed on volunteers. Results: The computer simulations show that AIF peak saturation leads to a systematic overestimation of cerebral blood volume (CBV) and cerebral blood flow (CBF) values, which was confirmed by comparing the obtained MR data with PET results. With use of an improved calculation algorithm correcting for AIF peak saturation, a significant improvement of the obtained CBV and CBF values could be demonstrated. Conclusion: Our results suggest that AIF peak saturation leads to a significant systematic error in the determination of CBV and CBF values and has necessarily to he taken into account for dynamic contrast-enhanced MR perfusion studies.
引用
收藏
页码:942 / 948
页数:7
相关论文
共 50 条
  • [21] Blind Multi-Channel Estimation of Arterial Input Function in Dynamic Contrast-Enhanced MRI
    Jirik, R.
    Bartos, M.
    Standara, M.
    Taxt, T.
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2010, : 373 - 377
  • [22] Effects of arterial input function selection on kinetic parameters in brain dynamic contrast-enhanced MRI
    Keil, Vera C.
    Maedler, Burkhard
    Gieseke, Juergen
    Fimmers, Rolf
    Hattingen, Elke
    Schild, Hans H.
    Hadizadeh, Dariusch R.
    MAGNETIC RESONANCE IMAGING, 2017, 40 : 83 - 90
  • [23] Arterial input function estimation compensating for inflow and partial voluming in dynamic contrast-enhanced MRI
    Tseng, Chih-Hsien
    Nagtegaal, Martijn A.
    van Osch, Matthias J. P.
    Jaspers, Jaap
    Romero, Alejandra Mendez
    Wielopolski, Piotr
    Smits, Marion
    Vos, Frans M.
    NMR IN BIOMEDICINE, 2024,
  • [24] Influence of Different Measurement Methods of Arterial Input Function on Quantitative Dynamic Contrast-Enhanced MRI Parameters in Head and Neck Cancer
    Dong, Wanxin
    Volk, Andreas
    Djaroum, Meriem
    Girot, Charly
    Balleyguier, Corinne
    Lebon, Vincent
    Garcia, Gabriel
    Ammari, Samy
    Temam, Stephane
    Gorphe, Philippe
    Wei, Lecong
    Pitre-Champagnat, Stephanie
    Lassau, Nathalie
    Bidault, Francois
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (01) : 122 - 132
  • [25] Assessment of cerebrovascular reactivity by dynamic susceptibility contrast-enhanced MR imaging
    Nighoghossian, N
    Berthezene, Y
    Meyer, R
    Cinotti, L
    Adeleine, P
    Philippon, B
    Froment, JC
    Trouillas, P
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 1997, 149 (02) : 171 - 176
  • [26] Evaluation of an AIF correction algorithm for dynamic susceptibility contrast-enhanced perfusion MR1
    Brunecker, Peter
    Endres, Matthias
    Nolte, Christian H.
    Schultze, Joerg
    Wegener, Susanne
    Jungehuelsing, Gerhard Jan
    Mueller, Bianca
    Kerskens, Christian M.
    Fiebach, Jochen B.
    Villringer, Arno
    Steinbrink, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 102 - 110
  • [27] Use of Cardiac Output to Improve Measurement of Input Function in Quantitative Dynamic Contrast-Enhanced MRI
    Zhang, Jeff L.
    Rusinek, Henry
    Bokacheva, Louisa
    Chen, Qun
    Storey, Pippa
    Lee, Vivian S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 656 - 665
  • [28] Assessment of Renal Function with Dynamic Contrast-Enhanced MR Imaging
    Bokacheva, Louisa
    Rusinek, Henry
    Zhang, Jeff L.
    Lee, Vivian S.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (04) : 597 - +
  • [29] Phantom validation of quantitative susceptibility and dynamic contrast-enhanced permeability MR sequences across instruments and sites
    Hobson, Nicholas
    Polster, Sean P.
    Cao, Ying
    Flemming, Kelly
    Shu, Yunhong
    Huston, John
    Gerrard, Chandra Y.
    Selwyn, Reed
    Mabray, Marc
    Zafar, Atif
    Girard, Romuald
    Carrion-Penagos, Julian
    Chen, Yu Fen
    Parrish, Todd
    Zhou, Xiaohong Joe
    Koenig, James, I
    Shenkar, Robert
    Stadnik, Agnieszka
    Koskimaki, Janne
    Dimov, Alexey
    Turley, Dallas
    Carroll, Timothy
    Awad, Issam A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (04) : 1192 - 1199
  • [30] Celiac Disease: Evaluation with Dynamic Contrast-enhanced MR Imaging
    Masselli, Gabriele
    Picarelli, Antonio
    Di Tola, Marco
    Libanori, Valerio
    Donato, Giuseppe
    Polettini, Elisabetta
    Piermattei, Alessandra
    Palumbo, Piergaspare
    Pittalis, Angelo
    Saponara, Annarita
    Gualdi, Gianfranco
    RADIOLOGY, 2010, 256 (03) : 783 - 790