Avalanche effect in Si heavily irradiated detectors: Physical model and perspectives for application

被引:18
|
作者
Eremin, V. [1 ]
Verbitskaya, E. [1 ]
Zabrodskii, A. [1 ]
Li, Z. [2 ]
Haerkoenen, J. [3 ]
机构
[1] Ioffe Phys Tech Inst RAS, St Petersburg, Russia
[2] Brookhaven Natl Lab, Upton, NY 11973 USA
[3] CERN PH, Helsinki Inst Phys, Geneva, Switzerland
关键词
Silicon detector; Electric field distribution; Charge collection; Radiation hardness; ELECTRIC-FIELD DISTRIBUTION; SILICON DETECTORS; RADIATION HARDNESS;
D O I
10.1016/j.nima.2011.05.002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The model explaining an enhanced collected charge in detectors irradiated to 10(15)-10(16) n(eq)/cm(2) is developed. This effect was first revealed in heavily irradiated n-on-p detectors operated at high bias voltage ranging from 900 to 1700 V. The model is based on the fundamental effect of carrier avalanche multiplication in the space charge region and in our case is extended with a consideration of p-n junctions with a high concentration of the deep levels. It is shown that the efficient trapping of free carriers from the bulk generation current to the deep levels of radiation induced defects leads to the stabilization of the irradiated detector operation in avalanche multiplication mode due to the reduction of the electric field at the junction. The charge collection efficiency and the detector reverse current dependences on the applied bias have been numerically simulated in this study and they well correlate to the recent experimental results of CERN RD50 collaboration. The developed model of enhanced collected charge predicts a controllable operation of heavily irradiated detectors that is promising for the detector application in the upcoming experiments in a high luminosity collider. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 37 条
  • [1] Test results of heavily irradiated Si detectors
    Albergo, S
    Azzi, P
    Babucci, E
    Bacchetta, N
    Bader, A
    Bagliesi, G
    Bartalini, P
    Basti, A
    Biggeri, U
    Bilei, GM
    Bisello, D
    Boemi, D
    Bosi, F
    Borrello, L
    Bozzi, C
    Breuker, H
    Bruzzi, M
    Candelori, A
    Caner, A
    Castaldi, R
    Castro, A
    Catacchini, E
    Checcucci, B
    Ciampolini, P
    Civinini, C
    Connotte, J
    Creanza, D
    D'Alessandro, R
    Da Rold, M
    de Palma, M
    Dell'Orso, R
    Della Marina, R
    Eklund, D
    Elliot-Peisert, A
    Feld, L
    Fiore, L
    Focardi, E
    French, M
    Freudenreich, K
    Giassi, A
    Giraldo, A
    Glessing, B
    Gu, WH
    Hall, G
    Hammerstrom, R
    Hrubec, J
    Huhtinen, M
    Karimaki, V
    Krammer, M
    Lariccia, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 238 - 241
  • [2] Operational voltage of silicon heavily irradiated strip detectors utilizing avalanche multiplication effect
    Verbitskaya, E.
    Eremin, V.
    Zabrodskii, A.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [3] Restriction on the gain in collected charge due to carrier avalanche multiplication in heavily irradiated Si strip detectors
    Verbitskaya, E.
    Eremin, V.
    Zabrodskii, A.
    Li, Z.
    Luukka, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 730 : 66 - 72
  • [4] Gain recovery in heavily Irradiated Low Gain Avalanche Detectors by high temperature annealing
    Mandic, I.
    Cindro, V.
    Gorisek, A.
    Hiti, B.
    Howard, A.
    Kljun, Z.
    Kramberger, G.
    Krzmanc, M. Macek
    Mikuz, M.
    Novak, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1055
  • [5] A comparative study of heavily irradiated silicon and non irradiated SI LEC GaAs detectors
    Biggeri, U
    Borchi, E
    Bruzzi, M
    Eremin, V
    Leroy, C
    Li, Z
    Menichelli, D
    Pirollo, S
    Sciortino, S
    Verbitskaya, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 597 - 601
  • [6] A comparative study of heavily irradiated silicon and non irradiated SI LEC GaAs detectors
    Biggeri, U
    Borchi, E
    Bruzzi, M
    Eremin, V
    Leroy, C
    Li, Z
    Menichelli, D
    Pirollo, S
    Sciortino, S
    Verbitskaya, E
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 114 - 118
  • [7] Comparative study of heavily irradiated silicon and non irradiated SI LEC GaAs detectors
    Biggeri, U.
    Borchi, E.
    Bruzzi, M.
    Eremin, V.
    Leroy, C.
    Li, Z.
    Menichelli, D.
    Pirollo, S.
    Sciortino, S.
    Verbitskaya, E.
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 1): : 597 - 601
  • [8] A two-level model for heavily irradiated silicon detectors
    Borchi, E
    Bruzzi, M
    Li, Z
    Pirollo, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 425 (1-2): : 343 - 346
  • [9] Impact of generation current on the evaluation of the depletion width in heavily irradiated Si detectors
    Gaubas, E.
    Ceponis, T.
    Vaitkus, J.
    JOURNAL OF APPLIED PHYSICS, 2011, 110 (03)
  • [10] Test beam results of heavily irradiated magnetic Czochralski silicon (MCz-Si) strip detectors
    Luukka, P.
    Harkonen, J.
    Maenpaa, T.
    Betchart, B.
    Bhattacharya, S.
    Czellar, S.
    Demina, R.
    Dierlamm, A.
    Gotra, Y.
    Frey, M.
    Hartmann, F.
    Karimaki, V.
    Keutgen, T.
    Korjenevski, S.
    Kortelainen, M. J.
    Lampen, T.
    Lemaitre, V.
    Maksimow, M.
    Militaru, O.
    Moilanen, H.
    Neuland, M.
    Simonis, H. J.
    Spiegel, L.
    Tuominen, E.
    Tuominiemi, J.
    Tuovinen, E.
    Viljanen, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 612 (03): : 497 - 500