Preparation of highly purified monomeric human serum albumin as secondary reference material for standardization of urinary albumin immunoassays

被引:8
|
作者
Itoh, Yoshihisa [1 ]
Ichihara, Kiyoshi [2 ]
Kishi, Kouji [3 ]
Hosogaya, Shigemi [4 ]
Yamada, Toshiyuki [5 ]
机构
[1] Asahikawa Med Univ, Dept Lab Med, Asahikawa, Hokkaido, Japan
[2] Yamaguchi Univ, Dept Lab Sci, Grad Sch Med, Ube, Yamaguchi 755, Japan
[3] Sysmex Corp, Diagnost Reagent Dev, Kobe, Hyogo, Japan
[4] Kagawa Prefectural Coll Hlth Sci, Dept Med Technol, Takamatsu, Kagawa, Japan
[5] Jichi Med Univ, Shimotsuke, Japan
关键词
Albumin; Urine; Reference material; Reference measurement system; ERM-DA470; PROTEINS; MICROALBUMINURIA; CHROMATOGRAPHY; PREVALENCE; ASSIGNMENT; CRM-470; PLASMA; ASSAYS; RISK;
D O I
10.1016/j.cca.2011.09.016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: International external quality assessments have shown variation in results of urinary albumin among various immunoassays. A well-defined candidate reference material for urine albumin (cRM-UA) was prepared to improve standardization. Methods: cRM-UA was prepared from a commercially available preparation of human serum albumin by using gel-filtration HPLC. The value was assigned by transfer from ERM-DA470 using immunoassay systems qualified based on the linearity and variability observed in dilution tests of pooled urine and the calibrators. Effectiveness of recalibration using the cRM-UA was evaluated by measuring 129 urine specimens. Results: The cRM-UA had a monomeric albumin peak which accounted for 98.9% of the total area by gel filtration HPLC. The lyophilized preparation of the cRM-UA had suitable homogeneity, and short- and long-term stability. Nine of 14 immunoassays met the criteria were used for value assignment. The assigned concentration was 225.1 +/- 9.11 mg/l [mean +/- U: expanded uncertainty with k = 2] when reconstituted with 3.00 ml of purified water on weight basis. Recalibration of 7 qualified immunoassays using the cRM-UA resulted in between-method CV of 6.6%. Conclusions: The cRM-UA was successful in achieving standardization of urine albumin results among 7 immunoassays which possess performance attributes representing uniform reactivity to both cRM-UA and clinical urine samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 50 条
  • [21] Optimization of the preparation process for human serum albumin (HSA) nanoparticles
    Langer, K
    Balthasar, S
    Vogel, V
    Dinauer, N
    von Briesen, H
    Schubert, D
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2003, 257 (1-2) : 169 - 180
  • [22] METHYLATION OF OVALBUMIN AND HUMAN SERUM ALBUMIN BY A PURIFIED ENZYME FROM CALF SPLEEN
    LISS, M
    MAXAM, AM
    BIOCHIMICA ET BIOPHYSICA ACTA, 1967, 140 (03) : 555 - &
  • [23] Development of a certified reference material of human serum albumin: certification and value assignment via amino acid analyses
    Kinumi, Tomoya
    Sakaguchi, Yohei
    Takatsu, Akiko
    ANALYTICAL METHODS, 2017, 9 (31) : 4574 - 4580
  • [24] Standardization of immunoassays for measurement of myoglobin in serum. Phase 1: Evaluation of candidate secondary reference materials
    Panteghini, M
    Linsinger, T
    Wu, AHB
    Dati, F
    Apple, FS
    Christenson, RH
    Mair, J
    Schimmel, H
    CLINICA CHIMICA ACTA, 2004, 341 (1-2) : 65 - 72
  • [25] USE OF CARBON ADSORBENTS TO PREPARE HIGHLY POTENT SERUM-ALBUMIN PREPARATION
    METALNIKOVA, NP
    PONOMAREV, VL
    KHANYUCHENKO, SI
    AKIMOV, VN
    MARKOVICH, MN
    KHIMIKO-FARMATSEVTICHESKII ZHURNAL, 1988, 22 (12): : 1482 - 1485
  • [26] Facile biotic/abiotic sandwich detection system for the highly sensitive detection of human serum albumin and glycated albumin
    Sunayama, Hirobumi
    Cheubong, Chehasan
    Takano, Eri
    Takeuchi, Toshifumi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (30) : 7337 - 7345
  • [27] Development of a glucose reference material in human serum for clinical assay standardization
    Wang, Zhichao
    Du, Yuanyuan
    Zhang, Qiaoxuan
    Yan, Jun
    Zhan, Min
    Zhang, Pengwei
    Wan, Zemin
    Wang, Jianbing
    Huang, Xianzhang
    Han, Liqiao
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 228
  • [28] STANDARD REFERENCE MATERIAL (SRM) FOR TOTAL PROTEIN DETERMINATIONS - BOVINE SERUM-ALBUMIN
    REEDER, DJ
    SCHAFFER, R
    CLINICAL CHEMISTRY, 1977, 23 (06) : 1136 - 1136
  • [29] Preparation and Characterization of Rivastigmine Loaded Human Serum Albumin (HSA) Nanoparticles
    Avachat, Amelia M.
    Oswal, Yogesh M.
    Gujar, Kishor N.
    Shah, Rohit D.
    CURRENT DRUG DELIVERY, 2014, 11 (03) : 359 - 370
  • [30] AN IMPROVED PROCEDURE FOR THE PREPARATION OF HUMAN SERUM ALBUMIN FROM PLACENTAL EXTRACTS
    TAYLOR, HL
    BLOOM, FC
    MCCALL, KB
    HYNDMAN, LA