Modeling and Diagnosis of Induction Machines Operating under Open-Phase Fault

被引:0
|
作者
Kouchih, D. [1 ]
Hachelaf, R. [1 ,2 ]
机构
[1] Univ Saad Dahlab, Automat & Electrotech Dept, Blida, Algeria
[2] Natl Polytech Sch, Automat Control Dept, Algiers, Algeria
关键词
asymmetrical conditions; induction machines; open-phase fault; VARIABLE-SPEED DRIVES; OPEN-SWITCH FAULT; FINITE-ELEMENT; MOTOR; INVERTERS; WAVELET;
D O I
10.1134/S1061830922070063
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper presents a new approach for the modeling and diagnosis of the induction machines (IM) operation under open-phase fault. This fault condition is considered as the most serious one since it produces significant pulsating torque, significant losses, vibration, noise and an excessive heating of the machine. Moreover, it conducts to interturn fault according to the excessive heating of stator windings. As an early detection of open-phase fault is mandatory, particularly attention has been given in the literature to the modeling and diagnosis of IM operating under this faulty condition. In this context, we suggest a new approach for the modeling of the IM operation under open-phase fault using a state model. In asymmetrical star connected IM, the common point voltage differs from zero. As a result, the stator voltages differ from the network simple voltages. For this reason, we use line to line voltages, which are imposed by the network, as inputs in the state model of the machine. Several advantages of the proposed approach can be noted. It can be extended for the analysis of faulty induction machines. In addition, the space and time harmonics can be taken into account. Moreover, magnetic saturation, skin effect, skewed rotor and slotting effects can be integrated in the calculation of the machine inductances. It also offers a good compromise between modeling precision and simulation time. With this approach, open-phase signatures can be extracted on mechanical speed, electromagnetic torque, machine common point voltage, stator currents and fluxes. The obtained results show good agreement with other results which have been obtained using other approaches such as finite elements and symmetrical components methods. The contribution of this work is that the induction machine state equations, machine currents, machine common point voltage are established for open-phase fault condition and a state model is derived for the analysis of the IM operating under this faulty condition. Simulation and experimental results shows the consistency and the applicability of the proposed approach for the modeling of IM operation under Open-phase fault comparatively with previous works.
引用
收藏
页码:617 / 625
页数:9
相关论文
共 50 条
  • [31] Analysis of Dual Three-Phase Induction Machines under Post-Fault Operating Conditions
    Steckel, Richard
    Kremser, Andreas
    Herzog, Hans-Georg
    2020 FIFTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2020,
  • [32] A study on the open-phase current fault diagnosis of motor drive system for electric vehicle
    Lee S.-H.
    Transactions of the Korean Institute of Electrical Engineers, 2019, 68 (07): : 854 - 859
  • [33] An Analysis of Open-Phase Fault in Power Generation Station
    Mohajeryami, Saeed
    Doostan, Milad
    Salami, Zia
    2016 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2016,
  • [34] A New Insight into Six Phase Induction Machine Modeling Under Open Phase Fault Condition
    Deilamani, Mehdi
    Kianinezhad, Reza
    Seifossadat, S. G. H.
    Keramatzade, Mehrdad
    INTERNATIONAL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS & ELECTROMOTION JOINT CONFERENCE, 2011, : 201 - 204
  • [35] Torque Ripple Suppression for Open-End Multi-Phase PMSMs Operating under Open-Phase Faults
    Farshadnia, Mohammad
    Priestley, Matthew
    Cheema, M. A. M.
    Fletcher, John E.
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 731 - 736
  • [36] An Overview of Fault Diagnosis of Industrial Machines Operating Under Variable Speeds
    Madhurjya Dev Choudhury
    Kelly Blincoe
    Jaspreet Singh Dhupia
    Acoustics Australia, 2021, 49 : 229 - 238
  • [37] An Overview of Fault Diagnosis of Industrial Machines Operating Under Variable Speeds
    Choudhury, Madhurjya Dev
    Blincoe, Kelly
    Dhupia, Jaspreet Singh
    ACOUSTICS AUSTRALIA, 2021, 49 (02) : 229 - 238
  • [38] DC-Signal Injection for Stator-Resistance Estimation in Symmetrical Six-Phase Induction Motors Under Open-Phase Fault
    Yepes, Alejandro G.
    Abdel-Majeed, Mahmoud Said
    Che, Hang Seng
    Abdel-Khalik, Ayman Samy
    Ahmed, Shehab
    Doval-Gandoy, Jesus
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (06) : 5444 - 5453
  • [39] Sensorless speed control of a five-phase induction machine under open-phase condition
    Morsy, Ahmed S.
    Abdelkhalik, Ayman S.
    Ahmed, Shehab
    Massoud, Ahmed Mohamed
    JOURNAL OF ENGINEERING-JOE, 2014,
  • [40] A Simple, Fast, and Robust Open-Phase Fault Detection Technique for Six-Phase Induction Motor Drives
    Duran, Mario J.
    Gonzalez-Prieto, Ignacio
    Rios-Garcia, Natalia
    Barrero, Federico
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (01) : 547 - 557