Modeling and Diagnosis of Induction Machines Operating under Open-Phase Fault

被引:0
|
作者
Kouchih, D. [1 ]
Hachelaf, R. [1 ,2 ]
机构
[1] Univ Saad Dahlab, Automat & Electrotech Dept, Blida, Algeria
[2] Natl Polytech Sch, Automat Control Dept, Algiers, Algeria
关键词
asymmetrical conditions; induction machines; open-phase fault; VARIABLE-SPEED DRIVES; OPEN-SWITCH FAULT; FINITE-ELEMENT; MOTOR; INVERTERS; WAVELET;
D O I
10.1134/S1061830922070063
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper presents a new approach for the modeling and diagnosis of the induction machines (IM) operation under open-phase fault. This fault condition is considered as the most serious one since it produces significant pulsating torque, significant losses, vibration, noise and an excessive heating of the machine. Moreover, it conducts to interturn fault according to the excessive heating of stator windings. As an early detection of open-phase fault is mandatory, particularly attention has been given in the literature to the modeling and diagnosis of IM operating under this faulty condition. In this context, we suggest a new approach for the modeling of the IM operation under open-phase fault using a state model. In asymmetrical star connected IM, the common point voltage differs from zero. As a result, the stator voltages differ from the network simple voltages. For this reason, we use line to line voltages, which are imposed by the network, as inputs in the state model of the machine. Several advantages of the proposed approach can be noted. It can be extended for the analysis of faulty induction machines. In addition, the space and time harmonics can be taken into account. Moreover, magnetic saturation, skin effect, skewed rotor and slotting effects can be integrated in the calculation of the machine inductances. It also offers a good compromise between modeling precision and simulation time. With this approach, open-phase signatures can be extracted on mechanical speed, electromagnetic torque, machine common point voltage, stator currents and fluxes. The obtained results show good agreement with other results which have been obtained using other approaches such as finite elements and symmetrical components methods. The contribution of this work is that the induction machine state equations, machine currents, machine common point voltage are established for open-phase fault condition and a state model is derived for the analysis of the IM operating under this faulty condition. Simulation and experimental results shows the consistency and the applicability of the proposed approach for the modeling of IM operation under Open-phase fault comparatively with previous works.
引用
收藏
页码:617 / 625
页数:9
相关论文
共 50 条
  • [1] Modeling and Diagnosis of Induction Machines Operating under Open-Phase Fault
    D. Kouchih
    R. Hachelaf
    Russian Journal of Nondestructive Testing, 2022, 58 : 617 - 625
  • [2] Induction distribution of five-phase induction machines under open-phase fault
    Pereira, Luis Alberto
    Nicol, Guilherme
    Alves Pereira, Luis Fernando
    Perin, Matheus
    ISA TRANSACTIONS, 2020, 96 : 468 - 478
  • [3] Speed Estimation Based on Rotor Slot Harmonics in Multiphase Induction Machines Under Open-Phase Fault
    Yepes, Alejandro G.
    Doval-Gandoy, Jesus
    Baneira, Fernando
    Toliyat, Hamid A.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (09) : 7980 - 7993
  • [4] A New Method for RFOC of Induction Motor Under Open-Phase Fault
    Jannati, M.
    Idris, N. R. N.
    Aziz, M. J. A.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 2530 - 2535
  • [5] Modeling and Control of Three-Phase PMSMs under Open-Phase Fault
    Gaeta, Alberto
    Scelba, Giacomo
    Consoli, Alfio
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 1684 - 1691
  • [6] Load Capability of Multiphase Machines under Normal and Open-Phase Fault Conditions
    Boglietti, A.
    Bojoi, R.
    Rubino, S.
    Cossale, M.
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 242 - 247
  • [7] Modeling and Control of Three-Phase PMSMs Under Open-Phase Fault
    Gaeta, Alberto
    Scelba, Giacomo
    Consoli, Alfio
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (01) : 74 - 83
  • [8] Sensorless Speed Measurement for n-Phase Induction Machines Under Open-Phase Fault by Means of Rotor Slot Harmonics
    Yepes, Alejandro G.
    Doval-Gandoy, Jesus
    Baneira, Fernando
    Toliyat, Hamid
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 836 - 843
  • [9] Vector Control of Three-Phase Induction Motor Under Open-Phase Fault
    Jannati, M.
    Anbaran, S.
    Idris, N. R. N.
    Aziz, M. J. A.
    2013 IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED 2013), 2013, : 105 - 110
  • [10] MODELING AND FAULT DETECTION OF FIVE-PHASE SYNCHRONOUS GENERATOR UNDER OPEN-PHASE FAULT MODE
    Liang, Chenchen
    Benkhoris, Mohamed-Fouad
    Le Claire, Jean-Claude
    Ait-Ahmed, Mourad
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2016, 61 (03): : 250 - 254