'Bone map' for a safe placement of miniscrews generated by computed tomography

被引:26
|
作者
Hernandez, L. C. [1 ]
Montoto, G. [2 ]
Rodriguez, M. Puente [2 ]
Galban, L. [3 ]
Martines, V. [4 ]
机构
[1] Univ Oviedo, Dept Morphol & Cell Biol, Oviedo, Spain
[2] Univ Oviedo, Dept Orthodont, Oviedo, Spain
[3] Univ Salamanca, Dept Dent, E-37008 Salamanca, Spain
[4] Quiron Hosp, Madrid, Spain
关键词
anchorage; bone map; computed tomography; miniscrew; safe areas;
D O I
10.1111/j.1600-0501.2007.01507.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this manuscript is to provide a bone map that can be used as a general guide to determine the areas where miniscrews can be safely anchored. Materials and Methods: Twenty-one computed tomographies (CTs) of maxilla and mandible were taken by the imaging centre ORTOSCAN (R) and two measures were taken: -First, the interradicular space in the mesiodistal plane of the maxillary and mandible teeth with slices taken at 3, 6, and 9 mm from the alveolar crest, in the palatine and vestibular slices. -Second, the interradicular space in the vestibular-lingual direction. Results: We can see that the greatest amount of mesiodistal bone is between the first and second inferior molars on the vestibular side and between the second and first inferior molars on the lingual side, whereas the least amount of bone on the mesiodistal plane is between the inferior incisors on the vestibular side. To determine the length of the miniscrew, we must take into account that the greatest amount of vestibular-lingual bone is between the first and second inferior molar, whereas the least amount is between the central and lateral inferior incisors. Conclusions: Mesiodistal values in vestibular are those that must be considered when inserting the microscrew so as not to damage the dental tissue. Mesiodistal measurements taken in palatal-lingual do not present problems when inserting microscrews.
引用
收藏
页码:576 / 581
页数:6
相关论文
共 50 条
  • [41] Use of computed tomography to define a sacral safe corridor for placement of 2.7 mm cortical screws in feline sacroiliac luxation
    Philp, Helen
    Durand, Alexane
    De Vicente, Felipe
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2018, 20 (06) : 487 - 493
  • [42] Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: Clinical data from 94 implants
    Ersoy, Ahmet Ersan
    Turkyilmaz, Ilser
    Ozan, Oguz
    McGlurnphy, Edwin A.
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (08) : 1339 - 1345
  • [43] The use of computed tomography for screening can be effective and safe
    Giles, John
    Marshall, John
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2008, 69 (01) : 6 - 7
  • [44] Blunt trauma of bone structures of the chest computed tomography vs multidetector computed tomography
    Petrovic, Kosta
    Turkalj, Ivan
    Stojanovic, Sanja
    Vucaj-Cirilovic, Viktorija
    Nikolic, Olivera
    Stojiljkovic, Dragana
    VOJNOSANITETSKI PREGLED, 2013, 70 (08) : 757 - 761
  • [45] Computed tomography and magnetic resonance tomography of the normal temporal bone
    Czerny, C
    Franz, R
    Imhof, H
    RADIOLOGE, 2003, 43 (03): : 200 - 206
  • [46] Evaluation of Maxillary Alveolar Ridge Morphology and Residual Bone for Implant Placement by Cone Beam Computed Tomography (CBCT)
    Valizadeh S.
    Baharestani M.
    Amid R.
    Ahsaie M.G.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (02) : 61 - 71
  • [47] Role of Positron Emission Tomography/Computed Tomography in Bone Malignancies
    Peller, Patrick J.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2013, 51 (05) : 845 - +
  • [48] COMPARISON OF COMPUTED-TOMOGRAPHY AND PLURIDIRECTIONAL TOMOGRAPHY OF THE TEMPORAL BONE
    LUFKIN, R
    BARNI, JJ
    GLEN, W
    MANCUSO, A
    CANALIS, R
    HANAFEE, W
    RADIOLOGY, 1982, 143 (03) : 715 - 718
  • [49] Volumetric Evaluation of Safe Zone for Bone Harvesting From Symphysis Region by Using Cone Beam Computed Tomography
    Altug, Hasan Ayberk
    Coskun, Tugrul
    Kamburoglu, Kivanc
    Zerener, Tamer
    Gulen, Orhan
    Sencimen, Metin
    Ozkan, Aydin
    IMPLANT DENTISTRY, 2016, 25 (06) : 758 - 761
  • [50] Bone Density Development of the Temporal Bone Assessed by Computed Tomography
    Takahashi, Kuniyuki
    Morita, Yuka
    Ohshima, Shinsuke
    Izumi, Shuji
    Kubota, Yamato
    Horii, Arata
    OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : 1445 - 1449