'Bone map' for a safe placement of miniscrews generated by computed tomography

被引:26
|
作者
Hernandez, L. C. [1 ]
Montoto, G. [2 ]
Rodriguez, M. Puente [2 ]
Galban, L. [3 ]
Martines, V. [4 ]
机构
[1] Univ Oviedo, Dept Morphol & Cell Biol, Oviedo, Spain
[2] Univ Oviedo, Dept Orthodont, Oviedo, Spain
[3] Univ Salamanca, Dept Dent, E-37008 Salamanca, Spain
[4] Quiron Hosp, Madrid, Spain
关键词
anchorage; bone map; computed tomography; miniscrew; safe areas;
D O I
10.1111/j.1600-0501.2007.01507.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this manuscript is to provide a bone map that can be used as a general guide to determine the areas where miniscrews can be safely anchored. Materials and Methods: Twenty-one computed tomographies (CTs) of maxilla and mandible were taken by the imaging centre ORTOSCAN (R) and two measures were taken: -First, the interradicular space in the mesiodistal plane of the maxillary and mandible teeth with slices taken at 3, 6, and 9 mm from the alveolar crest, in the palatine and vestibular slices. -Second, the interradicular space in the vestibular-lingual direction. Results: We can see that the greatest amount of mesiodistal bone is between the first and second inferior molars on the vestibular side and between the second and first inferior molars on the lingual side, whereas the least amount of bone on the mesiodistal plane is between the inferior incisors on the vestibular side. To determine the length of the miniscrew, we must take into account that the greatest amount of vestibular-lingual bone is between the first and second inferior molar, whereas the least amount is between the central and lateral inferior incisors. Conclusions: Mesiodistal values in vestibular are those that must be considered when inserting the microscrew so as not to damage the dental tissue. Mesiodistal measurements taken in palatal-lingual do not present problems when inserting microscrews.
引用
收藏
页码:576 / 581
页数:6
相关论文
共 50 条
  • [21] Bone loss evaluation by cone beam computed tomography postdental implant placement: An original research
    Iqbal, Asif
    Vathare, Amit Shivakant
    Karthic, R. Ramkumar
    Pottom, Anupama
    Anitha, A.
    Blsg, Krishna Kumari
    Reddy, Dalli Bharath Simha
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 270 - 272
  • [22] Trabecular volumetric bone mineral density of the occipital bone at preferred screw placement sites measured by quantitative computed tomography
    Moser, Manuel
    Amini, Dominik Adl
    Okano, Ichiro
    Oezel, Lisa
    Shue, Jennifer
    Carrino, John A.
    Sama, Andrew A.
    Cammisa, Frank P.
    Girardi, Federico P.
    Hughes, Alexander P.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (08) : 1909 - 1917
  • [23] Stability of miniscrews with different continuous orthodontic forces as measured by cone-beam computed tomography
    Pongsamart, Prasanpong
    Luppanapornlarp, Suwannee
    Pornprasertsuk-Damrongsri, Suchaya
    Boonpratham, Supatchai
    Santiwong, Peerapong
    ORTHODONTIC WAVES, 2014, 73 (02) : 48 - 54
  • [24] Quantitative evaluation of palatal bone thickness for the placement of orthodontic miniscrews in adults with different facial types
    Wang, Yunji
    Qiu, Ye
    Liu, Henglang
    He, Jinlong
    Fan, Xiaoping
    SAUDI MEDICAL JOURNAL, 2017, 38 (10) : 1051 - 1057
  • [25] Positron emission tomography/computed tomography for bone tumors
    Muheremu, Aikeremujiang
    Niu, Xiaohui
    ONCOLOGY LETTERS, 2015, 9 (02) : 522 - 526
  • [26] Quantitative cone-beam computed tomography evaluation of palatal bone thickness for orthodontic miniscrew placement
    Gracco, Antonio
    Lombardo, Luca
    Cozzani, Mauro
    Siciliani, Giuseppe
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (03) : 361 - 369
  • [27] Proximal femur lag screw placement based on bone mineral density determined by quantitative computed tomography
    Liu, Gang
    Ge, Jun
    Zheng, Xiaohan
    Wu, Cenhao
    Yan, Qi
    Yang, Huilin
    Zou, Jun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 19 (04) : 2720 - 2724
  • [28] Cone Beam Computed Tomography evaluation of palatal bone thickness for miniscrew placement in Down's syndrome
    Diniz-Freitas, M.
    Seoane-Romero, J.
    Fernandez-Varela, M.
    Abeleira, M. T.
    Diz, P.
    Cadarso-Suarez, C.
    Guler, I.
    Limeres, J.
    ARCHIVES OF ORAL BIOLOGY, 2015, 60 (09) : 1333 - 1339
  • [29] Dental Cone Beam Computed Tomography Analyses of the Anterior Maxillary Bone Thickness for Immediate Implant Placement
    Demircan, Sabit
    Demircan, Ela
    IMPLANT DENTISTRY, 2015, 24 (06) : 664 - 668
  • [30] Mapping of Venous Sinus Anatomy and Occipital Bone Thickness for Safe Screw Placement in 100 Patients with 46,200 Standardized Measurements Using Computed Tomography Angiography
    Reisener, Marie-Jacqueline
    Arzani, Artine
    Okano, Ichiro
    Salzmann, Stephan N.
    Rentenberger, Colleen
    Carrino, John A.
    Shue, Jennifer
    Pumberger, Matthias
    Sama, Andrew A.
    Cammisa, Frank P.
    Girardi, Federico P.
    Hughes, Alexander P.
    SPINE, 2022, 47 (05) : E196 - E202